Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 5 min ago
PreprintCC BY-SA 4.0arXiv

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

Abstract

Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.

Related

  1. Bayesian bilevel operator learning with low-rank adaptation for efficient uncertainty quantification of PDE inverse problems.
    Ray Zirui Zhang, Christopher E Miles, Xiaohui Xie +1
    Nature communicationsPeer-reviewedCC BYFull textStatistical & nonlinear physicsEurope PMC
  2. A Discretely Entropy Conserving/Stable Flux Reconstruction Scheme via Hybridized Split Form Differential Operator and Generalized Entropy Projection
    Geng Liang, Junjie Wang, Hui Xu
    arXivPreprintarXiv licenceFull textNumerical analysis & scientific computingComputational physicsarXiv
  3. LeMON: Learning to learn multi-operator networks
    Jingmin Sun, Zecheng Zhang, Hayden Schaeffer
    NeurocomputingPeer-reviewedLicence not statedFull text21 citedStatistical & nonlinear physicsOpenAlex
  4. Reconstruction of Unobserved Core Electron Density in Tokamak Plasmas with a Neural Operator Transport Surrogate and Uncertainty Quantification
    D. Sorokin, A. Granovskiy, M. Stokolesov +3
    arXivPreprintCC BY-NC-SA 4.0Full textPlasma physicsarXiv
  5. Topos Theory and ZEBTS‑SUPER: A Rigorous Categorical and Operator‑Geometric Reconstruction of Physical Reality
    Anatolii Mukha
    Zenodo (CERN European Organization for Nuclear Research)PreprintCC BY48 citedAtomic, molecular & optical physicsOpenAlex
BibTeX
@misc{hoffmann2026reconstruction,
  title = {{Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation}},
  author = {Jakob Marcel Hoffmann and Yosuke Hasegawa and Alexander Stroh},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.20857},
  eprint = {2609.20857},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.20857},
  note = {CC BY-SA 4.0},
}
RIS
TY  - UNPB
TI  - Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation
AU  - Jakob Marcel Hoffmann
AU  - Yosuke Hasegawa
AU  - Alexander Stroh
PY  - 2026
DA  - 2026/09/01
PB  - arXiv
DO  - 10.48550/arxiv.2609.20857
UR  - https://arxiv.org/abs/2609.20857
AB  - Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.
ER  -