Skip to content
DraconiticResearch
Search Sources API
178,033 studies31 sourcesUpdated 42 min ago
Peer-reviewedCC BY 4.0IEEE Transactions on Instrumentation and Measurement

A Systematic Measurement Study of Magnetoresistance Sensor Selection and Differential Configuration for Magnetic Nanoparticle Quantification

Abstract

Magnetic nanoparticles (MNPs) are widely used in biomagnetic sensing and bioassays, where accurate and reliable concentration quantification is often required. Relaxation-based magnetic detection exploits the nonlinear magnetization dynamics of MNPs and is commonly employed to probe particle mobility and bio-binding effects; under controlled excitation, the harmonic magnetic response can also be used for concentration measurement. Usually, the pickup element consists of a wound coil collinearly aligned with the excitation source. While conventional multiturn coil-based magnetic particle spectroscopy (MPS) detection offers high sensitivity, its geometry can constrain flowthrough or continuous liquid-phase measurements. In this work, we present a systematic experimental evaluation of giant magnetoresistance (GMR) and tunnel magnetoresistance (TMR) sensors evaluated in three different measurement configurations: single, differential horizontal, and differential vertical. The setup is operated in an anti-Helmholtz configuration. Multiple commercially available magnetoresistance (MR) sensors with different intrinsic sensitivities and dynamic ranges were investigated under a unified excitation, conditioning, and lock-in processing framework. Measurement performances were assessed via concentration-sweep experiments of a 100-nm MNP dilution series by calculating sensitivity, linearity, signal-to-noise ratio (SNR), and repeatability quantified by the coefficient of variation (CV). As a signal, the first, third, and fifth harmonics were analyzed, where the first harmonic amplitude and phase change provided the most robust and monotonic concentration dependence and was therefore used for performance comparison. The results demonstrate sensorlevel tradeoffs between intrinsic responsivity, usable dynamic range, and measurement uncertainty, while vertical differential pairing consistently improves detectability relative to horizontal configuration within the anti-Helmholtz geometry. The presented framework provides practical guidance for the design and integration of MR sensors in compact relaxation-based biomagnetic sensing systems.

Related

  1. Measurement of tZq inclusive and differential cross-sections in pp collisions at √s = 13 TeV with the ATLAS detector
    Georges Aad, Erlend Aakvaag, Braden Keim Abbott +2,898
    HALPreprintLicence not statedHigh-energy & particle physicsHAL
  2. Multi-Differential DVCS Cross Section Measurement on the Proton in the Valence Region with CLAS12
    S Lee, T.B Hayward, L Elouadrhiri +138
    HALPreprintLicence not statedNuclear physicsHAL
  3. A High- and Variable-Dimensional Measurement of the Z+jets Differential Cross Section with the ATLAS Experiment and Artificial Intelligence
    Kevin Greif
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
  4. Differential measurement of global polarization of Λ, Ξ, and Ω hyperons in Au+Au collisions at √(sNN)=7.7--27 GeV from the RHIC Beam Energy Scan-II
    The STAR Collaboration
    arXivPreprintCC BY-NC-ND 4.0Full textNuclear physicsarXiv
  5. Measurement of the forward angle 12C+12C fragmentation differential cross sections at 62 MeV/nucleon
    G Guo, G Casini, B.H Sun +31
    Phys.Rev.CPeer-reviewedCC BY 4.0Full textNuclear physicsHALarXiv
BibTeX
@article{pei2026systematic,
  title = {{A Systematic Measurement Study of Magnetoresistance Sensor Selection and Differential Configuration for Magnetic Nanoparticle Quantification}},
  author = {Peggy Xinyu Pei and Yannick Dusch and Fabio Aldo Kraft and Abdelkrim Talbi and Martina Gerken},
  journal = {IEEE Transactions on Instrumentation and Measurement},
  year = {2026},
  month = oct,
  doi = {10.1109/tim.2026.3742155},
  url = {https://hal.science/hal-05836658v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - A Systematic Measurement Study of Magnetoresistance Sensor Selection and Differential Configuration for Magnetic Nanoparticle Quantification
AU  - Peggy Xinyu Pei
AU  - Yannick Dusch
AU  - Fabio Aldo Kraft
AU  - Abdelkrim Talbi
AU  - Martina Gerken
PY  - 2026
DA  - 2026/10/23
JO  - IEEE Transactions on Instrumentation and Measurement
DO  - 10.1109/tim.2026.3742155
UR  - https://hal.science/hal-05836658v1
AB  - Magnetic nanoparticles (MNPs) are widely used in biomagnetic sensing and bioassays, where accurate and reliable concentration quantification is often required. Relaxation-based magnetic detection exploits the nonlinear magnetization dynamics of MNPs and is commonly employed to probe particle mobility and bio-binding effects; under controlled excitation, the harmonic magnetic response can also be used for concentration measurement. Usually, the pickup element consists of a wound coil collinearly aligned with the excitation source. While conventional multiturn coil-based magnetic particle spectroscopy (MPS) detection offers high sensitivity, its geometry can constrain flowthrough or continuous liquid-phase measurements. In this work, we present a systematic experimental evaluation of giant magnetoresistance (GMR) and tunnel magnetoresistance (TMR) sensors evaluated in three different measurement configurations: single, differential horizontal, and differential vertical. The setup is operated in an anti-Helmholtz configuration. Multiple commercially available magnetoresistance (MR) sensors with different intrinsic sensitivities and dynamic ranges were investigated under a unified excitation, conditioning, and lock-in processing framework. Measurement performances were assessed via concentration-sweep experiments of a 100-nm MNP dilution series by calculating sensitivity, linearity, signal-to-noise ratio (SNR), and repeatability quantified by the coefficient of variation (CV). As a signal, the first, third, and fifth harmonics were analyzed, where the first harmonic amplitude and phase change provided the most robust and monotonic concentration dependence and was therefore used for performance comparison. The results demonstrate sensorlevel tradeoffs between intrinsic responsivity, usable dynamic range, and measurement uncertainty, while vertical differential pairing consistently improves detectability relative to horizontal configuration within the anti-Helmholtz geometry. The presented framework provides practical guidance for the design and integration of MR sensors in compact relaxation-based biomagnetic sensing systems.
SN  - 0018-9456
ER  -