Skip to content
DraconiticResearch
Search Sources API
190,851 studies31 sourcesUpdated 31 min ago
Peer-reviewedCC BY 4.0PLOS One

The impact of robot-assisted frameless brain biopsy on performance differences between junior and senior neurosurgeons

  1. 1Department of Neurosurgery, Technical University Hospital of Munich, TUM School of Medicine and Health, Munich, Germany
  2. 2Department of diagnostic and interventional Neuroradiology, Technical University Hospital of Munich, TUM School of Medicine and Health, Munich, Germany
  3. 3Department of Pathology and Neuropathology, Technical University Hospital of Munich, TUM School of Medicine and Health, Munich, Germany

Abstract

Objective: Frameless stereotactic brain biopsy is a standardized and routinely performed neurosurgical procedure, frequently carried out by residents under supervision in academic centers. Robot-assisted (RA) guidance has been introduced to standardize workflow and reduce operator-dependent variability. This study investigates whether RA frameless biopsy reduces experience-related performance differences between residents and attending neurosurgeons compared with a manually operated frameless system (MFS). Methods: We performed a retrospective, non-randomized cohort study of consecutive patients undergoing RA frameless stereotactic brain biopsy for intracranial lesions at a tertiary academic center between 2021 and 2025. Outcomes included perioperative complications, diagnostic yield, and operative time, stratified by surgeon experience level (residents vs. attendings). Results were compared with those of a cohort operated with a MFS. Results: A total of 98 procedures were analyzed (49 RA, 49 MFS). Across the entire cohort, total operative time was longer with RA than with MFS (115.6 ± 34.1 vs. 97.9 ± 27.2 minutes; p = 0.0036), primarily due to longer setup times. Diagnostic yield and complication rates were comparable between systems. Importantly, subgroup analysis demonstrated that residents using RA achieved operative times, diagnostic yield, and complication rates comparable to attending surgeons. In the MFS cohort, total operative time did not differ significantly between residents and attendings. Conclusions: RA-assisted biopsy was associated with comparable diagnostic accuracy and safety relative to MFS. Robotic assistance was associated with smaller observed differences in operative efficiency between residents and attending surgeons, suggesting a potential role in bridging experience-related performance differences during neurosurgical training.

Related

  1. Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study
    Wei-Cheng Tseng, Ching-Heng Lin, Yu-Tsung Lin +6
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Impact evaluation of Lean Healthcare in emergency departments: evidence from a large-scale Brazilian initiative using difference-in-differences
    F. A. S. de Araujo, J. N. R. Ikawa, A. d. S. Lima +2
    medRxivPreprintAll rights reservedFull textEpidemiology & public healthmedRxiv
  3. Position-specific differences in match performance of elite U-17 soccer players using GPS-derived external load data: focus on forwards and defenders
    Chulsoon Choi, Hoseong Lee, Kwangjin Lee
    Physical activity and nutritionPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  4. Sex Differences in the Impact of Allosensitization on Waitlist Access and Post-Transplant Outcomes in Adults with Congenital Heart Disease
    A. Joseph, K. Kearney, C. Henricks +11
    medRxivPreprintAll rights reservedFull textSurgery & anaesthesiamedRxiv
  5. Impact of Social Determinants of Health in Early Pregnancy on Racial and Ethnic Differences in Post-pregnancy Cardiovascular Health
    X. Huang, L. C. Petito, L. M. Yee +17
    medRxivPreprintAll rights reservedFull textEpidemiology & public healthmedRxiv
BibTeX
@article{albrecht2026impact,
  title = {{The impact of robot-assisted frameless brain biopsy on performance differences between junior and senior neurosurgeons}},
  author = {Carolin Albrecht and Tobias Mahler and Viktor M. Eisenkolb and Benedikt Wiestler and Claire Delbridge and Chiara Negwer and Bernhard Meyer and Arthur Wagner},
  journal = {PLOS One},
  year = {2026},
  month = nov,
  doi = {10.1371/journal.pone.0362271},
  url = {https://doi.org/10.1371/journal.pone.0362271},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - The impact of robot-assisted frameless brain biopsy on performance differences between junior and senior neurosurgeons
AU  - Carolin Albrecht
AU  - Tobias Mahler
AU  - Viktor M. Eisenkolb
AU  - Benedikt Wiestler
AU  - Claire Delbridge
AU  - Chiara Negwer
AU  - Bernhard Meyer
AU  - Arthur Wagner
PY  - 2026
DA  - 2026/11/05
JO  - PLOS One
DO  - 10.1371/journal.pone.0362271
UR  - https://doi.org/10.1371/journal.pone.0362271
AB  - Objective: Frameless stereotactic brain biopsy is a standardized and routinely performed neurosurgical procedure, frequently carried out by residents under supervision in academic centers. Robot-assisted (RA) guidance has been introduced to standardize workflow and reduce operator-dependent variability. This study investigates whether RA frameless biopsy reduces experience-related performance differences between residents and attending neurosurgeons compared with a manually operated frameless system (MFS). Methods: We performed a retrospective, non-randomized cohort study of consecutive patients undergoing RA frameless stereotactic brain biopsy for intracranial lesions at a tertiary academic center between 2021 and 2025. Outcomes included perioperative complications, diagnostic yield, and operative time, stratified by surgeon experience level (residents vs. attendings). Results were compared with those of a cohort operated with a MFS. Results: A total of 98 procedures were analyzed (49 RA, 49 MFS). Across the entire cohort, total operative time was longer with RA than with MFS (115.6 ± 34.1 vs. 97.9 ± 27.2 minutes; p = 0.0036), primarily due to longer setup times. Diagnostic yield and complication rates were comparable between systems. Importantly, subgroup analysis demonstrated that residents using RA achieved operative times, diagnostic yield, and complication rates comparable to attending surgeons. In the MFS cohort, total operative time did not differ significantly between residents and attendings. Conclusions: RA-assisted biopsy was associated with comparable diagnostic accuracy and safety relative to MFS. Robotic assistance was associated with smaller observed differences in operative efficiency between residents and attending surgeons, suggesting a potential role in bridging experience-related performance differences during neurosurgical training.
SN  - 1932-6203
ER  -