Limitations of clDice for Evaluating Pancreatic Duct Segmentation in CT.
- 1Department of Engineering Sciences, Jade Hochschule Wilhelmshaven, 26389 Wilhelmshaven, Germany.
Abstract
Background/Objectives: Centerline Dice (clDice) emphasizes skeleton overlap, but a high score does not establish connectivity. This empirical study, which proposes no new metric, measured how often high-scoring pancreatic-duct segmentations on computed tomography (CT) differ from their references in connected-component count, and what changes that frequency. Methods: Dice, clDice and component counts were compared for 235 held-out PANORAMA CT predictions of a public model. The references were algorithm-generated, so a difference shows disagreement, not anatomical correctness. Thresholds, small-component cleanup and skeleton-based counting were varied. Further tests used a second model, known cuts, synthetic tubes and retinal labels. Synthetic-tube radii illustrate the mechanism, not clinical thresholds. Results: Among 81 predictions with both scores above 0.85, 51 (63.0%; 95% CI 52-73%) differed in component count; a second model gave 32 of 55 (58.2%). Among 86 predictions with Dice above 0.85, cleanup alone moved discordant cases between 25 and 60, and skeleton-based counting reclassified seven cases. After one known cut, 194 of 199 references kept both scores above 0.85 despite the break. Conclusions: High clDice does not ensure matching connectivity. Studies should report a direct connectivity measure alongside clDice and state their cleanup and skeletonization conventions, because these conventions alone changed the reported frequency.
Related
- Preoperative CT Suspicion of Main Pancreatic Duct Injury in Isolated Blunt Pancreatic Trauma: A Case Report With Operative Correlation
- Endoscopic management of pancreatic duct stones and stricture in chronic pancreatitis using a fully covered self-expandable metal stent.
- Antegrade Electrohydraulic Lithotripsy of an Obstructing Pancreatic Duct Stone Through EUS-Guided Pancreatogastrostomy
- Successful conservative management of a delayed duodenal perforation following displacement and removal of a pancreatic duct stent
- Steroid-resistant Relapse of Autoimmune Pancreatitis with Marked Main Pancreatic Duct Dilatation Mimicking Multifocal Pancreatic Cancer
BibTeX
@article{adhikary2026limitations,
title = {{Limitations of clDice for Evaluating Pancreatic Duct Segmentation in CT.}},
author = {Souraj Adhikary and Negar Chabi and Andre Mastmeyer},
journal = {Tomography (Ann Arbor, Mich.)},
year = {2026},
month = oct,
doi = {10.3390/tomography12110155},
url = {https://europepmc.org/article/MED/43083645},
note = {CC BY},
}
RIS
TY - JOUR
TI - Limitations of clDice for Evaluating Pancreatic Duct Segmentation in CT.
AU - Souraj Adhikary
AU - Negar Chabi
AU - Andre Mastmeyer
PY - 2026
DA - 2026/10/27
JO - Tomography (Ann Arbor, Mich.)
DO - 10.3390/tomography12110155
UR - https://europepmc.org/article/MED/43083645
AB - Background/Objectives: Centerline Dice (clDice) emphasizes skeleton overlap, but a high score does not establish connectivity. This empirical study, which proposes no new metric, measured how often high-scoring pancreatic-duct segmentations on computed tomography (CT) differ from their references in connected-component count, and what changes that frequency. Methods: Dice, clDice and component counts were compared for 235 held-out PANORAMA CT predictions of a public model. The references were algorithm-generated, so a difference shows disagreement, not anatomical correctness. Thresholds, small-component cleanup and skeleton-based counting were varied. Further tests used a second model, known cuts, synthetic tubes and retinal labels. Synthetic-tube radii illustrate the mechanism, not clinical thresholds. Results: Among 81 predictions with both scores above 0.85, 51 (63.0%; 95% CI 52-73%) differed in component count; a second model gave 32 of 55 (58.2%). Among 86 predictions with Dice above 0.85, cleanup alone moved discordant cases between 25 and 60, and skeleton-based counting reclassified seven cases. After one known cut, 194 of 199 references kept both scores above 0.85 despite the break. Conclusions: High clDice does not ensure matching connectivity. Studies should report a direct connectivity measure alongside clDice and state their cleanup and skeletonization conventions, because these conventions alone changed the reported frequency.
SN - 2379-1381
SN - 2379-139X
ER -