The impact of functional sagittal pelvic tilt on CT-based hip dysplasia diagnostics in adults: a cross-sectional 3D simulation study
6 affiliations
- 1Department of Orthopedic Surgery, University Medical Center Utrecht, Utrecht
- 2Clinical Orthopedic Research Centre (CORC-mN), Diakonessenhuis, Utrecht/Zeist
- 33D Lab, Division of surgical specialties, University Medical Center Utrecht, Utrecht
- 4Department Biomechanical Engineering, 3ME, TU Delft, Delft
- 5Department of Orthopedics, Sint Maartenskliniek, Nijmegen
- 6Department of Orthopedic Surgery, Leiden University Medical Center, Leiden, The Netherlands
Abstract
Background and purpose: Accurate acetabular coverage assessment is essential for diagnosing adult hip dysplasia. Computed tomography (CT) best evaluates 3-dimensional acetabular morphology but is typically acquired supine, while symptoms arise during weightbearing. This study evaluates how sagittal pelvic tilt affects CT-based acetabular parameters in adults with hip dysplasia and whether pelvic tilt causes clinically relevant measurement changes.
Methods: 3D-models from supine CT of 29 adults with hip dysplasia (lateral center–edge angle (LCEA) ≤ 25°) yielded 39 affected hips. LCEA, inclination (AI), anterior/posterior/horizontal acetabular sector angles (AASA, PASA, HASA), acetabular version (AV), extrusion index (EI), and total and loadbearing coverage were measured. Pelvic tilt was simulated in 5° increments from 30° anterior to 30° posterior around the hip centers and parameters were remeasured in each position. Differences < 2.5° were considered clinically irrelevant.
Results: Median supine LCEA was 21°, AI 50°, AASA 43°. Across −30° to +30° tilt, AASA/loadbearing coverage decreased, PASA/AV increased, LCEA/EI showed parabolic patterns, and HASA/total coverage remained stable. From supine to simulated upright, paired mean differences were: LCEA −1° (95% confidence interval [CI] −2 to 0), AASA −4° (CI −5 to −3), PASA +4° (CI 4 to 5), HASA 0° (CI −1 to 1), AV +4° (CI 3 to 4), AI +1° (CI −1 to 3), EI +2% (CI 0 to 4), total coverage 0% (CI 0 to 0), and loadbearing coverage −2% (CI –2 to –2).
Conclusion: Functional sagittal pelvic tilt resulted in generally small changes in CT-based acetabular measurements in dysplastic hips, which may be clinically relevant in borderline cases, particularly for AASA, PASA, acetabular version, and EI, whereas LCEA and AI were not significantly affected.
Related
- Female Sex Is Independently Associated With Greater Sagittal Tibial Tubercle-Trochlear Groove Distance and Patellar Tilt in High-Grade Trochlear Dysplasia.
- Spinopelvic compensation and functional outcomes after short-segment lumbar fusion in patients with residual sagittal imbalance
- Changes in spinopelvic sagittal parameters and functional outcomes after unilateral microscopic decompression for lumbar spinal stenosis
- Relationship between coronal and sagittal tibial alignment in healthy Japanese adults: A prospective cross-sectional study
- A comprehensive analysis of the association of psychological profiling and sagittal balance parameters with neck pain in a non-deformity cervical spondylosis population: A prospective two-centers cross-sectional study.
BibTeX
@article{husken2026impact,
title = {{The impact of functional sagittal pelvic tilt on CT-based hip dysplasia diagnostics in adults: a cross-sectional 3D simulation study}},
author = {Milou F T HÜSKEN and Fianne LISSENDORP and Joëll MAGRÉ and Koen WILLEMSEN and Harrie WEINANS and Ralph SAKKERS and Jafar NASRABADI and Vahid ARBABI and Joris BEKKERS and Arno M ten HAM and Tom P C SCHLÖSSER and Bart C H van der WAL},
journal = {Acta Orthopaedica},
year = {2026},
month = nov,
doi = {10.2340/17453674.2026.46974},
url = {https://doi.org/10.2340/17453674.2026.46974},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - The impact of functional sagittal pelvic tilt on CT-based hip dysplasia diagnostics in adults: a cross-sectional 3D simulation study
AU - Milou F T HÜSKEN
AU - Fianne LISSENDORP
AU - Joëll MAGRÉ
AU - Koen WILLEMSEN
AU - Harrie WEINANS
AU - Ralph SAKKERS
AU - Jafar NASRABADI
AU - Vahid ARBABI
AU - Joris BEKKERS
AU - Arno M ten HAM
AU - Tom P C SCHLÖSSER
AU - Bart C H van der WAL
PY - 2026
DA - 2026/11/12
JO - Acta Orthopaedica
DO - 10.2340/17453674.2026.46974
UR - https://doi.org/10.2340/17453674.2026.46974
AB - Background and purpose: Accurate acetabular coverage assessment is essential for diagnosing adult hip dysplasia. Computed tomography (CT) best evaluates 3-dimensional acetabular morphology but is typically acquired supine, while symptoms arise during weightbearing. This study evaluates how sagittal pelvic tilt affects CT-based acetabular parameters in adults with hip dysplasia and whether pelvic tilt causes clinically relevant measurement changes. Methods: 3D-models from supine CT of 29 adults with hip dysplasia (lateral center–edge angle (LCEA) ≤ 25°) yielded 39 affected hips. LCEA, inclination (AI), anterior/posterior/horizontal acetabular sector angles (AASA, PASA, HASA), acetabular version (AV), extrusion index (EI), and total and loadbearing coverage were measured. Pelvic tilt was simulated in 5° increments from 30° anterior to 30° posterior around the hip centers and parameters were remeasured in each position. Differences < 2.5° were considered clinically irrelevant. Results: Median supine LCEA was 21°, AI 50°, AASA 43°. Across −30° to +30° tilt, AASA/loadbearing coverage decreased, PASA/AV increased, LCEA/EI showed parabolic patterns, and HASA/total coverage remained stable. From supine to simulated upright, paired mean differences were: LCEA −1° (95% confidence interval [CI] −2 to 0), AASA −4° (CI −5 to −3), PASA +4° (CI 4 to 5), HASA 0° (CI −1 to 1), AV +4° (CI 3 to 4), AI +1° (CI −1 to 3), EI +2% (CI 0 to 4), total coverage 0% (CI 0 to 0), and loadbearing coverage −2% (CI –2 to –2). Conclusion: Functional sagittal pelvic tilt resulted in generally small changes in CT-based acetabular measurements in dysplastic hips, which may be clinically relevant in borderline cases, particularly for AASA, PASA, acetabular version, and EI, whereas LCEA and AI were not significantly affected.
SN - 1745-3674
SN - 1745-3682
ER -