A retrospective analysis of initial ventilator settings and lung mechanics in COVID-19 patients requiring mechanical ventilation
- 1Texas Health Resources , , ,
- 2Texas Christian University Burnett School of Medicine , , ,
- 3Duke University School of Medicine , , ,
Abstract
Background
During the COVID-19 pandemic, variability in lung mechanics challenged the conventional management of COVID-19-related hypoxemic respiratory failure, particularly on initial presentation. This study evaluated the association between patient characteristics, respiratory system mechanics, and ventilator settings in the first 24 hours of mechanical ventilation with mortality in a large cohort of patients with COVID-19-related hypoxemic respiratory failure.Methods
A multicenter, retrospective analysis of 1,563 mechanically ventilated patients with COVID-19 admitted to the ICU across sixteen hospitals in Texas between 2020 and 2023. Patient characteristics, respiratory system mechanics, and ventilator settings in the first 24 hours after intubation and mechanical ventilation were collected. All-cause in-hospital mortality was reported. Multivariable regression models were used to assess associations with mortality, with sequential addition of patient characteristics, severity of disease, and ventilator parameters.Results
Overall mortality in the study population was 54.4% with higher mortality was observed in patients with increasingly abnormal respiratory system mechanics and gas exchange. We also observed higher mortality associated with PP >30 cmH2O (64.5% vs 50.0%, p<0.001) and DP >14 cmH2O (56.8% vs 49.5%, p<0.007) and lower mortality associated with TV >8 cc/kg PBW compared to TV ≤8 cc/kg PBW (43.4% vs 59.4%, p<0.001) after multivariate regression analysis of covariates.Conclusion
Our retrospective observational, exploratory study illustrated associations between abnormal respiratory mechanics and gas exchange with mortality reported by many others in COVID-19 respiratory failure. The observation of lower mortality in patients receiving TVs >8 cc/kg PBW likely reflected severity of underlying disease and initial clinician judgment, thereby prioritizing minute ventilation needs in patients perceived to be at lower risk for ventilator-induced lung injury. Our study's findings are limited to observations alone and should be cautiously interpreted, acknowledging the need for prospective, randomized control trials to further investigate whether or not there is an impact in mortality with TV >8 cc/kg PBW in otherwise safe mechanical ventilation.
Related
- Semi‐recumbent position for the prevention of ventilator‐associated pneumonia in adults requiring mechanical ventilation
- Perioperative factors related to postoperative mechanical ventilation duration after thoracic surgery requiring one-lung ventilation: a retrospective cohort study
- The association of ICU admission time with mortality in patients with severe pneumonia requiring invasive mechanical ventilation: a retrospective, single-center, multicampus cohort study
- Global Protective Ventilator Settings Are Not Regional Protection: A Compartment-Resolved Framework for Personalizing Mechanical Ventilation in Acute Respiratory Distress Syndrome
- Daily sedation interruption versus no daily sedation interruption for critically ill adults and children requiring invasive mechanical ventilation
BibTeX
@article{vo2026retrospective,
title = {{A retrospective analysis of initial ventilator settings and lung mechanics in COVID-19 patients requiring mechanical ventilation}},
author = {Russell Vo and Uday Rallabhandi and Clark Walker and Ann Davis and Neil MacIntyre and John W. Hollingsworth},
journal = {Journal of critical care medicine (Universitatea de Medicina si Farmacie din Targu-Mures)},
year = {2026},
month = oct,
doi = {10.62838/jccm-2026-0055},
url = {https://europepmc.org/article/PMC/PMC13752166},
note = {CC BY},
}
RIS
TY - JOUR
TI - A retrospective analysis of initial ventilator settings and lung mechanics in COVID-19 patients requiring mechanical ventilation
AU - Russell Vo
AU - Uday Rallabhandi
AU - Clark Walker
AU - Ann Davis
AU - Neil MacIntyre
AU - John W. Hollingsworth
PY - 2026
DA - 2026/10/30
JO - Journal of critical care medicine (Universitatea de Medicina si Farmacie din Targu-Mures)
DO - 10.62838/jccm-2026-0055
UR - https://europepmc.org/article/PMC/PMC13752166
AB - Background During the COVID-19 pandemic, variability in lung mechanics challenged the conventional management of COVID-19-related hypoxemic respiratory failure, particularly on initial presentation. This study evaluated the association between patient characteristics, respiratory system mechanics, and ventilator settings in the first 24 hours of mechanical ventilation with mortality in a large cohort of patients with COVID-19-related hypoxemic respiratory failure.Methods A multicenter, retrospective analysis of 1,563 mechanically ventilated patients with COVID-19 admitted to the ICU across sixteen hospitals in Texas between 2020 and 2023. Patient characteristics, respiratory system mechanics, and ventilator settings in the first 24 hours after intubation and mechanical ventilation were collected. All-cause in-hospital mortality was reported. Multivariable regression models were used to assess associations with mortality, with sequential addition of patient characteristics, severity of disease, and ventilator parameters.Results Overall mortality in the study population was 54.4% with higher mortality was observed in patients with increasingly abnormal respiratory system mechanics and gas exchange. We also observed higher mortality associated with PP >30 cmH2O (64.5% vs 50.0%, p<0.001) and DP >14 cmH2O (56.8% vs 49.5%, p<0.007) and lower mortality associated with TV >8 cc/kg PBW compared to TV ≤8 cc/kg PBW (43.4% vs 59.4%, p<0.001) after multivariate regression analysis of covariates.Conclusion Our retrospective observational, exploratory study illustrated associations between abnormal respiratory mechanics and gas exchange with mortality reported by many others in COVID-19 respiratory failure. The observation of lower mortality in patients receiving TVs >8 cc/kg PBW likely reflected severity of underlying disease and initial clinician judgment, thereby prioritizing minute ventilation needs in patients perceived to be at lower risk for ventilator-induced lung injury. Our study's findings are limited to observations alone and should be cautiously interpreted, acknowledging the need for prospective, randomized control trials to further investigate whether or not there is an impact in mortality with TV >8 cc/kg PBW in otherwise safe mechanical ventilation.
SN - 2393-1809
SN - 2393-1817
ER -