Development and internal validation of a machine learning model for predicting acute chemotherapy-induced nausea and vomiting after intra-arterial interventional therapy in patients with liver cancer
- 1Department of Interventional Oncology, Tianjin Medical University Cancer Hospital and Institute, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin's Clinical Research Center for Cancer, Tianjin, China
- 2Department of Hepatobiliary Cancer, Tianjin Medical University Cancer Hospital and Institute, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin's Clinical Research Center for Cancer, Tianjin, China
- 3Tianjin Medical University Cancer Hospital and Institute, National Clinical Research Center for Cancer, National Clinical Research Center for Interventional Medicine, Key Laboratory of Cancer Prevention and Therapy, Tianjin's Clinical Research Center for Cancer, Tianjin, China
Abstract
Objective: To develop and internally validate an interpretable machine learning model for predicting acute chemotherapy-induced nausea and vomiting (ACINV) after intra-arterial interventional therapy (IAIT) in patients with primary liver cancer.
Methods: This retrospective cohort included 1062 patients who underwent IAIT in China. ACINV was defined as Common Terminology Criteria for Adverse Events (CTCAE) grade ≥ 2 nausea or vomiting within 24 hours. Patients were allocated to a training set (n = 638) and a held-out internal validation set (n = 424). Seven algorithms were compared using nested stratified five-fold cross-validation. Outer folds generated out-of-fold (OOF) predictions, whereas inner folds supported tuning and threshold selection. Imputation, encoding, standardization, and least absolute shrinkage and selection operator (LASSO) selection were fitted only to training observations in each partition. Preprocessing was re-estimated within folds used for LASSO penalty selection. SMOTE was applied only within model-fitting partitions after predictor selection. Algorithms were ranked by pooled OOF area under the curve (AUC), with the Brier score resolving ties. The selected pipeline was refitted on the complete training set and evaluated in internal validation.
Results: ACINV occurred in 380 patients (35.8%). The final refit retained 11 predictors. Random forest achieved the highest pooled OOF AUC (0.941; 95% CI, 0.923–0.958) and a Brier score of 0.092. In internal validation, its AUC was 0.962 (95% CI, 0.946–0.978), Brier score was 0.073, calibration intercept was −0.090, and calibration slope was 1.056. SHAP analysis supported model interpretation, and the locked model was incorporated into a prototype calculator.
Conclusions: The model showed promising internal performance. External validation and prospective impact evaluation are required before clinical implementation.
Trial registration: This study was registered in Chinese Clinical Trial Registry (ChiCTR-2500110585).
Related
- Development and internal validation of a nomogram for predicting bacterial meningitis in preterm infants with late-onset sepsis
- Development and internal validation of machine learning models for predicting lymph node metastasis in cutaneous head and neck melanoma
- Development and internal validation of a nomogram for predicting flexible bronchoscopy utilization in children with lobar pneumonia caused by Mycoplasma pneumoniae: a single-center retrospective cohort study
- Development and internal temporal validation of an explainable XGBoost model for predicting clinical pregnancy after frozen embryo transfer
- Development and internal validation of a nomogram for predicting mechanical ventilation requirement in adult tetanus patients: a dual-center retrospective study
BibTeX
@article{lu2026development,
title = {{Development and internal validation of a machine learning model for predicting acute chemotherapy-induced nausea and vomiting after intra-arterial interventional therapy in patients with liver cancer}},
author = {Yan Lu and Ruishuang Zheng and Haipeng Yu and Xueling Yang and Yanan Liu and Yongjian Wang and Dongjun Liu},
journal = {Asia-Pacific Journal of Oncology Nursing},
year = {2026},
month = oct,
doi = {10.1016/j.apjon.2026.101040},
url = {https://doi.org/10.1016/j.apjon.2026.101040},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Development and internal validation of a machine learning model for predicting acute chemotherapy-induced nausea and vomiting after intra-arterial interventional therapy in patients with liver cancer
AU - Yan Lu
AU - Ruishuang Zheng
AU - Haipeng Yu
AU - Xueling Yang
AU - Yanan Liu
AU - Yongjian Wang
AU - Dongjun Liu
PY - 2026
DA - 2026/10/03
JO - Asia-Pacific Journal of Oncology Nursing
DO - 10.1016/j.apjon.2026.101040
UR - https://doi.org/10.1016/j.apjon.2026.101040
AB - Objective: To develop and internally validate an interpretable machine learning model for predicting acute chemotherapy-induced nausea and vomiting (ACINV) after intra-arterial interventional therapy (IAIT) in patients with primary liver cancer. Methods: This retrospective cohort included 1062 patients who underwent IAIT in China. ACINV was defined as Common Terminology Criteria for Adverse Events (CTCAE) grade ≥ 2 nausea or vomiting within 24 hours. Patients were allocated to a training set (n = 638) and a held-out internal validation set (n = 424). Seven algorithms were compared using nested stratified five-fold cross-validation. Outer folds generated out-of-fold (OOF) predictions, whereas inner folds supported tuning and threshold selection. Imputation, encoding, standardization, and least absolute shrinkage and selection operator (LASSO) selection were fitted only to training observations in each partition. Preprocessing was re-estimated within folds used for LASSO penalty selection. SMOTE was applied only within model-fitting partitions after predictor selection. Algorithms were ranked by pooled OOF area under the curve (AUC), with the Brier score resolving ties. The selected pipeline was refitted on the complete training set and evaluated in internal validation. Results: ACINV occurred in 380 patients (35.8%). The final refit retained 11 predictors. Random forest achieved the highest pooled OOF AUC (0.941; 95% CI, 0.923–0.958) and a Brier score of 0.092. In internal validation, its AUC was 0.962 (95% CI, 0.946–0.978), Brier score was 0.073, calibration intercept was −0.090, and calibration slope was 1.056. SHAP analysis supported model interpretation, and the locked model was incorporated into a prototype calculator. Conclusions: The model showed promising internal performance. External validation and prospective impact evaluation are required before clinical implementation. Trial registration: This study was registered in Chinese Clinical Trial Registry (ChiCTR-2500110585).
SN - 2347-5625
SN - 2349-6673
ER -