Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BYTomography (Ann Arbor, Mich.)

Limitations of clDice for Evaluating Pancreatic Duct Segmentation in CT.

  1. 1Department of Engineering Sciences, Jade Hochschule Wilhelmshaven, 26389 Wilhelmshaven, Germany.

Abstract

Background/Objectives: Centerline Dice (clDice) emphasizes skeleton overlap, but a high score does not establish connectivity. This empirical study, which proposes no new metric, measured how often high-scoring pancreatic-duct segmentations on computed tomography (CT) differ from their references in connected-component count, and what changes that frequency. Methods: Dice, clDice and component counts were compared for 235 held-out PANORAMA CT predictions of a public model. The references were algorithm-generated, so a difference shows disagreement, not anatomical correctness. Thresholds, small-component cleanup and skeleton-based counting were varied. Further tests used a second model, known cuts, synthetic tubes and retinal labels. Synthetic-tube radii illustrate the mechanism, not clinical thresholds. Results: Among 81 predictions with both scores above 0.85, 51 (63.0%; 95% CI 52-73%) differed in component count; a second model gave 32 of 55 (58.2%). Among 86 predictions with Dice above 0.85, cleanup alone moved discordant cases between 25 and 60, and skeleton-based counting reclassified seven cases. After one known cut, 194 of 199 references kept both scores above 0.85 despite the break. Conclusions: High clDice does not ensure matching connectivity. Studies should report a direct connectivity measure alongside clDice and state their cleanup and skeletonization conventions, because these conventions alone changed the reported frequency.

Related

  1. Preoperative CT Suspicion of Main Pancreatic Duct Injury in Isolated Blunt Pancreatic Trauma: A Case Report With Operative Correlation
    Syeda Sarah Kazmi, Syeda Zubaria Qamar, Ahmed Ali +5
    Clinical case reportsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Endoscopic management of pancreatic duct stones and stricture in chronic pancreatitis using a fully covered self-expandable metal stent.
    Nan Zeng, Beibei Li, Jingbo Yang
    EndoscopyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. Antegrade Electrohydraulic Lithotripsy of an Obstructing Pancreatic Duct Stone Through EUS-Guided Pancreatogastrostomy
    Ridhima Kaul, Astha Saini-Goeman, Arjun Chatterjee +2
    ACG Case Reports JournalPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  4. Successful conservative management of a delayed duodenal perforation following displacement and removal of a pancreatic duct stent
    Shaofei Wang, Weiping Zhang, Liping Zhang +4
    EndoscopyPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  5. Steroid-resistant Relapse of Autoimmune Pancreatitis with Marked Main Pancreatic Duct Dilatation Mimicking Multifocal Pancreatic Cancer
    Kenji Hirano, Kanami Kondo, Toshifumi Saito +7
    Internal MedicinePeer-reviewedCC BY-NC-NDFull text1 citedGeneral medicineJ-STAGE
BibTeX
@article{adhikary2026limitations,
  title = {{Limitations of clDice for Evaluating Pancreatic Duct Segmentation in CT.}},
  author = {Souraj Adhikary and Negar Chabi and Andre Mastmeyer},
  journal = {Tomography (Ann Arbor, Mich.)},
  year = {2026},
  month = oct,
  doi = {10.3390/tomography12110155},
  url = {https://europepmc.org/article/MED/43083645},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Limitations of clDice for Evaluating Pancreatic Duct Segmentation in CT.
AU  - Souraj Adhikary
AU  - Negar Chabi
AU  - Andre Mastmeyer
PY  - 2026
DA  - 2026/10/27
JO  - Tomography (Ann Arbor, Mich.)
DO  - 10.3390/tomography12110155
UR  - https://europepmc.org/article/MED/43083645
AB  - Background/Objectives: Centerline Dice (clDice) emphasizes skeleton overlap, but a high score does not establish connectivity. This empirical study, which proposes no new metric, measured how often high-scoring pancreatic-duct segmentations on computed tomography (CT) differ from their references in connected-component count, and what changes that frequency. Methods: Dice, clDice and component counts were compared for 235 held-out PANORAMA CT predictions of a public model. The references were algorithm-generated, so a difference shows disagreement, not anatomical correctness. Thresholds, small-component cleanup and skeleton-based counting were varied. Further tests used a second model, known cuts, synthetic tubes and retinal labels. Synthetic-tube radii illustrate the mechanism, not clinical thresholds. Results: Among 81 predictions with both scores above 0.85, 51 (63.0%; 95% CI 52-73%) differed in component count; a second model gave 32 of 55 (58.2%). Among 86 predictions with Dice above 0.85, cleanup alone moved discordant cases between 25 and 60, and skeleton-based counting reclassified seven cases. After one known cut, 194 of 199 references kept both scores above 0.85 despite the break. Conclusions: High clDice does not ensure matching connectivity. Studies should report a direct connectivity measure alongside clDice and state their cleanup and skeletonization conventions, because these conventions alone changed the reported frequency.
SN  - 2379-1381
SN  - 2379-139X
ER  -