Skip to content
DraconiticResearch
Search Sources API
206,698 studies31 sourcesUpdated 6 min ago
Peer-reviewedCC BY-NC-ND 4.0Translational Breast Cancer Research

Zero echo time versus T1-weighted gradient-recalled echo MRI of breast biopsy markers: a phantom study comparing susceptibility artifact volume and geometric dimensions

5 affiliations
  1. 1Division of Radiology Research, Department of Radiology, Mayo Clinic, Rochester, MN, USA
  2. 2Division of Breast Imaging and Intervention, Department of Radiology, Mayo Clinic, Rochester, MN, USA
  3. 3Division of Medical Physics, Department of Radiology, Mayo Clinic, Rochester, MN, USA
  4. 4Division of Breast and Melanoma Surgical Oncology, Department of Surgery, Mayo Clinic, Rochester, MN, USA
  5. 5Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA

Abstract

Background: Breast biopsy markers or clips play a critical role in marking biopsy sites, cross-correlating on multi-modality imaging, guiding surgical planning, and monitoring treatment response. However, susceptibility artifacts from metallic breast biopsy markers on conventional T1-weighted (T1w) magnetic resonance imaging (MRI) can obscure adjacent tissues, precluding accurate signaling and enhancement of any residual disease, particularly following neoadjuvant chemotherapy and during targeted axillary dissection procedures. Zero echo time (ZTE) MRI, by acquiring signal before substantial phase dispersion occurs, has the potential to reduce these artifacts. The objective of this study is to compare susceptibility artifact volume and geometric dimensions of breast biopsy markers quantitatively between ZTE and T1w gradient-recalled echo (GRE) MRI acquisitions in a controlled phantom setting.

Methods: Thirty-eight breast biopsy markers (37 commercially available, 1 research marker; 33 metallic, 5 non-metallic) were embedded in water-based gelatin phantoms and imaged at 1.5T using a T1w GRE sequence (Vibrant FLEX) and a ZTE sequence (oZTEo). For each sequence, susceptibility artifact volume and maximum length of the marker were quantified using adaptive thresholding with morphological refinement and compared with physical marker dimensions derived from mass and material density. Statistical analysis included Spearman correlation and Wilcoxon signed-rank tests considering P<0.05 as denoting statistical significance.

Results: Compared with the physical marker volume, T1w GRE imaging produced a volumetric overestimation of 307±286 mm³ (mean ± SD), whereas ZTE imaging showed a smaller overestimation of 72±65 mm³ (P<0.001). T1w GRE imaging marker volumes were ~4–5 times larger than those from ZTE, and their corresponding marker lengths were approximately ~1.4–1.5 times greater. Image marker volumes and maximum lengths were larger than their true measurements on both MRI acquisitions. Correlation with true physical volume was weak for both T1w (ρ=0.21, P=0.22) and ZTE (ρ=0.32, P=0.053). Length correlation with physical measurement was stronger for ZTE (ρ=0.59, P<0.001) than T1w (ρ=0.28, P=0.001).

Conclusions: In a controlled phantom setting, ZTE MRI demonstrated reduced susceptibility artifact volume and improved geometric agreement with true marker dimensions compared to T1w GRE. These findings warrant further investigation through prospective in vivo validation before clinical recommendations can be made.

Related

  1. In vitro susceptibility of Cutibacterium acnes to dalbavancin: comparison between gradient test and the agar dilution reference method.
    Sara Svensson, Susanne Jacobsson, Erika Matuschek +1
    The Journal of antimicrobial chemotherapyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Comparing Short-Term Clinical Outcomes and Survivorship of Complex Revision Total Hip Arthroplasty: Custom Triflange Acetabular Implants Vs Standard Cage Reconstruction
    Arthroplasty todayPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  3. Comparing Outcomes after Core Muscle Repair by Repair Technique: A Systematic Review
    Journal of the American Academy of Orthopaedic Surgeons. Global research & reviewsPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  4. A double-blind randomized controlled trial comparing intranasal dexmedetomidine with and without fentanyl for pediatric premedication
    Saowaphak Lapmahapaisan, Piyawan Koopredechat, Issada Jindawatthana +1
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaCrossref
  5. Extracting smoking history from clinical notes for lung cancer screening decision support: comparing a structured-judgment model with general-purpose large language models
    A. Wright, S. Liu, A. P. Wright
    medRxivPreprintAll rights reservedFull textEpidemiology & public healthmedRxiv
BibTeX
@article{masud2026zero,
  title = {{Zero echo time versus T1-weighted gradient-recalled echo MRI of breast biopsy markers: a phantom study comparing susceptibility artifact volume and geometric dimensions}},
  author = {Abdullah Al Masud and Stephane R. Chartier and Chidi T. Nwachukwu and Ian D. Langenfeld and Joshua D. Trzasko and Jeffrey E. Johnson and Gina K. Hesley and Matthew W. Urban and Christine U. Lee},
  journal = {Translational Breast Cancer Research},
  year = {2026},
  month = jul,
  doi = {10.21037/tbcr-2026-0035},
  url = {https://doi.org/10.21037/tbcr-2026-0035},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Zero echo time versus T1-weighted gradient-recalled echo MRI of breast biopsy markers: a phantom study comparing susceptibility artifact volume and geometric dimensions
AU  - Abdullah Al Masud
AU  - Stephane R. Chartier
AU  - Chidi T. Nwachukwu
AU  - Ian D. Langenfeld
AU  - Joshua D. Trzasko
AU  - Jeffrey E. Johnson
AU  - Gina K. Hesley
AU  - Matthew W. Urban
AU  - Christine U. Lee
PY  - 2026
DA  - 2026/07/16
JO  - Translational Breast Cancer Research
DO  - 10.21037/tbcr-2026-0035
UR  - https://doi.org/10.21037/tbcr-2026-0035
AB  - Background: Breast biopsy markers or clips play a critical role in marking biopsy sites, cross-correlating on multi-modality imaging, guiding surgical planning, and monitoring treatment response. However, susceptibility artifacts from metallic breast biopsy markers on conventional T1-weighted (T1w) magnetic resonance imaging (MRI) can obscure adjacent tissues, precluding accurate signaling and enhancement of any residual disease, particularly following neoadjuvant chemotherapy and during targeted axillary dissection procedures. Zero echo time (ZTE) MRI, by acquiring signal before substantial phase dispersion occurs, has the potential to reduce these artifacts. The objective of this study is to compare susceptibility artifact volume and geometric dimensions of breast biopsy markers quantitatively between ZTE and T1w gradient-recalled echo (GRE) MRI acquisitions in a controlled phantom setting.  Methods: Thirty-eight breast biopsy markers (37 commercially available, 1 research marker; 33 metallic, 5 non-metallic) were embedded in water-based gelatin phantoms and imaged at 1.5T using a T1w GRE sequence (Vibrant FLEX) and a ZTE sequence (oZTEo). For each sequence, susceptibility artifact volume and maximum length of the marker were quantified using adaptive thresholding with morphological refinement and compared with physical marker dimensions derived from mass and material density. Statistical analysis included Spearman correlation and Wilcoxon signed-rank tests considering P<0.05 as denoting statistical significance.  Results: Compared with the physical marker volume, T1w GRE imaging produced a volumetric overestimation of 307±286 mm³ (mean ± SD), whereas ZTE imaging showed a smaller overestimation of 72±65 mm³ (P<0.001). T1w GRE imaging marker volumes were ~4–5 times larger than those from ZTE, and their corresponding marker lengths were approximately ~1.4–1.5 times greater. Image marker volumes and maximum lengths were larger than their true measurements on both MRI acquisitions. Correlation with true physical volume was weak for both T1w (ρ=0.21, P=0.22) and ZTE (ρ=0.32, P=0.053). Length correlation with physical measurement was stronger for ZTE (ρ=0.59, P<0.001) than T1w (ρ=0.28, P=0.001).  Conclusions: In a controlled phantom setting, ZTE MRI demonstrated reduced susceptibility artifact volume and improved geometric agreement with true marker dimensions compared to T1w GRE. These findings warrant further investigation through prospective in vivo validation before clinical recommendations can be made.
SN  - 2218-6778
ER  -