Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 19 min ago
PreprintarXiv licencearXiv

Measurement-angle control of a continuously monitored quantum oscillator: purification limits and optimal protocols

Abstract

We study the dynamic purification of a continuously monitored quantum harmonic oscillator coupled to a thermal bath, where the control is the quadrature measurement angle of up to two detectors with prescribed strengths and efficiencies. Within the Gaussian regime, the conditional state covariance obeys a deterministic Riccati equation, and we ask what purity can be reached and sustained by manipulating the angle in time, in analogy with rapid-purification protocols for qubits. We propose, analyze, and compare constant-rate, greedy, vibrational, and variational monitoring strategies on the basis of sustained purity starting from the thermal bath state, and quantify to what extent they are able to maintain higher purity levels compared to lab-fixed or phase-locked detectors. We highlight structural features, operational limits, and optimal protocols from each strategy and study how model parameters shape control performance. We observe that in the absence of measurement-frame anisotropy, the time-dependent strategies achieve higher but similar performance. Once this symmetry is broken, their performances diverge, either improving or worsening depending on the relative timescales of oscillator dynamics, thermalization, and measurement.

Related

  1. A Latent Oscillator Measurement Model to Simulate Emotional-Expression Score Dynamics in Video
    Aleksandar Tomašević, Hudson Golino, Alexander P. Christensen
    arXivPreprintCC BY 4.0Full textStatisticsStatistical & nonlinear physicsarXiv
  2. A Latent Oscillator Measurement Model to Simulate Emotional-Expression Score Dynamics in Video
    Aleksandar Tomašević, Hudson Golino, Alexander P. Christensen
    PsyArXivPreprintCC BY 4.0Full textStatisticsOSF
  3. The divergence of continuously differentiable vector fields
    Thierry De Pauw
    arXivPreprintCC BY-NC-ND 4.0Full textAnalysis & PDEsarXiv
  4. Parameter Estimation for Diffusive Stochastic Master Equations in Continuously Observed Quantum Systems
    Mitsuki Kobayashi, Shohei Nakajima
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  5. Parameter-dependent inhomogeneous boundary-value problems in spaces of continuously differentiable functions
    O. M. Atlasiuk, V. A. Mikhailets
    arXivPreprintarXiv licenceFull textAnalysis & PDEsarXiv
BibTeX
@misc{sabbagh2026measurementangle,
  title = {{Measurement-angle control of a continuously monitored quantum oscillator: purification limits and optimal protocols}},
  author = {Ralph Sabbagh and Olga Movilla Miangolarra and Andrew N. Jordan and Tryphon T. Georgiou},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.00410},
  eprint = {2611.00410},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.00410},
}
RIS
TY  - UNPB
TI  - Measurement-angle control of a continuously monitored quantum oscillator: purification limits and optimal protocols
AU  - Ralph Sabbagh
AU  - Olga Movilla Miangolarra
AU  - Andrew N. Jordan
AU  - Tryphon T. Georgiou
PY  - 2026
DA  - 2026/11/01
PB  - arXiv
DO  - 10.48550/arxiv.2611.00410
UR  - https://arxiv.org/abs/2611.00410
AB  - We study the dynamic purification of a continuously monitored quantum harmonic oscillator coupled to a thermal bath, where the control is the quadrature measurement angle of up to two detectors with prescribed strengths and efficiencies. Within the Gaussian regime, the conditional state covariance obeys a deterministic Riccati equation, and we ask what purity can be reached and sustained by manipulating the angle in time, in analogy with rapid-purification protocols for qubits. We propose, analyze, and compare constant-rate, greedy, vibrational, and variational monitoring strategies on the basis of sustained purity starting from the thermal bath state, and quantify to what extent they are able to maintain higher purity levels compared to lab-fixed or phase-locked detectors. We highlight structural features, operational limits, and optimal protocols from each strategy and study how model parameters shape control performance. We observe that in the absence of measurement-frame anisotropy, the time-dependent strategies achieve higher but similar performance. Once this symmetry is broken, their performances diverge, either improving or worsening depending on the relative timescales of oscillator dynamics, thermalization, and measurement.
ER  -