Skip to content
DraconiticResearch
Search Sources API
194,067 studies31 sourcesUpdated 27 min ago
PreprintarXiv licencearXiv

Physical interpretation and limits of photon--dilepton radial-flow tomography

Abstract

Thermal photons and dileptons provide complementary information on the temperature and collective expansion of matter created in relativistic heavy-ion collisions. Their combination has been proposed as an electromagnetic probe of radial flow: a comparatively flow-insensitive dilepton invariant-mass inverse slope is used to infer the photon inverse slope expected without transverse flow and compared with the observed photon slope. Here the physical basis and leading limitation of this construction are examined using a controlled expanding-fireball calculation. The dilepton and flow-free photon inverse slopes are tightly correlated because they respond similarly to changes of the underlying thermal scale, although the numerical relation depends on the spectral window and electromagnetic source. The flow-induced change of the photon inverse slope correlates more strongly with the photon-emission-weighted velocity component along the photon momentum than with a bulk-like radial-flow average. Prethermal source variations can bias the inferred flow-free photon reference and generate apparent flow even when the direct photon spectral-flow signal vanishes, while multiple photon and dilepton windows provide independent response patterns that can help diagnose this source ambiguity. These results clarify both what photon--dilepton radial-flow tomography measures and the source consistency required for its interpretation.

Related

  1. Measurement of the Higgs boson decay to a low-mass dilepton system and a photon in pp collisions at √s = 13 and 13.6 TeV with the ATLAS detector
    Georges Aad, Erlend Aakvaag, Braden Keim Abbott +2,896
    HALPreprintLicence not statedHigh-energy & particle physicsHAL
  2. Neural-network-based material identification in photon-counting computed tomography using region-of-interest spectral features
    A. Miadzvetski, V. Rozhkov, R. Sotenskii +2
    arXivPreprintCC BY-NC-ND 4.0Full textApplied physics & instrumentationarXiv
  3. Quantitative interpretation of Brookfield DV3TLV measurements: shear rate conversion, correction factors, and applicability limits
    A. E. Vasiliev, A. S. Besov, D. O. Andreev
    arXivPreprintarXiv licenceFull textGeophysics & seismologyApplied physics & instrumentationarXiv
  4. Beyond Half-Life Limits: Robust Operator-Level Interpretation of Multi-Isotope Neutrinoless Double-Beta Decay
    K. Ishidoshiro
    arXivPreprintarXiv licenceFull textHigh-energy & particle physicsarXiv
  5. Sensor-aware physical modelling for deep learning-based single-photon imaging
    Yiwei Chen, Xun Lang, Yu Pan
    Optics ExpressPeer-reviewedPublisher termsApplied physics & instrumentationCrossref
BibTeX
@misc{du2026physical,
  title = {{Physical interpretation and limits of photon--dilepton radial-flow tomography}},
  author = {Lipei Du},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.25691},
  eprint = {2609.25691},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.25691},
}
RIS
TY  - UNPB
TI  - Physical interpretation and limits of photon--dilepton radial-flow tomography
AU  - Lipei Du
PY  - 2026
DA  - 2026/09/22
PB  - arXiv
DO  - 10.48550/arxiv.2609.25691
UR  - https://arxiv.org/abs/2609.25691
AB  - Thermal photons and dileptons provide complementary information on the temperature and collective expansion of matter created in relativistic heavy-ion collisions. Their combination has been proposed as an electromagnetic probe of radial flow: a comparatively flow-insensitive dilepton invariant-mass inverse slope is used to infer the photon inverse slope expected without transverse flow and compared with the observed photon slope. Here the physical basis and leading limitation of this construction are examined using a controlled expanding-fireball calculation. The dilepton and flow-free photon inverse slopes are tightly correlated because they respond similarly to changes of the underlying thermal scale, although the numerical relation depends on the spectral window and electromagnetic source. The flow-induced change of the photon inverse slope correlates more strongly with the photon-emission-weighted velocity component along the photon momentum than with a bulk-like radial-flow average. Prethermal source variations can bias the inferred flow-free photon reference and generate apparent flow even when the direct photon spectral-flow signal vanishes, while multiple photon and dilepton windows provide independent response patterns that can help diagnose this source ambiguity. These results clarify both what photon--dilepton radial-flow tomography measures and the source consistency required for its interpretation.
ER  -