An Octahedral Fibrous Constitutive Model for Heart Valve Mechanics and Function
Abstract
Fibrous soft tissues derive their nonlinear mechanical response from networks of extracellular matrix fibers. The organization of fibers and their load-bearing characteristics give rise to strain stiffening, the reverse Poynting effect, and anisotropic mechanical behavior. Motivated by these coupled features, we develop an anisotropic hyperelastic model for fibrous biological tissues that accounts for the contribution of the fiber network under both tensile and compressive deformation. The model uses an octahedral arrangement of fibers embedded in a ground matrix, allowing anisotropy, volume fraction, and pre-stretch to influence the material response. We calibrate the model to experimental data for mitral valve leaflets using an inverse finite element approach that is coupled to automatic differentiation to facilitate efficient parameter calibration. The calibrated model reproduces responses across biaxial, pure-shear, and constrained-uniaxial tests, while separate numerical tests demonstrate its ability to represent substantial volume reduction and the reverse Poynting effect. Using the calibrated model, we investigate how anisotropy and fiber reorientation affect valve deformation under physiological loading. The results show that greater leaflet compliance in the radial direction yields proper valve closure, whereas localized fiber reorientation leads to stress concentrations that may promote progressive functional degradation. Widespread reversal of the preferred material directions, by contrast, prevents closure in the simulated valve. Finally, we examine how fiber pre-stretch and collagen volume fraction affect leaflet strain and contact, finding a stronger response to changes in pre-stretch over the parameter ranges studied.
Related
- Reconstruction of a fibrous pseudo-patella in total knee arthroplasty after patellectomy: a function-preserving strategy via intraoperative soft tissue balancing and postoperative rehabilitation– a case report
- CONSTITUTIVE STIM1L DELETION ALTERS STORE-OPERATED CALCIUM ENTRY KINETICS BUT DOES NOT PERTURB THE DEVELOPMENT AND FUNCTION OF MOUSE SKELETAL MUSCLE
- Nucleated Erythrocytes: Linking Structure, Mechanics, Function, and Stress Responses
- Postpartum Abdominopelvic Stabilization Dysfunction and Bowel Function: A Proposed Mechanistic Model Linking Pressure Control, Visceral Mechanics, Transit, and the Intestinal Environment—A Critical Narrative Review
- The relationship between in-socket mechanics and patient-reported comfort and function, a randomized crossover trial.
BibTeX
@misc{parvez2026octahedral,
title = {{An Octahedral Fibrous Constitutive Model for Heart Valve Mechanics and Function}},
author = {Nishan Parvez and Prashant K. Purohit and Wensi Wu},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2606.04234},
eprint = {2606.04234},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2606.04234},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - An Octahedral Fibrous Constitutive Model for Heart Valve Mechanics and Function
AU - Nishan Parvez
AU - Prashant K. Purohit
AU - Wensi Wu
PY - 2026
DA - 2026/10/11
PB - arXiv
DO - 10.48550/arxiv.2606.04234
UR - https://arxiv.org/abs/2606.04234
AB - Fibrous soft tissues derive their nonlinear mechanical response from networks of extracellular matrix fibers. The organization of fibers and their load-bearing characteristics give rise to strain stiffening, the reverse Poynting effect, and anisotropic mechanical behavior. Motivated by these coupled features, we develop an anisotropic hyperelastic model for fibrous biological tissues that accounts for the contribution of the fiber network under both tensile and compressive deformation. The model uses an octahedral arrangement of fibers embedded in a ground matrix, allowing anisotropy, volume fraction, and pre-stretch to influence the material response. We calibrate the model to experimental data for mitral valve leaflets using an inverse finite element approach that is coupled to automatic differentiation to facilitate efficient parameter calibration. The calibrated model reproduces responses across biaxial, pure-shear, and constrained-uniaxial tests, while separate numerical tests demonstrate its ability to represent substantial volume reduction and the reverse Poynting effect. Using the calibrated model, we investigate how anisotropy and fiber reorientation affect valve deformation under physiological loading. The results show that greater leaflet compliance in the radial direction yields proper valve closure, whereas localized fiber reorientation leads to stress concentrations that may promote progressive functional degradation. Widespread reversal of the preferred material directions, by contrast, prevents closure in the simulated valve. Finally, we examine how fiber pre-stretch and collagen volume fraction affect leaflet strain and contact, finding a stronger response to changes in pre-stretch over the parameter ranges studied.
ER -