Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 11 min ago
Peer-reviewedCC BYOrthopaedic Journal of Sports Medicine

All-Inside Repair Tethered to the Popliteal Tendon is an Effective and Safe Option For the Treatment of Unstable Lateral Meniscus Injuries

  1. 1EPM-UNIFESP, SAO PAULO - SP – BRASIL
  2. 2INTO, RIO DE JANEIRO - RJ – BRASIL
  3. 3SCMSP - PAVILHAO FERNANDINHO SIMONSEN, SAO PAULO - SP - BRASIL

Abstract

Objective: To evaluate clinical outcomes, failure rates, and complications following all-inside lateral meniscus repair tethered to the popliteal tendon in patients with unstable lateral meniscus injuries. Methods: This retrospective case series included patients who underwent arthroscopic lateral meniscus repair tethered to the popliteal tendon using anchor-based all-inside device , with a ≥12months follow-up. Outcomes included failure and reoperation rates, complications, and patient-reported outcomes (PROs), including the International Knee Documentation Committee (IKDC), Lysholm, and Tegner scores. Patient acceptable symptomatic state (PASS) for IKDC was defined as ≥69.0. In patients with available paired preoperative and postoperative IKDC scores, improvement and minimal clinically important difference (MCID) achievement were assessed. Results: Forty-eight patients with a mean age of 30.9±10.9 years were included, with a mean follow-up of 35.1±13.2 months. Thirty-six patients underwent concomitant ACL reconstruction while 12 underwent isolated meniscal repair. Two patients required revision surgery for repair failure, corresponding to a 4.1% failure rate. No complications related to suture placement in the popliteal tendon were observed. At final follow-up, mean IKDC and Lysholm scores were 73.1 ± 16.9 and 84.5 ± 14.6, respectively, with 66.7% of patients achieving IKDC PASS. In the subset with paired IKDC data (n=20), mean improvement was 36.1±21.1points (p<0.001), and 85% achieved MCID. No significant difference was observed between pre-injury and postoperative Tegner scores. Conclusion: All-inside lateral meniscus repair tethered to the popliteal tendon represents an effective option for unstable lateral meniscus tears, with favorable short-to-midterm clinical outcomes and safety - exhibiting low failure rates, and no tendon-related complications.

Related

  1. All‐Inside Stabilization of Discoid Lateral Meniscus Popliteal Hiatus‐Related Instability Using Anterior Cord Release With Meniscus Retention
    Seikai Toyooka, Haruki Miyazaki, Yutoshi Osaki +3
    Arthroscopy techniquesPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCEurope PMCPMC
  2. The SCOUT agree: nitrofurantoin is safe and effective for first-line treatment of uncomplicated lower urinary tract infections in women.
    Bonnie C Prokesch, Philippe E Zimmern
    Translational andrology and urologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Ingavirin as a potentially effective treatment for coronavirus: An investigative study of patient outcomes
    Anahit Mkrtchyan, Hamzeh Ghorbani, Arsen Minasyan +5
    VirusDiseasePeer-reviewedLicence not statedFull text1 citedInfectious diseasePMC
  4. Unexpected positive intraoperative culture during supposed aseptic hip revision: Antibiotherapy is an effective and safe treatment. About 50 cases
    Guillaume Auberger, Pierre-Alban Bouché, Thomas Aubert +5
    SICOT-JPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Treatment of epistaxis in Osler-Weber-Rendu disease by bevacizumab nasal spray. The EROSB study: Determining the effective dose
    L. Vincent, L. Robard, C. Creveuil +3
    European Annals of Otorhinolaryngology, Head and Neck DiseasesPeer-reviewedLicence not stated3 citedGeneral biologyOncologyHAL
BibTeX
@article{padua2026allinside,
  title = {{All-Inside Repair Tethered to the Popliteal Tendon is an Effective and Safe Option For the Treatment of Unstable Lateral Meniscus Injuries}},
  author = {V.B.C. De Padua and E.S. Mameri and J.L.R. De Faria and P.B. Jorge and E.T. Rodrigues and C.E.D.S. Franciozi},
  journal = {Orthopaedic Journal of Sports Medicine},
  year = {2026},
  month = oct,
  doi = {10.1177/2325967126s00606},
  url = {https://doi.org/10.1177/2325967126s00606},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - All-Inside Repair Tethered to the Popliteal Tendon is an Effective and Safe Option For the Treatment of Unstable Lateral Meniscus Injuries
AU  - V.B.C. De Padua
AU  - E.S. Mameri
AU  - J.L.R. De Faria
AU  - P.B. Jorge
AU  - E.T. Rodrigues
AU  - C.E.D.S. Franciozi
PY  - 2026
DA  - 2026/10/28
JO  - Orthopaedic Journal of Sports Medicine
DO  - 10.1177/2325967126s00606
UR  - https://doi.org/10.1177/2325967126s00606
AB  - Objective: To evaluate clinical outcomes, failure rates, and complications following all-inside lateral meniscus repair tethered to the popliteal tendon in patients with unstable lateral meniscus injuries. Methods: This retrospective case series included patients who underwent arthroscopic lateral meniscus repair tethered to the popliteal tendon using anchor-based all-inside device , with a ≥12months follow-up. Outcomes included failure and reoperation rates, complications, and patient-reported outcomes (PROs), including the International Knee Documentation Committee (IKDC), Lysholm, and Tegner scores. Patient acceptable symptomatic state (PASS) for IKDC was defined as ≥69.0. In patients with available paired preoperative and postoperative IKDC scores, improvement and minimal clinically important difference (MCID) achievement were assessed. Results: Forty-eight patients with a mean age of 30.9±10.9 years were included, with a mean follow-up of 35.1±13.2 months. Thirty-six patients underwent concomitant ACL reconstruction while 12 underwent isolated meniscal repair. Two patients required revision surgery for repair failure, corresponding to a 4.1% failure rate. No complications related to suture placement in the popliteal tendon were observed. At final follow-up, mean IKDC and Lysholm scores were 73.1 ± 16.9 and 84.5 ± 14.6, respectively, with 66.7% of patients achieving IKDC PASS. In the subset with paired IKDC data (n=20), mean improvement was 36.1±21.1points (p<0.001), and 85% achieved MCID. No significant difference was observed between pre-injury and postoperative Tegner scores. Conclusion: All-inside lateral meniscus repair tethered to the popliteal tendon represents an effective option for unstable lateral meniscus tears, with favorable short-to-midterm clinical outcomes and safety - exhibiting low failure rates, and no tendon-related complications.
SN  - 2325-9671
ER  -