A dual-stage self-attention hybrid convolutional neural network-gated recurrent unit architecture for real-time power quality disturbance diagnosis

Abstract

The increased adoption of the smart grid (SG) infrastructure to overcome the limitations of traditional grid have faced growing challenges for real-time monitoring and classification of features due to the complexity and dynamic nature of power quality disturbances (PQDs). In particular, when PQDs overlap each other, traditional approaches relying on signal processing techniques tend to lose the dynamic, non-periodic characteristics which define certain PQDs. In this proposed work, a novel dual-stage hybrid architecture based on convolutional neural networks (CNNs) and gated recurrent units (GRUs) augmented by self-attention at both stages for real-time high performance PQD classification is presented. This novel hybrid architecture is allows for spatial and temporal feature extraction from electrical power signals, overcoming the weaknesses encountered in traditional approaches. In contrast to previous models that consider either local or sequential patterns independently, the proposed architecture combines both techniques enabling a more robust and computationally-efficient architecture demonstrates software-level real-time inference (21 ms) and provides a computationally efficient architecture suitable for future embedded deployment. The experimental outcomes on the benchmark databases compared to the state-of-the-art convolutional neural network-long short-term memory (CNN-LSTM) architecture offers improved execution time of 21 ms and a classification accuracy of 98.6%. It also outperforms both traditional CNN architecture with improved latency and high accuracy proposing it as a viable alternative for smart grid use cases like phasor measurement units (PMUs), microcontroller-based devices, etc.

Related

  1. Improved Dung Beetle Optimizer–Tuned Convolutional–Recurrent Temporal Self-Attention Network for Multi-Horizon Traffic Speed Forecasting
    Jiwu Tang, Linchao An, Haifeng Liu +1
    Sensors (Basel, Switzerland)Peer-reviewedCC BYFull textEurope PMC
  2. Interpretable attention-deficit hyperactivity disorder diagnosis from functional magnetic resonance imaging via hybrid convolutional neural network–transformer learning and multi-level graph-based comprehensibility
    R. Harini, O. Uma Maheswari, K. Lakshmi Priya
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textPsychiatry & mental healthCrossref
  3. Rolling bearing fault diagnosis method based on dual attention multi-scale convolutional network
    Yamei Zhang, Xiaohu Liu
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePLOS
  4. COVLIAS 3.5: integration of attention-based segmentation technique with fuzzy dilated convolutional neural networks for improved classification of chest X-ray scans for multiclass pneumonia diagnosis
    Arun K. Dubey, Achin Jain, Shruti Vashist +4
    Scientific ReportsPeer-reviewedCC BYFull textMedical imaging & radiologyDOAJ
  5. Asymptotic mixed graph convolutional with trend-aware self-attention networks for traffic flow forecasting
    Hongyan Wang
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCrossref
BibTeX
@article{samanta2026dualstage,
  title = {{A dual-stage self-attention hybrid convolutional neural network-gated recurrent unit architecture for real-time power quality disturbance diagnosis}},
  author = {Indu Sekhar Samanta and Buddhadeva Sahoo and Pravat Kumar Rout and Sarthak Mohanty and Sumit Kumar Jha and Kunjabihari Swain and Murthy Cherukuri},
  journal = {Scientific Reports},
  year = {2026},
  month = oct,
  doi = {10.1038/s41598-026-70345-4},
  url = {https://www.nature.com/articles/s41598-026-70345-4},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - A dual-stage self-attention hybrid convolutional neural network-gated recurrent unit architecture for real-time power quality disturbance diagnosis
AU  - Indu Sekhar Samanta
AU  - Buddhadeva Sahoo
AU  - Pravat Kumar Rout
AU  - Sarthak Mohanty
AU  - Sumit Kumar Jha
AU  - Kunjabihari Swain
AU  - Murthy Cherukuri
PY  - 2026
DA  - 2026/10/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-70345-4
UR  - https://www.nature.com/articles/s41598-026-70345-4
AB  - The increased adoption of the smart grid (SG) infrastructure to overcome the limitations of traditional grid have faced growing challenges for real-time monitoring and classification of features due to the complexity and dynamic nature of power quality disturbances (PQDs). In particular, when PQDs overlap each other, traditional approaches relying on signal processing techniques tend to lose the dynamic, non-periodic characteristics which define certain PQDs. In this proposed work, a novel dual-stage hybrid architecture based on convolutional neural networks (CNNs) and gated recurrent units (GRUs) augmented by self-attention at both stages for real-time high performance PQD classification is presented. This novel hybrid architecture is allows for spatial and temporal feature extraction from electrical power signals, overcoming the weaknesses encountered in traditional approaches. In contrast to previous models that consider either local or sequential patterns independently, the proposed architecture combines both techniques enabling a more robust and computationally-efficient architecture demonstrates software-level real-time inference (21 ms) and provides a computationally efficient architecture suitable for future embedded deployment. The experimental outcomes on the benchmark databases compared to the state-of-the-art convolutional neural network-long short-term memory (CNN-LSTM) architecture offers improved execution time of 21 ms and a classification accuracy of 98.6%. It also outperforms both traditional CNN architecture with improved latency and high accuracy proposing it as a viable alternative for smart grid use cases like phasor measurement units (PMUs), microcontroller-based devices, etc.
SN  - 2045-2322
ER  -