Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 35 min ago
Peer-reviewedCC BYDiagnostics (Basel, Switzerland)

Enhancing Medical Students' Disease Detection Skills: Leveraging Artificial Intelligence Software for Diagnosing Developmental Dysplasia Using Ultrasound Imaging.

6 affiliations
  1. 1Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry, Seoul 03722, Republic of Korea.
  2. 2Medical Course, Keimyung University School of Medicine, Daegu 42601, Republic of Korea.
  3. 3Department of Medical Informatics, Keimyung University School of Medicine, Daegu 42601, Republic of Korea.
  4. 4Department of Anatomy, Keimyung University School of Medicine, Daegu 42601, Republic of Korea.
  5. 5Department of Orthopedics, Keimyung University Dongsan Medical Center, Daegu 42601, Republic of Korea.
  6. 6MaiT Co., Ltd., Daegu 41931, Republic of Korea.

Abstract

Background: Ultrasound is the gold standard for the screening of developmental dysplasia of the hip (DDH). However, there are several problems in overcoming the learning curve of technical skills required to detect DDH using ultrasound. Thus, several attempts have been made to assist in the detection of DDH using artificial intelligence (AI) software (SW). This study aimed to evaluate the efficacy of AI in DDH ultrasound screening to aid medical students in the diagnosis of DDH. Method: A Mask R-CNN-based detection model was developed to identify six key points and measure the alpha and beta angles, as well as containment, following Graf's method. Fifty-three second-year medical students assessed 38 DDH screening ultrasound images from 28 patients twice: first through self-measurement after brief training and then using AI-assisted measurement, where key points were refined based on AI predictions. The gold standard for comparison was the measurement performed by an experienced orthopedic surgeon. Results: AI assistance significantly improved agreement with the expert reference for all three measurements. The proportion of students classified in the excellent agreement category increased from 26.4% to 81.1% for the alpha angle, from 67.9% to 86.8% for the beta angle, and from 56.6% to 84.9% for containment. The mean ICC increased from 0.593 to 0.855 for the alpha angle, from 0.760 to 0.892 for the beta angle, and from 0.722 to 0.882 for containment. Wilcoxon signed-rank tests demonstrated significant improvements in all three measurements (all p < 0.001). Conclusions: AI-assisted ultrasound measurement may improve agreement with expert measurements among novice users assessing DDH. This approach may have potential as a supportive tool for DDH screening and educational training by reducing the learning curve associated with ultrasound-based measurement.

Related

  1. Leveraging Artificial Intelligence in Healthcare in Cambodia: Enhancing Access and Patient Outcomes.
    Sokchan Lorn, Yanvary Chhon, Techly San +1
    Public health challengesPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
  2. Artificial intelligence-based prostate cancer risk stratification via large-scale ultrasound images paired with histopathology
    Qiong Zhang, Qiang Lu, Yu Liang +3
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  3. Validating Artificial Intelligence Guidance for Ultrasound Acquisition and Remote Interpretation
    T. Maldonado, S. Muluk, P. Rali +14
    medRxivPreprintAll rights reservedFull textMedical imaging & radiologymedRxiv
  4. Ensuring Safe and Responsible Use of Artificial Intelligence in Medical Imaging: Pitfalls and Practical Solutions through the Lens of Obstetric Ultrasound.
    Rishika Chanian, Ramachandran Thiruvengadam, Bapu Koundinya Desiraju
    The Indian journal of radiology & imagingPeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthEurope PMC
  5. Artificial intelligence for ultrasound-based differentiation of soft tissue liposarcoma from benign masses.
    YuKun Deng, Chengjia Qu, Yi Cao +8
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{heo2026enhancing,
  title = {{Enhancing Medical Students' Disease Detection Skills: Leveraging Artificial Intelligence Software for Diagnosing Developmental Dysplasia Using Ultrasound Imaging.}},
  author = {Yu-Ran Heo and Jun-Chae Lee and Yeon-Kyoung Ko and Seung-Bo Lee and Jae-Ho Lee and Si-Wook Lee},
  journal = {Diagnostics (Basel, Switzerland)},
  year = {2026},
  month = sep,
  doi = {10.3390/diagnostics16193093},
  url = {https://europepmc.org/article/MED/42882248},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Enhancing Medical Students' Disease Detection Skills: Leveraging Artificial Intelligence Software for Diagnosing Developmental Dysplasia Using Ultrasound Imaging.
AU  - Yu-Ran Heo
AU  - Jun-Chae Lee
AU  - Yeon-Kyoung Ko
AU  - Seung-Bo Lee
AU  - Jae-Ho Lee
AU  - Si-Wook Lee
PY  - 2026
DA  - 2026/09/24
JO  - Diagnostics (Basel, Switzerland)
DO  - 10.3390/diagnostics16193093
UR  - https://europepmc.org/article/MED/42882248
AB  - Background: Ultrasound is the gold standard for the screening of developmental dysplasia of the hip (DDH). However, there are several problems in overcoming the learning curve of technical skills required to detect DDH using ultrasound. Thus, several attempts have been made to assist in the detection of DDH using artificial intelligence (AI) software (SW). This study aimed to evaluate the efficacy of AI in DDH ultrasound screening to aid medical students in the diagnosis of DDH. Method: A Mask R-CNN-based detection model was developed to identify six key points and measure the alpha and beta angles, as well as containment, following Graf's method. Fifty-three second-year medical students assessed 38 DDH screening ultrasound images from 28 patients twice: first through self-measurement after brief training and then using AI-assisted measurement, where key points were refined based on AI predictions. The gold standard for comparison was the measurement performed by an experienced orthopedic surgeon. Results: AI assistance significantly improved agreement with the expert reference for all three measurements. The proportion of students classified in the excellent agreement category increased from 26.4% to 81.1% for the alpha angle, from 67.9% to 86.8% for the beta angle, and from 56.6% to 84.9% for containment. The mean ICC increased from 0.593 to 0.855 for the alpha angle, from 0.760 to 0.892 for the beta angle, and from 0.722 to 0.882 for containment. Wilcoxon signed-rank tests demonstrated significant improvements in all three measurements (all p < 0.001). Conclusions: AI-assisted ultrasound measurement may improve agreement with expert measurements among novice users assessing DDH. This approach may have potential as a supportive tool for DDH screening and educational training by reducing the learning curve associated with ultrasound-based measurement.
SN  - 2075-4418
ER  -