Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport
- 1Birla Institute of Technology and Science (BITS) Pilani , , Hyderabad Campus , , ,
- 2National Institute of Technology (NIT) , , , ,
Abstract
The combined effect of geometric obstruction and auxiliary inlet on sensor response time for a microfluidics-integrated biosensor has been numerically investigated in this study. The flow behavior and mass transfer of an analyte have been modeled using incompressible Navier–Stokes equations coupled with convection–diffusion and Langmuir adsorption kinetics equations for comparable time scales of diffusion and surface reaction. Introduction of a block increases the analyte velocity near the sensor surface with subsequent reduction in diffusion boundary layer thickness, thereby ameliorating the sensor response time. Insertion of an auxiliary inlet diminishes the sensor response time to a greater extent by confining a thin layer of analyte above the sensor surface. A systematic parametric study is conducted to evaluate the blended effects of block height, block position, block width, auxiliary inlet position, and auxiliary inlet velocity on sensor performance. Taguchi-based optimization techniques employing an L27 orthogonal array alongside signal-to-noise ratio analysis and analysis of variance have been utilized for identification of optimal parameter combinations. The results indicate that the auxiliary inlet velocity is the most influential parameter with a contribution of 65.8% toward the decrement in sensor response time. The findings demonstrate that the combination of block-induced flow-field modifications and auxiliary-inlet-mediated flow confinement effect significantly augments analyte transport to the sensor surface, thereby decreasing the sensor response time by approximately 92% in comparison to the scenario devoid of a block and auxiliary inlet. This study provides valuable insights for the design and optimization of point-of-care microfluidic devices with reduced detection time.
Related
- A species-resolved well-balanced lattice Boltzmann framework for Maxwell–Stefan diffusion in non-ideal multiphase multicomponent transport
- Optimization of CNT-induced Ni₉S₈ nanoplates for balanced charge-transfer kinetics and conductivity in high-performance battery-type supercapacitors.
- Warm Isostatic vs. Cold Uniaxial Pressing in All-Solid-State Battery Cathodes: Linking Microstructure, Transport, and Mechano-Electrochemical Response
- Optimization and Evaluation of Polymer Inclusion Membrane (PIM) Containing 10% Copoly Eugenol Divinyl Benzene as Carrier Compound for Malachite Green Transport
- Two-Stage Optimization of Oleic Acid Esterification via Response Surface Methodology and Green Chemistry Metrics Selection for Biodiesel from WCO
BibTeX
@article{muralikrishna2026optimization,
title = {{Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport}},
author = {N Muralikrishna and Sayan Das and Somnath Santra and Parikshit Sahatiya and Arnab Guha},
journal = {ACS Omega},
year = {2026},
month = nov,
doi = {10.1021/acsomega.6c12419},
url = {https://pubs.acs.org/acsodf/article/doi/10.1021/acsomega.6c12419/5471483/Optimization-of-Sensor-Response-Time-in},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport
AU - N Muralikrishna
AU - Sayan Das
AU - Somnath Santra
AU - Parikshit Sahatiya
AU - Arnab Guha
PY - 2026
DA - 2026/11/17
JO - ACS Omega
DO - 10.1021/acsomega.6c12419
UR - https://pubs.acs.org/acsodf/article/doi/10.1021/acsomega.6c12419/5471483/Optimization-of-Sensor-Response-Time-in
AB - The combined effect of geometric obstruction and auxiliary inlet on sensor response time for a microfluidics-integrated biosensor has been numerically investigated in this study. The flow behavior and mass transfer of an analyte have been modeled using incompressible Navier–Stokes equations coupled with convection–diffusion and Langmuir adsorption kinetics equations for comparable time scales of diffusion and surface reaction. Introduction of a block increases the analyte velocity near the sensor surface with subsequent reduction in diffusion boundary layer thickness, thereby ameliorating the sensor response time. Insertion of an auxiliary inlet diminishes the sensor response time to a greater extent by confining a thin layer of analyte above the sensor surface. A systematic parametric study is conducted to evaluate the blended effects of block height, block position, block width, auxiliary inlet position, and auxiliary inlet velocity on sensor performance. Taguchi-based optimization techniques employing an L27 orthogonal array alongside signal-to-noise ratio analysis and analysis of variance have been utilized for identification of optimal parameter combinations. The results indicate that the auxiliary inlet velocity is the most influential parameter with a contribution of 65.8% toward the decrement in sensor response time. The findings demonstrate that the combination of block-induced flow-field modifications and auxiliary-inlet-mediated flow confinement effect significantly augments analyte transport to the sensor surface, thereby decreasing the sensor response time by approximately 92% in comparison to the scenario devoid of a block and auxiliary inlet. This study provides valuable insights for the design and optimization of point-of-care microfluidic devices with reduced detection time.
SN - 2470-1343
ER -