Comparative longitudinal evaluation of DIMS, progressive addition and single-vision lenses on myopia progression, binocular and visual performance in Spanish children

  1. 1Centro Nazaríes Especialistas, Padul, Granada, Spain.
  2. 2Department of Optics, Laboratory of Vision Sciences and Applications, University of Granada, Granada, Spain.

Abstract

An 18-month prospective, non-randomized comparative observational study evaluated the effects of different optical corrections on myopia progression, binocular vision, and visual performance in Spanish children. Forty-five myopic participants aged 9–14 years were allocated to single-vision lenses (SV), low-addition progressive addition lenses (PALs), or defocus-incorporated multiple segments lenses (DIMS). Assessments included spherical equivalent (SE) and axial length (AL), comprehensive accommodative function evaluated by measuring amplitude of accommodation, positive and negative relative accommodation, accommodative facility, and accommodative response, and binocular function evaluated by measuring phorias, fusional vergences, and stereopsis. In addition, contrast sensitivity (CS), visual disturbance index (VDI), and subjective visual quality were assessed at baseline and at 6, 12, and 18 months. After 18 months, SE progression was −0.59 D for SV, −0.51 D for PALs, and −0.30 D for DIMS, corresponding to a 49% reduction with DIMS compared to SV. AL increased by 0.24, 0.27, and 0.23 millimeters, respectively, although inter-group differences were not significant for AL. Accommodative and binocular functions, visual acuity, CS, and VDI remained stable, while distance stereopsis improved in the DIMS group. These findings suggest an association between DIMS lens wear and reduced myopia progression compared with SV lenses in this cohort, without clinically relevant differences in accommodative or binocular function, visual acuity, or subjective visual quality.

Related

  1. Comparative Physiological and Biochemical Responses of Lettuce (Lactuca sativa L. var. romana) to Foliar Methyl Jasmonate, Nano-Kaolin, and Melatonin Under a Progressive High-Temperature Regime
    Plants (Basel, Switzerland)Peer-reviewedCC BYFull textPlant biologyEurope PMC
  2. Case report: Progressive organ-threatening IgG4-related disease despite conventional immunosuppression: lessons from a 5-year longitudinal follow-up
    Xinyue Zhang, Xiaoyue Deng, Jiaxuan Li +3
    Frontiers in ImmunologyPeer-reviewedCC BY 4.0Full textImmunologyCrossref
  3. Assessing the comparative longitudinal immunogenicity of two commercial foot-and-mouth disease vaccines in crossbred dairy calves in Sebeta Hawas, Ethiopia
    Daniel Gizaw, Ayenalem Fentie, Takele Worku +7
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textPlant biologyCrossref
  4. Longitudinal Economic Burden for Non–Muscle-Invasive Bladder Cancer by EAU Progression Risk Groups Using the Prospective Multicenter COBLAnCE Cohort Linked to the French National Healthcare System Database
    Aldéric M Fraslin, Simone Benhamou, Thierry Lebret +20
    European Urology Open SciencePeer-reviewedCC BY-NC-ND 4.0Full textGeneral biologyStatisticsHAL
  5. Comparative Performance of Biosorption Pretreatments for Vinasse Phytoremediation Using Salvinia minima
    Noelia Romina Tabernero, Silvana Chocobar-Ponce, María de Lourdes Gultemirian +4
    Plants (Basel, Switzerland)Peer-reviewedCC BYFull textPlant biologyEurope PMC
BibTeX
@article{solanomolina2026comparative,
  title = {{Comparative longitudinal evaluation of DIMS, progressive addition and single-vision lenses on myopia progression, binocular and visual performance in Spanish children}},
  author = {Salvador Solano-Molina and Miriam Carrillo-Pulido and Sonia Ortiz-Peregrina and Francesco Martino and Rosario G Anera and José R Jiménez},
  journal = {PLOS One},
  year = {2026},
  month = oct,
  doi = {10.1371/journal.pone.0361471},
  url = {https://doi.org/10.1371/journal.pone.0361471},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Comparative longitudinal evaluation of DIMS, progressive addition and single-vision lenses on myopia progression, binocular and visual performance in Spanish children
AU  - Salvador Solano-Molina
AU  - Miriam Carrillo-Pulido
AU  - Sonia Ortiz-Peregrina
AU  - Francesco Martino
AU  - Rosario G Anera
AU  - José R Jiménez
PY  - 2026
DA  - 2026/10/26
JO  - PLOS One
DO  - 10.1371/journal.pone.0361471
UR  - https://doi.org/10.1371/journal.pone.0361471
AB  - An 18-month prospective, non-randomized comparative observational study evaluated the effects of different optical corrections on myopia progression, binocular vision, and visual performance in Spanish children. Forty-five myopic participants aged 9–14 years were allocated to single-vision lenses (SV), low-addition progressive addition lenses (PALs), or defocus-incorporated multiple segments lenses (DIMS). Assessments included spherical equivalent (SE) and axial length (AL), comprehensive accommodative function evaluated by measuring amplitude of accommodation, positive and negative relative accommodation, accommodative facility, and accommodative response, and binocular function evaluated by measuring phorias, fusional vergences, and stereopsis. In addition, contrast sensitivity (CS), visual disturbance index (VDI), and subjective visual quality were assessed at baseline and at 6, 12, and 18 months. After 18 months, SE progression was −0.59 D for SV, −0.51 D for PALs, and −0.30 D for DIMS, corresponding to a 49% reduction with DIMS compared to SV. AL increased by 0.24, 0.27, and 0.23 millimeters, respectively, although inter-group differences were not significant for AL. Accommodative and binocular functions, visual acuity, CS, and VDI remained stable, while distance stereopsis improved in the DIMS group. These findings suggest an association between DIMS lens wear and reduced myopia progression compared with SV lenses in this cohort, without clinically relevant differences in accommodative or binocular function, visual acuity, or subjective visual quality.
SN  - 1932-6203