Skip to content
DraconiticResearch
Search Sources API
194,226 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BYBMC Oral Health

Influence of build orientation on the misfit and fracture load of three-unit 3D-printed permanent composite fixed dental prostheses

  1. 1Department of Prosthodontics, Faculty of Dentistry, Lokman Hekim University
  2. 2Department of Basic Medical Sciences, Faculty of Dentistry, Ankara University

Abstract

Background Additive manufacturing has expanded the clinical application of resin-based materials for definitive fixed dental prostheses (FDPs). This study aimed to evaluate the effect of different printing orientations on marginal and internal misfit, overall discrepancy, and fracture load of three-unit FDPs fabricated from a reinforced resin-based material (VarseoSmile TriniQ). Methods Forty-eight three-unit FDPs were fabricated and divided into four groups (n = 12): a lithium disilicate control group (IPS, IPS e.max CAD) and three experimental groups of a permanent composite resin (VST, VarseoSmile TriniQ) printed at 0°, 45°, and 90° build orientations (VST-0, VST-45, and VST-90). Marginal and internal misfit values were evaluated using micro-computed tomography (micro-CT) before and after chewing simulation. Dynamic aging was followed by fracture load testing using a single-load-to-failure protocol. Failure modes were classified under stereomicroscopic examination. Data were analyzed using nonparametric statistical methods. Intergroup comparisons were performed using the Kruskal-Wallis test with Dunn’s post hoc analysis, while pre- and post-aging comparisons were assessed using the Wilcoxon signed-rank test. Correlations between misfit parameters and fracture load were evaluated using Spearman’s rank correlation analysis (α = 0.05). Results Printing orientation significantly affected the marginal and internal misfit of TriniQ restorations. The 45° build orientation demonstrated the most consistent fit values both before and after the chewing simulation. Chewing simulation resulted in statistically significant increases in marginal, internal misfit as well as overall discrepancy values across all groups (p < 0.05). No statistically significant differences in fracture load were observed among the groups (p = 0.094). However, the IPS control group exhibited the highest Weibull modulus (m = 8.41). Spearman’s rank correlation analysis revealed no statistically significant correlations between fracture load and overall discrepancy in any group (p > 0.05). IPS restorations predominantly exhibited catastrophic brittle fractures, whereas TriniQ restorations mainly exhibited connector-related and deformation type failure patterns. Conclusions Build orientation influenced the adaptation accuracy of additively manufactured three unit FDPs, whereas no statistically significant differences in fracture load were observed among the groups. Minor variations in overall discrepancy did not appear to influence fracture load under static loading conditions. All tested groups exhibited fracture resistance values exceeding reported physiological masticatory forces. IPS e.max CAD restorations demonstrated higher structural reliability and more consistent, yet comparatively brittle, fracture behavior.

Related

  1. Digitally Guided Direct Composite Rehabilitation of a Maxillary Central Incisor Crown Fracture Associated With Multiple Diastemas: A 24-Month Clinical Case Report.
    Chang Liu, Binghua Lv, Huimin Nie +2
    Clinical case reportsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Quantifying the influence of a permanent shade pavilion structure on WBGT and activity modification.
    Andrew Grundstein, Susan Yeargin, Earl Cooper +2
    International journal of biometeorologyPeer-reviewedCC BYFull textPhysiologyEurope PMCPMC
  3. Hair Prostheses as a Complementary Therapeutic Option for Female Patients With Trichotillomania
    Marcelo de Souza Teixeira, Kamila Casagrande, Maria Cristina Cardoso Mendonça +1
    Dermatology Practical & ConceptualPeer-reviewedCC BY-NCFull textGeneral medicineDOAJ
  4. Clinical Performance and Survival Outcomes of All-on-4 Full-Arch Implant-Supported Prostheses in Patients With a Completely Edentulous Arch: A Retrospective Cohort Study
    Jay Gohil, Mohammed Taslim Fathima, Dilip Chakravarthy +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Interocclusal Recording for Implant-Supported Fixed Prostheses: Current Materials, Clinical Techniques and Digital Workflows.
    Nezha Ben El Hammi, Iman Ihoum, Abdallah Mouhibi
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
BibTeX
@article{ozer2026influence,
  title = {{Influence of build orientation on the misfit and fracture load of three-unit 3D-printed permanent composite fixed dental prostheses}},
  author = {Nazire Esra Ozer and Zeynep Sahin and Arda Buyuksungur and Mehmet Ali Kilicarslan},
  journal = {BMC Oral Health},
  year = {2026},
  month = jul,
  doi = {10.1186/s12903-026-09183-9},
  url = {https://doi.org/10.1186/s12903-026-09183-9},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Influence of build orientation on the misfit and fracture load of three-unit 3D-printed permanent composite fixed dental prostheses
AU  - Nazire Esra Ozer
AU  - Zeynep Sahin
AU  - Arda Buyuksungur
AU  - Mehmet Ali Kilicarslan
PY  - 2026
DA  - 2026/07/01
JO  - BMC Oral Health
DO  - 10.1186/s12903-026-09183-9
UR  - https://doi.org/10.1186/s12903-026-09183-9
AB  - Background Additive manufacturing has expanded the clinical application of resin-based materials for definitive fixed dental prostheses (FDPs). This study aimed to evaluate the effect of different printing orientations on marginal and internal misfit, overall discrepancy, and fracture load of three-unit FDPs fabricated from a reinforced resin-based material (VarseoSmile TriniQ). Methods Forty-eight three-unit FDPs were fabricated and divided into four groups (n = 12): a lithium disilicate control group (IPS, IPS e.max CAD) and three experimental groups of a permanent composite resin (VST, VarseoSmile TriniQ) printed at 0°, 45°, and 90° build orientations (VST-0, VST-45, and VST-90). Marginal and internal misfit values were evaluated using micro-computed tomography (micro-CT) before and after chewing simulation. Dynamic aging was followed by fracture load testing using a single-load-to-failure protocol. Failure modes were classified under stereomicroscopic examination. Data were analyzed using nonparametric statistical methods. Intergroup comparisons were performed using the Kruskal-Wallis test with Dunn’s post hoc analysis, while pre- and post-aging comparisons were assessed using the Wilcoxon signed-rank test. Correlations between misfit parameters and fracture load were evaluated using Spearman’s rank correlation analysis (α = 0.05). Results Printing orientation significantly affected the marginal and internal misfit of TriniQ restorations. The 45° build orientation demonstrated the most consistent fit values both before and after the chewing simulation. Chewing simulation resulted in statistically significant increases in marginal, internal misfit as well as overall discrepancy values across all groups (p < 0.05). No statistically significant differences in fracture load were observed among the groups (p = 0.094). However, the IPS control group exhibited the highest Weibull modulus (m = 8.41). Spearman’s rank correlation analysis revealed no statistically significant correlations between fracture load and overall discrepancy in any group (p > 0.05). IPS restorations predominantly exhibited catastrophic brittle fractures, whereas TriniQ restorations mainly exhibited connector-related and deformation type failure patterns. Conclusions Build orientation influenced the adaptation accuracy of additively manufactured three unit FDPs, whereas no statistically significant differences in fracture load were observed among the groups. Minor variations in overall discrepancy did not appear to influence fracture load under static loading conditions. All tested groups exhibited fracture resistance values exceeding reported physiological masticatory forces. IPS e.max CAD restorations demonstrated higher structural reliability and more consistent, yet comparatively brittle, fracture behavior.
SN  - 1472-6831
ER  -