Skip to content
DraconiticResearch
Search Sources API
194,161 studies31 sourcesUpdated 29 min ago
Peer-reviewedCC BY-NCBleeding, Thrombosis and Vascular Biology

PO060 | DISCREPANCY IN FACTOR VIII LEVELS AMONG HEMOPHILIA A CARRIERS: ONE-STAGE VS. CHROMOGENIC ASSAY

Abstract

Background. Hemophilia A (HA) is an X-linked bleeding disorder caused by mutations in the F8 gene. While clinical focus is often on affected males, obligate and symptomatic carriers frequently exhibit reduced Factor VIII (FVIII) activity due to lyonization (X-chromosome inactivation). A significant diagnostic challenge has emerged regarding the "assay discrepancy," where FVIII:C values differ significantly between the One-Stage Clotting Assay (OSA) and the Chromogenic Substrate Assay (CSA). This study investigates the prevalence of this discrepancy in HA carriers and its implications for clinical risk stratification. Methods. A comparative analysis was performed on a cohort of 16 confirmed F8 mutation carriers. FVIII activity was measured using both OSA (based on the activated partial thromboplastin time - aPTT) and CSA (measuring the rate of Factor Xa generation). Discrepancy was defined as a ratio of CSA/OSA < 0.6 or > 1.6. Genetic sequencing was integrated to correlate specific missense mutations with the observed biochemical phenotypes. Results. The results demonstrate that 50% of HA carriers manifest a significant discrepancy between the two assays (Table 1). Analysis of FVIII activity levels revealed a unidirectional discrepancy, characterized exclusively by One-Stage Assay (OSA) values significantly exceeding Chromogenic Substrate Assay (CSA) results (OSA > CSA). No instances of the inverse relationship (CSA > OSA) were observed. This systematic overestimation by the OSA potentially obscures diminished biological clotting activity, posing a significant diagnostic risk. Patients harboring a mild bleeding phenotype may be inaccurately classified as having "hemostatically secure" FVIII levels by traditional clotting assays, despite manifesting a functional deficiency in chromogenic quantification. These findings indicate that OSA-only protocols are insufficient for detecting sub-optimal FVIII function in carriers of "discrepancy-prone" mutations. In such cohorts, clinical bleeding scores (ISTH-BAT) often correlate poorly with OSA-derived FVIII levels. Consequently, the CSA appears to more accurately reflect in vivo hemostatic capacity and the stability of the tenase complex. Conclusions. Relying exclusively on the One-Stage Assay limits the scope of a comprehensive assessment for Hemophilia A carriers, as this methodology may not fully capture the complexities of an individual’s hemostatic profile. The discrepancy between the OSA and the Chromogenic Substrate Assay (CSA) is a tangible biological phenomenon rooted in the molecular stability of Factor VIII and the kinetic integrity of the tenase complex. Consequently, a dual-testing approach is essential for ensuring clinical safety, particularly for symptomatic carriers or those undergoing surgical procedures. This integrated strategy provides a more reliable foundation for personalized prophylactic or on-demand treatment plans, ensuring that clinical decisions are based on the most accurate reflection of in vivo clotting activity.

Related

  1. PO146 | COMPARISON OF COAGULATION AND CHROMOGENIC METHODS IN PHARMACOKINETICS WITH EXTENDED HALF-LIFE FACTOR VIII
    Rebecca Pastorino
    Bleeding, Thrombosis and Vascular BiologyPeer-reviewedCC BY-NCFull textCardiovascular medicineDOAJ
  2. Antidepressant Use and Circulating Lipoprotein(a) Levels: A UK Biobank Analysis Including LPA Variant Carriers
    Iosif Taleb, Courtney Astore, Kavita Praveen +2
    Journal of Lipid ResearchPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossref
  3. Analysis of homocysteine levels in carriers with MMACHC gene variants
    Yi Ding, Yuxin Deng, Haijuan Zhi +5
    Orphanet Journal of Rare DiseasesPeer-reviewedCC BYFull text1 citedGeneral medicineDOAJ
  4. Perioperative management of acute type A aortic dissection using extended half-life factor IX (Alprolix) in a patient with severe hemophilia B: a case report.
    Tessho Kitamura, Yutaro Ryu, Shun Nakaji +1
    General thoracic and cardiovascular surgery casesPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Fidanacogene Elaparvovec Gene Therapy: Budesonide Treatment of a Late Decline in Factor IX Expression in a Patient with Hemophilia B
    Kerstin Herbst, Behnaz Pezeshkpoor, Claudia Klein +6
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
BibTeX
@article{strangio2026po060,
  title = {{PO060 | DISCREPANCY IN FACTOR VIII LEVELS AMONG HEMOPHILIA A CARRIERS: ONE-STAGE VS. CHROMOGENIC ASSAY}},
  author = {Alessandra Strangio},
  journal = {Bleeding, Thrombosis and Vascular Biology},
  year = {2026},
  month = oct,
  url = {https://www.btvb.org/btvb/article/view/876},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - PO060 | DISCREPANCY IN FACTOR VIII LEVELS AMONG HEMOPHILIA A CARRIERS: ONE-STAGE VS. CHROMOGENIC ASSAY
AU  - Alessandra Strangio
PY  - 2026
DA  - 2026/10/26
JO  - Bleeding, Thrombosis and Vascular Biology
UR  - https://www.btvb.org/btvb/article/view/876
AB  - Background. Hemophilia A (HA) is an X-linked bleeding disorder caused by mutations in the F8 gene. While clinical focus is often on affected males, obligate and symptomatic carriers frequently exhibit reduced Factor VIII (FVIII) activity due to lyonization (X-chromosome inactivation). A significant diagnostic challenge has emerged regarding the "assay discrepancy," where FVIII:C values differ significantly between the One-Stage Clotting Assay (OSA) and the Chromogenic Substrate Assay (CSA). This study investigates the prevalence of this discrepancy in HA carriers and its implications for clinical risk stratification. Methods. A comparative analysis was performed on a cohort of 16 confirmed F8 mutation carriers. FVIII activity was measured using both OSA (based on the activated partial thromboplastin time - aPTT) and CSA (measuring the rate of Factor Xa generation). Discrepancy was defined as a ratio of CSA/OSA < 0.6 or > 1.6. Genetic sequencing was integrated to correlate specific missense mutations with the observed biochemical phenotypes. Results. The results demonstrate that 50% of HA carriers manifest a significant discrepancy between the two assays (Table 1). Analysis of FVIII activity levels revealed a unidirectional discrepancy, characterized exclusively by One-Stage Assay (OSA) values significantly exceeding Chromogenic Substrate Assay (CSA) results (OSA > CSA). No instances of the inverse relationship (CSA > OSA) were observed. This systematic overestimation by the OSA potentially obscures diminished biological clotting activity, posing a significant diagnostic risk. Patients harboring a mild bleeding phenotype may be inaccurately classified as having "hemostatically secure" FVIII levels by traditional clotting assays, despite manifesting a functional deficiency in chromogenic quantification. These findings indicate that OSA-only protocols are insufficient for detecting sub-optimal FVIII function in carriers of "discrepancy-prone" mutations. In such cohorts, clinical bleeding scores (ISTH-BAT) often correlate poorly with OSA-derived FVIII levels. Consequently, the CSA appears to more accurately reflect in vivo hemostatic capacity and the stability of the tenase complex. Conclusions. Relying exclusively on the One-Stage Assay limits the scope of a comprehensive assessment for Hemophilia A carriers, as this methodology may not fully capture the complexities of an individual’s hemostatic profile. The discrepancy between the OSA and the Chromogenic Substrate Assay (CSA) is a tangible biological phenomenon rooted in the molecular stability of Factor VIII and the kinetic integrity of the tenase complex. Consequently, a dual-testing approach is essential for ensuring clinical safety, particularly for symptomatic carriers or those undergoing surgical procedures. This integrated strategy provides a more reliable foundation for personalized prophylactic or on-demand treatment plans, ensuring that clinical decisions are based on the most accurate reflection of in vivo clotting activity.
SN  - 2785-5309
ER  -