Development of a Rapid Automated Point-of-Care Test for Mycobacterium tuberculosis Detection From Tongue Swabs and Sputum Specimens on the DASH® Rapid PCR System.
5 affiliations
- 1Center for Innovation in Global Health Technologies, Robert J. Havey Institute for Global Health, Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA.
- 2Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA.
- 3Department of Environmental and Occupational Health Sciences, University of Washington, Seattle, Washington, USA.
- 4South African Tuberculosis Vaccine Initiative, Institute of Infectious Disease & Molecular Medicine and Department of Pathology, University of Cape Town, Cape Town, South Africa.
- 5DSI-NRF Centre of Excellence for Biomedical Tuberculosis Research, South African Medical Research Council Centre for Tuberculosis Research, Division of Molecular Biology and Human Genetics, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.
Abstract
Background
Mycobacterium tuberculosis (MTB) disease is a global health threat with most cases occurring in low-and middle-income countries (LMIC) with limited healthcare infrastructure. Near-point-of-care testing deployed at peripheral clinical settings is needed to start treatment earlier and thereby improve treatment outcomes.Methods
We developed a rapid MTB detection assay for the DASH® Rapid PCR System with cartridge-based sample prep and dual target qPCR multicopy MTB insertion sequences IS6110 and IS1081 amplification. The limit of detection and analytical specificity of the RUO (research use only) DASH MTB assay were evaluated. Two clinical evaluations were performed using 110 (70 positive and 40 negative) de-identified blinded tongue swab specimens and 100 (49 positive and 51 negative) de-identified blinded sputum specimens from South African symptomatic clinic attendees.Results
The DASH assay demonstrated a limit of detection of 2.5 MTB cells/swab with no detection of 10 non-tuberculosis Mycobacterium strains. The clinical sensitivity of tongue swab specimens was 91%, and the specificity was 100% as compared to Xpert Ultra results on paired sputum specimens. The overall clinical sensitivity of sputum specimens was 96% (100% for smear-positive and 88% for smear-negative samples) and the specificity of 88% when compared to sputum culture. The DASH test is compatible with peripheral LMIC settings via external battery operation and cartridge stability at 45°C for one year.Conclusions
The DASH MTB's assay demonstrated high sensitivity and specificity, rapid time to result, and compatibility with environments that lack air conditioning and consistent electricity make this assay suitable for diverse clinical settings.
Related
- Development and evaluation of a multiplex PCR for simultaneous detection of Mycobacterium tuberculosis complex, Mycobacterium avium complex, and Burkholderia pseudomallei in clinical specimens
- Comparative Diagnostic Performance of Three Commercial Real‐Time PCR Assays for the Detection of Mycobacterium tuberculosis Complex in Bronchial Washing Specimens: A Large Retrospective Study
- Proteomic identification of Mycobacterium tuberculosis glycoproteins as potential biomarkers for active tuberculosis: Development of a prototype competitive ELISA for sputum antigen detection
- Near point‐of‐care nucleic acid amplification tests (NPOC‐NAATs) using respiratory specimens for detection of pulmonary tuberculosis
- Development of GuaB Inhibitors to Treat Mycobacterium tuberculosis Infection.
BibTeX
@article{butzler2026development,
title = {{Development of a Rapid Automated Point-of-Care Test for Mycobacterium tuberculosis Detection From Tongue Swabs and Sputum Specimens on the DASH® Rapid PCR System.}},
author = {Matthew A Butzler and Jennifer L Reed and Alaina M Olson and Rachel C Wood and Gerard A Cangelosi and Angelique K Luabeya and Mark Hatherill and Arthur M Chiwaya and Loren Rockman and Grant Theron and Sally M McFall},
journal = {Open forum infectious diseases},
year = {2026},
month = nov,
doi = {10.1093/ofid/ofag706},
url = {https://europepmc.org/article/MED/43048604},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Development of a Rapid Automated Point-of-Care Test for Mycobacterium tuberculosis Detection From Tongue Swabs and Sputum Specimens on the DASH® Rapid PCR System.
AU - Matthew A Butzler
AU - Jennifer L Reed
AU - Alaina M Olson
AU - Rachel C Wood
AU - Gerard A Cangelosi
AU - Angelique K Luabeya
AU - Mark Hatherill
AU - Arthur M Chiwaya
AU - Loren Rockman
AU - Grant Theron
AU - Sally M McFall
PY - 2026
DA - 2026/11/12
JO - Open forum infectious diseases
DO - 10.1093/ofid/ofag706
UR - https://europepmc.org/article/MED/43048604
AB - Background Mycobacterium tuberculosis (MTB) disease is a global health threat with most cases occurring in low-and middle-income countries (LMIC) with limited healthcare infrastructure. Near-point-of-care testing deployed at peripheral clinical settings is needed to start treatment earlier and thereby improve treatment outcomes.Methods We developed a rapid MTB detection assay for the DASH® Rapid PCR System with cartridge-based sample prep and dual target qPCR multicopy MTB insertion sequences IS6110 and IS1081 amplification. The limit of detection and analytical specificity of the RUO (research use only) DASH MTB assay were evaluated. Two clinical evaluations were performed using 110 (70 positive and 40 negative) de-identified blinded tongue swab specimens and 100 (49 positive and 51 negative) de-identified blinded sputum specimens from South African symptomatic clinic attendees.Results The DASH assay demonstrated a limit of detection of 2.5 MTB cells/swab with no detection of 10 non-tuberculosis Mycobacterium strains. The clinical sensitivity of tongue swab specimens was 91%, and the specificity was 100% as compared to Xpert Ultra results on paired sputum specimens. The overall clinical sensitivity of sputum specimens was 96% (100% for smear-positive and 88% for smear-negative samples) and the specificity of 88% when compared to sputum culture. The DASH test is compatible with peripheral LMIC settings via external battery operation and cartridge stability at 45°C for one year.Conclusions The DASH MTB's assay demonstrated high sensitivity and specificity, rapid time to result, and compatibility with environments that lack air conditioning and consistent electricity make this assay suitable for diverse clinical settings.
SN - 2328-8957
ER -