Skip to content
DraconiticResearch
Search Sources API
182,469 studies31 sourcesUpdated 32 min ago
PreprintCC BY-NC-SA 4.0arXiv

Attenuation corrected activity reconstruction for listmode TOF-PET data

Abstract

Time-of-flight (TOF) positron emission tomography (PET) emission data allow joint estimation of the activity and attenuation images. The methods proposed so far rely on reconstructions from TOF histograms of the measurements. However, with the rapid data increase of total-body (TB) scanners and the ever improving TOF and intrinsic resolutions, more memory and computation efficient techniques for joint reconstruction need to be developed. In this work, a modified version of the maximum likelihood activity and attenuation correction factors algorithm (MLACF) is presented, that jointly estimates the activity image together with the attenuation factors (AFs) from listmode emission data. The method does not require TOF histogramming of the data, however it still relies on a coarsely sampled (i.e. mashed) non-TOF histogram of the emission data. The activity distribution is subsequently quantified by reconstructing and enforcing known expected tissue attenuation on an attenuation reconstruction from the estimated AF values. The algorithm is evaluated using 3D simulations as well as clinical TOF-PET measurements of a patient scan and compared to reference reconstructions. As could be expected, we find the reconstruction accuracies improve with an "optimal" histogramming of the TOF emission data, increasing the signal to noise ratio of the data used for joint estimation. With an "optimal" histogramming of the measurements, the attenuation corrected activity distributions from TOF emission data only are comparable to the gold-standard in PET/CT.

Related

  1. Maximum-Likelihood Joint Image Reconstruction/Motion Estimation in Attenuation-Corrected Respiratory Gated PET/CT Using a Single Attenuation Map
    Alexandre Bousse, Ottavia Bertolli, David Atkinson +4
    IEEE Transactions on Medical ImagingPeer-reviewedCC BY50 citedBiological & medical physicsHAL
  2. Stray-light-limited attenuation in integrated quantum key distribution transmitters
    Julian Konig, Andrea Peri, Job Perey +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  3. Encrypted cloning of qubits is able to serve as a quantum primitive, already on non-error-corrected quantum hardware
    Koji Yamaguchi, Leon Rullkötter, Ibrahim Shehzad +3
    Physical Review ResearchPeer-reviewedPublisher termsAtomic, molecular & optical physicsCrossref
  4. Fault-tolerant execution of error-corrected quantum algorithms
    Michael A. Perlin, Zichang He, Anthony Alexiades Armenakas +9
    Physical Review XPeer-reviewedCC BY 4.0Atomic, molecular & optical physicsCrossref
  5. Dark matter attenuation inside the Earth: a Boltzmann equation approach
    Chuan-Yang Xing, Chen Xia
    Journal of High Energy PhysicsPeer-reviewedCC BY 4.0Full textHigh-energy & particle physicsCrossref
BibTeX
@misc{rezaei2026attenuation,
  title = {{Attenuation corrected activity reconstruction for listmode TOF-PET data}},
  author = {Ahmadreza Rezaei and Suleman Surti and Samuel Matej and Joel S. Karp and Johan Nuyts},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.23655},
  eprint = {2610.23655},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.23655},
  note = {CC BY-NC-SA 4.0},
}
RIS
TY  - UNPB
TI  - Attenuation corrected activity reconstruction for listmode TOF-PET data
AU  - Ahmadreza Rezaei
AU  - Suleman Surti
AU  - Samuel Matej
AU  - Joel S. Karp
AU  - Johan Nuyts
PY  - 2026
DA  - 2026/10/16
PB  - arXiv
DO  - 10.48550/arxiv.2610.23655
UR  - https://arxiv.org/abs/2610.23655
AB  - Time-of-flight (TOF) positron emission tomography (PET) emission data allow joint estimation of the activity and attenuation images. The methods proposed so far rely on reconstructions from TOF histograms of the measurements. However, with the rapid data increase of total-body (TB) scanners and the ever improving TOF and intrinsic resolutions, more memory and computation efficient techniques for joint reconstruction need to be developed. In this work, a modified version of the maximum likelihood activity and attenuation correction factors algorithm (MLACF) is presented, that jointly estimates the activity image together with the attenuation factors (AFs) from listmode emission data. The method does not require TOF histogramming of the data, however it still relies on a coarsely sampled (i.e. mashed) non-TOF histogram of the emission data. The activity distribution is subsequently quantified by reconstructing and enforcing known expected tissue attenuation on an attenuation reconstruction from the estimated AF values. The algorithm is evaluated using 3D simulations as well as clinical TOF-PET measurements of a patient scan and compared to reference reconstructions. As could be expected, we find the reconstruction accuracies improve with an "optimal" histogramming of the TOF emission data, increasing the signal to noise ratio of the data used for joint estimation. With an "optimal" histogramming of the measurements, the attenuation corrected activity distributions from TOF emission data only are comparable to the gold-standard in PET/CT.
ER  -