Concurrent Classification of Pseudomonas aeruginosa Occurrence From Routine Municipal Swimming‐Pool Monitoring Data: An Explainable Machine‐Learning Proof‐of‐Concept With Grouped Validation
- 1Department of Public Health, School of Medicine University of Patras Patras Greece
Abstract
Routine swimming‐pool surveillance may support detection‐oriented screening, but rare positives and repeated sampling complicate model validation. This retrospective study analyzed 453 samples (37 occurrence‐positive) from four chlorinated pools in two Greek facilities (2022–2025). Random forest, logistic regression, gradient boosting, and extra trees were evaluated using concurrent monitoring variables, physicochemical predictors and previous‐sample information. Row‐level, leave‐one‐pool‐out, leave‐one‐facility‐out and temporal validation were compared with a residual‐chlorine‐only baseline. Full‐monitoring random forest achieved PR‐AUC 0.532 within the network, decreasing to 0.386 for held‐out pools and 0.157 for a held‐out facility; corresponding logistic‐regression values were 0.525 and 0.326. Residual chlorine alone achieved PR‐AUC 0.452, with no model significantly outperforming it. Previous‐sample predictors provided no convincing early‐warning signal. Screening thresholds yielded substantial false alerts. These results support exploratory concurrent classification, not prospective warning or deployment readiness, and highlight the need for independent multifacility validation. Machine‐learning models classified Pseudomonas aeruginosa occurrence from routine swimming‐pool monitoring data within the observed network, but performance fell in pools and facilities not used for training, and no model clearly outperformed residual chlorine alone. Previous‐sample data gave no convincing early warning, so prospective multifacility validation is needed.
Related
- Tracking Aeromonas caviae and Pseudomonas aeruginosa in a mixed-use catchment with source attribution, health hazards, and microbial mixing assessments
- Enabling and enhancing anaerobic synthesis of rhamnolipids from glucose by an oil reservoir-derived Pseudomonas aeruginosa strain.
- Explainable quantum inspired LSTM model for water quality classification in fishponds
- An explainable swarm-optimized hybrid GRU–Transformer framework with wavelet-based spatial–temporal feature modeling and activation function analysis for rainfall classification across Pakistan’s climatic regimes
- Concurrent use of NaHCO3 and NH4Cl for synthesis of ZnO–Al2O3 nanocomposite and investigation of its adsorption property
BibTeX
@article{palaiologou2026concurrent,
title = {{Concurrent Classification of Pseudomonas aeruginosa Occurrence From Routine Municipal Swimming‐Pool Monitoring Data: An Explainable Machine‐Learning Proof‐of‐Concept With Grouped Validation}},
author = {Athanasia Palaiologou and Maria Athanasiou and Apostolos Vantarakis},
journal = {Water Environment Research},
year = {2026},
month = nov,
doi = {10.1002/wer.70653},
url = {https://doi.org/10.1002/wer.70653},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Concurrent Classification of Pseudomonas aeruginosa Occurrence From Routine Municipal Swimming‐Pool Monitoring Data: An Explainable Machine‐Learning Proof‐of‐Concept With Grouped Validation
AU - Athanasia Palaiologou
AU - Maria Athanasiou
AU - Apostolos Vantarakis
PY - 2026
DA - 2026/11/11
JO - Water Environment Research
DO - 10.1002/wer.70653
UR - https://doi.org/10.1002/wer.70653
AB - Routine swimming‐pool surveillance may support detection‐oriented screening, but rare positives and repeated sampling complicate model validation. This retrospective study analyzed 453 samples (37 occurrence‐positive) from four chlorinated pools in two Greek facilities (2022–2025). Random forest, logistic regression, gradient boosting, and extra trees were evaluated using concurrent monitoring variables, physicochemical predictors and previous‐sample information. Row‐level, leave‐one‐pool‐out, leave‐one‐facility‐out and temporal validation were compared with a residual‐chlorine‐only baseline. Full‐monitoring random forest achieved PR‐AUC 0.532 within the network, decreasing to 0.386 for held‐out pools and 0.157 for a held‐out facility; corresponding logistic‐regression values were 0.525 and 0.326. Residual chlorine alone achieved PR‐AUC 0.452, with no model significantly outperforming it. Previous‐sample predictors provided no convincing early‐warning signal. Screening thresholds yielded substantial false alerts. These results support exploratory concurrent classification, not prospective warning or deployment readiness, and highlight the need for independent multifacility validation. Machine‐learning models classified Pseudomonas aeruginosa occurrence from routine swimming‐pool monitoring data within the observed network, but performance fell in pools and facilities not used for training, and no model clearly outperformed residual chlorine alone. Previous‐sample data gave no convincing early warning, so prospective multifacility validation is needed.
SN - 1061-4303
SN - 1554-7531
ER -