Massive transfusion practices and low‐titer group O whole blood utilization before and after implementation in a low‐volume level I trauma center: A six‐year review

  1. 1Department of Pathology and Laboratory Medicine, Transfusion Medicine Division University of Wisconsin–Madison Madison Wisconsin USA
  2. 2Transfusion Services Laboratory University of Wisconsin Hospital and Clinics Madison Wisconsin USA
  3. 3Department of Nursing ‐ Practice Innovation University of Wisconsin Hospital and Clinics Madison Wisconsin USA

Abstract

Background: Low‐titer O whole blood (LTOWB) has been increasingly incorporated into trauma resuscitation and massive transfusion protocols (MTPs). Recent randomized trials have not demonstrated superiority of prehospital LTOWB over component‐based resuscitation, while the utilization and sustainability of LTOWB programs, particularly in low‐volume trauma systems, remain incompletely characterized.

Study Design and Methods: This was a 6‐year review (April 2019–April 2025) of trauma MTPs at a level 1 trauma center with a low MTP frequency. Transfusion service logs, trauma flowsheets, prehospital and electronic medical records were reviewed for product usage, LTOWB utilization and discard patterns, and clinical outcomes.

Results: One hundred and twenty‐five MTPs were identified (122 component‐only and 11 LTOWB‐supported), with predominantly male (70%) and 81% blunt trauma. Component MTPs had a median RBC utilization of 6 units; 45% required ≤1 MTP line. Prehospital LTOWB use was limited: 33% of units were transfused, and only 2 of 13 patients requiring an MTP received prehospital LTOWB. LTOWB‐supported MTPs typically issued 10 units, and most patients received 1–2 units. Of 524 LTOWB units procured during the first 6 months, 201 were transfused and 323 discarded (62%), with a peak discard rate of 81% early in rollout. Overall, 30‐day mortality was 54%, and 25% occurred within 4 h.

Conclusions: LTOWB use was limited, and early wastage was substantial. LTOWB implementation in low‐volume centers should align inventory and protocols with clinical demand; stewardship measures may reduce waste and improve sustainability.

Related

  1. BASELINE ASSESSMENT OF TRANSFUSION EFFICIENCY BEFORE PATIENT BLOOD MANAGEMENT IMPLEMENTATION IN A TRAUMA AND ORTHOPEDICS HOSPITAL IN MEXICO
    Carolain ULLRICH GARCIA, Juan Carlos SANCHÉZ SERRANO
    Hematology, Transfusion and Cell TherapyPeer-reviewedCC BYFull textEndocrinology & metabolismDOAJ
  2. Massive Transfusion-Associated Osmotic Demyelination Syndrome After Liver Transplantation: A Case Report and Retrospective Estimate of the Sodium Load
    Zong-Ruei Wong, Yen-Cheng Chen, Chia-Ling Lee
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. ABO Nonidentical Transfusions and Mortality in Patients Undergoing Massive Transfusion Protocol
    Neil Blumberg, Kelly Henrichs, Debra Masel +7
    JAMA SurgeryPeer-reviewedLicence not statedFull textGeneral medicinePMC
  4. Sex and mechanism‐specific differences in outcomes following massive transfusion in trauma: A meta‐analysis
    Gena V. Topper, Erin Major, Siddhi Shah +8
    TransfusionPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  5. Transfusion practices, thresholds, and complications in pediatric oncology patients: a single-center prospective longitudinal observational study
    Büşra Tunalı Özcan, Sonay İncesoy Özdemir, Handan Dinçaslan +6
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{onyenekwu2026massive,
  title = {{Massive transfusion practices and low‐titer group O whole blood utilization before and after implementation in a low‐volume level I trauma center: A six‐year review}},
  author = {Chinelo P. Onyenekwu and Debra M. Lehman and Brittany Trower and Paula Woywod and Joseph P. Connor},
  journal = {Transfusion},
  year = {2026},
  month = sep,
  doi = {10.1111/trf.70409},
  url = {https://doi.org/10.1111/trf.70409},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Massive transfusion practices and low‐titer group O whole blood utilization before and after implementation in a low‐volume level I trauma center: A six‐year review
AU  - Chinelo P. Onyenekwu
AU  - Debra M. Lehman
AU  - Brittany Trower
AU  - Paula Woywod
AU  - Joseph P. Connor
PY  - 2026
DA  - 2026/09/26
JO  - Transfusion
DO  - 10.1111/trf.70409
UR  - https://doi.org/10.1111/trf.70409
AB  - Background: Low‐titer O whole blood (LTOWB) has been increasingly incorporated into trauma resuscitation and massive transfusion protocols (MTPs). Recent randomized trials have not demonstrated superiority of prehospital LTOWB over component‐based resuscitation, while the utilization and sustainability of LTOWB programs, particularly in low‐volume trauma systems, remain incompletely characterized.  Study Design and Methods: This was a 6‐year review (April 2019–April 2025) of trauma MTPs at a level 1 trauma center with a low MTP frequency. Transfusion service logs, trauma flowsheets, prehospital and electronic medical records were reviewed for product usage, LTOWB utilization and discard patterns, and clinical outcomes.  Results: One hundred and twenty‐five MTPs were identified (122 component‐only and 11 LTOWB‐supported), with predominantly male (70%) and 81% blunt trauma. Component MTPs had a median RBC utilization of 6 units; 45% required ≤1 MTP line. Prehospital LTOWB use was limited: 33% of units were transfused, and only 2 of 13 patients requiring an MTP received prehospital LTOWB. LTOWB‐supported MTPs typically issued 10 units, and most patients received 1–2 units. Of 524 LTOWB units procured during the first 6 months, 201 were transfused and 323 discarded (62%), with a peak discard rate of 81% early in rollout. Overall, 30‐day mortality was 54%, and 25% occurred within 4 h.  Conclusions: LTOWB use was limited, and early wastage was substantial. LTOWB implementation in low‐volume centers should align inventory and protocols with clinical demand; stewardship measures may reduce waste and improve sustainability.
SN  - 0041-1132
SN  - 1537-2995
ER  -