Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 36 min ago
Peer-reviewedCC BY 4.0Critical Care

Using capnography to differentiate airway from gastrointestinal placement of nasogastric tubes: a prospective multicentre diagnostic accuracy study

6 affiliations
  1. 1The Nethersole School of Nursing, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong SAR China
  2. 2Nursing Services Department, Hospital Authority Head Office, Hospital Authority, 147B Argyle Street, Kowloon, Hong Kong SAR China
  3. 3Department of Medicine and Geriatrics, Shatin Hospital, Hospital Authority, 33 A Kung Kok Street, Ma On Shan, Shatin, N.T., Hong Kong SAR China
  4. 4Adult Intensive Care Unit, Queen Mary Hospital, Hospital Authority, 102 Pok Fu Lam Road, Pok Fu Lam, Hong Kong Island, Hong Kong SAR China
  5. 5Alice Ho Miu Ling Nethersole Hospital & Tai Po Hospital, Hospital Authority, 9 Chuen On Road, Tai Po, N.T., Hong Kong SAR China
  6. 6Accident and Emergency Department, Prince of Wales Hospital, Hospital Authority, 30-32 Ngan Shing Street, Shatin, N.T., Hong Kong SAR China

Abstract

Background: Patient safety incident reports and case reports have repeatedly highlighted factors contributing to inadvertent airway placement of nasogastric tubes, including misleading pH readings, insufficiently documented placement checks, and misinterpretation of radiographs. The study aimed to: (i) evaluate the diagnostic performance of capnography compared with radiography for detecting inadvertent airway placement of nasogastric tubes; and (ii) estimate the average cost incurred when radiography is used alone versus when capnography is used in conjunction with radiography.

Methods: A multicentre, prospective, observational diagnostic study was conducted. The diagnostic accuracy of capnography was examined using three end-tidal carbon dioxide thresholds (> 5 mmHg, > 10 mmHg, > 15 mmHg), with radiographic confirmation as the reference standard. For each threshold, true positives, false negatives, true negatives, and false positives were determined. Cost savings per patient were estimated using a bias-corrected and accelerated bootstrapping method with 20,000 replications.

Results: A total of 508 participants were recruited from 39 study sites across 21 hospitals, including medical or geriatric wards, intensive care units, and emergency departments. Most participants (n = 485; 95.5%) had end-tidal carbon dioxide readings ≤ 5 mmHg. Radiography confirmed correct gastric placement in 452 cases (89.0%), with one case (0.2%) of inadvertent airway placement. Estimated cost savings per patient, were HK$210.3, HK$214.5, and HK$217.5 for the three respective end-tidal carbon dioxide thresholds, based on a hypothetical strategy in which radiographic confirmation was performed only when the end-tidal carbon dioxide value exceeded a predefined threshold, compared with a radiography-only strategy in which all patients underwent radiographic confirmation of nasogastric tube placement.

Conclusions: Given the favourable outcomes and the simplicity of capnography measurement, capnography can be considered a first-line tool for excluding airway placement of nasogastric tubes, used alongside pH testing of aspirates.

Trial registration: ClinicalTrials.gov, Number NCT05817864 (Registration date: 18 April 2023).

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s13054-026-06246-9.

Related

  1. Non-contact fingertip video to differentiate dengue haemorrhagic fever in plasma leakage from dengue fever: A prospective proof-of-concept cohort study
    M. H. M. T. S. Perera, S. T. Manamperi, S. A. A. J. M. Athukorala +5
    medRxivPreprintCC BY-NC-NDFull textInfectious diseasemedRxiv
  2. Predictability of symptom changes following hemithyroidectomy due to compression symptoms assessed by specific questionnaires: prospective multicentre study.
    Ervin Beka, Ivan Shabo, David Fornander +2
    BJS openPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaEurope PMC
  3. Vibroacoustic lung therapy and early postoperative oxygenation after cardiac surgery: a multicentre prospective study
    Timur Kapyshev, Marat Shoranov, Zhangeldi Kadirov +5
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Safety and efficiency of the HEART-GP strategy with point-of-care high-sensitivity troponin testing for acute chest pain in out-of-hours primary care: a prospective multicentre diagnostic accuracy study
    I. Melessen, J. C. L. Himmelreich, A. Manten +2
    medRxivPreprintAll rights reservedFull textCardiovascular medicinemedRxiv
  5. Evaluation of the Efficacy and Safety of Combination Therapy of Vamha and Myrha in the Management of PMOS: An Open-Label, Randomized, Multicentre, Comparative, Prospective Clinical Study
    A. Patil, R. Barathe, D. M. Tate +7
    medRxivPreprintAll rights reservedFull textObstetrics, gynaecology & paediatricsmedRxiv
BibTeX
@article{chau2026using,
  title = {{Using capnography to differentiate airway from gastrointestinal placement of nasogastric tubes: a prospective multicentre diagnostic accuracy study}},
  author = {Janita Pak Chun Chau and Danny Wah Kun Tong and Suzanne Hoi Shan Lo and Savina Yee Man Sze and Peter Chi Keung Lai and Josephine Yuen Man Chung and Molly Lai Mei Kwok and Harris Kai Cheong Lam and Ying Hei Fan and Wai Tong Chien and Philip Wing Ping Au and Kai Chow Choi},
  journal = {Critical Care},
  year = {2026},
  month = aug,
  doi = {10.1186/s13054-026-06246-9},
  url = {https://doi.org/10.1186/s13054-026-06246-9},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Using capnography to differentiate airway from gastrointestinal placement of nasogastric tubes: a prospective multicentre diagnostic accuracy study
AU  - Janita Pak Chun Chau
AU  - Danny Wah Kun Tong
AU  - Suzanne Hoi Shan Lo
AU  - Savina Yee Man Sze
AU  - Peter Chi Keung Lai
AU  - Josephine Yuen Man Chung
AU  - Molly Lai Mei Kwok
AU  - Harris Kai Cheong Lam
AU  - Ying Hei Fan
AU  - Wai Tong Chien
AU  - Philip Wing Ping Au
AU  - Kai Chow Choi
PY  - 2026
DA  - 2026/08/14
JO  - Critical Care
DO  - 10.1186/s13054-026-06246-9
UR  - https://doi.org/10.1186/s13054-026-06246-9
AB  - Background: Patient safety incident reports and case reports have repeatedly highlighted factors contributing to inadvertent airway placement of nasogastric tubes, including misleading pH readings, insufficiently documented placement checks, and misinterpretation of radiographs. The study aimed to: (i) evaluate the diagnostic performance of capnography compared with radiography for detecting inadvertent airway placement of nasogastric tubes; and (ii) estimate the average cost incurred when radiography is used alone versus when capnography is used in conjunction with radiography.  Methods: A multicentre, prospective, observational diagnostic study was conducted. The diagnostic accuracy of capnography was examined using three end-tidal carbon dioxide thresholds (> 5 mmHg, > 10 mmHg, > 15 mmHg), with radiographic confirmation as the reference standard. For each threshold, true positives, false negatives, true negatives, and false positives were determined. Cost savings per patient were estimated using a bias-corrected and accelerated bootstrapping method with 20,000 replications.  Results: A total of 508 participants were recruited from 39 study sites across 21 hospitals, including medical or geriatric wards, intensive care units, and emergency departments. Most participants (n = 485; 95.5%) had end-tidal carbon dioxide readings ≤ 5 mmHg. Radiography confirmed correct gastric placement in 452 cases (89.0%), with one case (0.2%) of inadvertent airway placement. Estimated cost savings per patient, were HK$210.3, HK$214.5, and HK$217.5 for the three respective end-tidal carbon dioxide thresholds, based on a hypothetical strategy in which radiographic confirmation was performed only when the end-tidal carbon dioxide value exceeded a predefined threshold, compared with a radiography-only strategy in which all patients underwent radiographic confirmation of nasogastric tube placement.  Conclusions: Given the favourable outcomes and the simplicity of capnography measurement, capnography can be considered a first-line tool for excluding airway placement of nasogastric tubes, used alongside pH testing of aspirates.  Trial registration: ClinicalTrials.gov, Number NCT05817864 (Registration date: 18 April 2023).  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s13054-026-06246-9.
SN  - 1364-8535
SN  - 1466-609X
ER  -