Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 43 min ago
PreprintCC BY 4.0arXiv

Measurement-Error-Aware Causal Distributed-Lag Quantile Modeling of Indoor Air Pollution and Short-Term Lung-Function Deterioration

Abstract

Low-cost indoor air-quality sensors could support personalized asthma prevention, but their nonlinear measurement error, delayed exposure effects, time-varying confounding, and heterogeneous lower-tail responses limit risk estimation. We present CAUSALQUANT-ASTHMA, a measurement-error-aware causal quantile distributed-lag framework for short-horizon peak expiratory flow analysis. Sparse reference measurements train a nonlinear calibration model; stabilized sequential generalized-propensity weights address measured exposure assignment; and a susceptibility-modulated, smooth, noncrossing quantile model estimates lag-specific and sustained-exposure contrasts. Because no authorized cohort simultaneously provided dense indoor sensing, reference co-location, and outcome-compatible longitudinal data, evaluation used five semi-synthetic panels with known counterfactual truth, 150 patients and 12,600 patient-days per realization. Across eight methods, CAUSALQUANT achieved a dose-response integrated absolute error of 0.304 plus or minus 0.094, improving 24.2 percent over the strongest measurement-error and propensity-weighted baseline. It also obtained the lowest overall pinball loss, 1.065, while maintaining zero quantile crossings and 78.1 percent coverage for the nominal 80 percent interval. Sensor calibration reduced held-out exposure RMSE by 33.7 percent. Stress tests quantified degradation under sensor noise, missing personal measurements, and hidden confounding. These findings establish methodological feasibility and reproducibility, not clinical effectiveness; prospective, governance-approved external validation is required before patient-level interpretation or deployment.

Related

  1. Clouded Representatives and Score Matching for Distributed Quantile Regression
    Keren Li, Boxiang Wang
    arXivPreprintCC BY 4.0Full textStatisticsarXiv
  2. Distributed Selective Inference for Quantile Regression
    Xiaohui Yuan, Jiahan Teng, Yan Zhou
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  3. Heterogeneity-calibrated Byzantine-robust distributed composite quantile regression
    Xiaofei Wu, Jian Qing Shi
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  4. Usefulness of Quantile-Aware Diffusion Modeling for Highly Imbalanced Tabular Data
    Abu Talha, Peng Liu, Souradyuti Paul
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  5. Modeling and Performance Evaluation of Distributed Satellite Antennas: Space Is Much Closer Than One Might Think
    Giacomo Bacci, Riccardo De Gaudenzi, Marco Luise +1
    arXivPreprintCC BY 4.0Full textGeneral mathematicsarXiv
BibTeX
@misc{alkobaisi2026measurementerroraware,
  title = {{Measurement-Error-Aware Causal Distributed-Lag Quantile Modeling of Indoor Air Pollution and Short-Term Lung-Function Deterioration}},
  author = {Shayma Alkobaisi and Anas Ali},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.31646},
  eprint = {2609.31646},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.31646},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Measurement-Error-Aware Causal Distributed-Lag Quantile Modeling of Indoor Air Pollution and Short-Term Lung-Function Deterioration
AU  - Shayma Alkobaisi
AU  - Anas Ali
PY  - 2026
DA  - 2026/09/12
PB  - arXiv
DO  - 10.48550/arxiv.2609.31646
UR  - https://arxiv.org/abs/2609.31646
AB  - Low-cost indoor air-quality sensors could support personalized asthma prevention, but their nonlinear measurement error, delayed exposure effects, time-varying confounding, and heterogeneous lower-tail responses limit risk estimation. We present CAUSALQUANT-ASTHMA, a measurement-error-aware causal quantile distributed-lag framework for short-horizon peak expiratory flow analysis. Sparse reference measurements train a nonlinear calibration model; stabilized sequential generalized-propensity weights address measured exposure assignment; and a susceptibility-modulated, smooth, noncrossing quantile model estimates lag-specific and sustained-exposure contrasts. Because no authorized cohort simultaneously provided dense indoor sensing, reference co-location, and outcome-compatible longitudinal data, evaluation used five semi-synthetic panels with known counterfactual truth, 150 patients and 12,600 patient-days per realization. Across eight methods, CAUSALQUANT achieved a dose-response integrated absolute error of 0.304 plus or minus 0.094, improving 24.2 percent over the strongest measurement-error and propensity-weighted baseline. It also obtained the lowest overall pinball loss, 1.065, while maintaining zero quantile crossings and 78.1 percent coverage for the nominal 80 percent interval. Sensor calibration reduced held-out exposure RMSE by 33.7 percent. Stress tests quantified degradation under sensor noise, missing personal measurements, and hidden confounding. These findings establish methodological feasibility and reproducibility, not clinical effectiveness; prospective, governance-approved external validation is required before patient-level interpretation or deployment.
ER  -