Skip to content
DraconiticResearch
Search Sources API
190,839 studies31 sourcesUpdated 28 min ago
Peer-reviewedCC BY-NCERJ open research

Low end-tidal carbon dioxide identifies high-severity pulmonary embolism and shock-level haemodynamics.

4 affiliations
  1. 1Department of Pulmonary and Critical Care, Lankenau Medical Center, Main Line Health, Wynnewood, PA, USA.
  2. 2Department of Interventional Cardiology, Lankenau Medical Center, Main Line Health, Wynnewood, PA, USA.
  3. 3Department of Emergency Medicine, Lankenau Medical Center, Main Line Health, Wynnewood, PA, USA.
  4. 4Main Line Health Center for Population Research, Main Line Health, Wynnewood, PA, USA.

Abstract

Background

End-tidal carbon dioxide tension (P ETCO₂ ) may be reduced when lung units are ventilated but under-perfused, as occurs in pulmonary embolism (PE). We sought to determine whether early P ETCO₂ measurement reflects PE severity according to European Society of Cardiology (ESC) risk categories and identifies shock-level haemodynamics among patients undergoing catheter-directed therapy (CDT).Methods

Patients admitted with acute PE confirmed by computed tomography pulmonary angiography were enrolled in this prospective observational study. P ETCO₂ was measured using nasal capnography within 24 h of presentation or immediately prior to urgent CDT. P ETCO₂ was compared between lower and higher severity PE groups and between patients referred for CDT or not. In patients undergoing mechanical thrombectomy (CDT) with invasive haemodynamic assessment, pulmonary arterial pressures and cardiac indices were recorded. A subgroup analysis evaluated patients with cardiogenic shock defined as cardiac index ≤1.8 L·min⁻¹·m⁻².Results

62 patients were analysed. P ETCO₂ was significantly lower in the combined higher risk group compared to the combined lower risk group (mean 21.7 (95% CI 20.2-23.3) versus 30.2 (95% CI 27.8-32.6) mmHg; p<0.001). P ETCO₂ was also lower in patients referred for CDT compared to those not referred (mean 20.4 (95% CI 18.7-22.0) versus 28.2 (95% CI 26.2-30.1) mmHg; p<0.001). Among patients who underwent CDT and met haemodynamic criteria for cardiogenic shock (n=16), P ETCO₂ was the lowest (mean 18.6 (95% CI 16.1-21.1) mmHg).Conclusions

P ETCO₂ can be rapidly obtained early in PE evaluation and reflects ESC-defined severity. A P ETCO₂ level <20 mmHg was associated with shock-level haemodynamics among normotensive intermediate-high-risk patients undergoing CDT. P ETCO₂ may serve as a non-invasive marker of physiological severity.

Related

  1. Routine contrast-enhanced CT screening identifies asymptomatic pulmonary embolism after minimally invasive esophagectomy: incidence and associated factors
    Akira Saito, Tomotake Ariyoshi, Satoru Goto +6
    EsophagusPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  2. Obstructive Sleep Apnea and Pulmonary Embolism: Prevalence, Severity and the Association of Sleep-Disordered Breathing with Thromboembolic Disease
    Patricia Pérez-Ferrer, Eusebi Chiner, Ignacio Boira +3
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textPhysiologyCrossrefEurope PMC
  3. Pulmonary Haemodynamics After Mechanical Therapy With PEA and BPA Predict Survival in Patients With CTEPH ‐ A Prospective Analysis From the National UK CURATE Registry
    Eilish Turner‐Frick, Hakim Ghani, Paula Appenzeller +17
    Pulmonary circulationPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. From bradyarrhythmia to embolism: A rare case of acute pulmonary embolism immediately after pacemaker implantation.
    Iwan Cahyo Santosa Putra, Jordan Budiono, Raymond Pranata +5
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  5. Diagnostic challenge of pulmonary embolism during testosterone replacement therapy for primary hypogonadism
    JCEM case reportsPeer-reviewedCC BYFull textEndocrinology & metabolismEurope PMC
BibTeX
@article{greenspon2026endtidal,
  title = {{Low end-tidal carbon dioxide identifies high-severity pulmonary embolism and shock-level haemodynamics.}},
  author = {Lee W Greenspon and Patrick Ho and Jason George and Spencer Whealon and Margarita Gianniosis and Betsy Develin and Jonathan Fischer and Stephanie Kjelstrom and Mara Caroline and Eric Gnall},
  journal = {ERJ open research},
  year = {2026},
  month = sep,
  doi = {10.1183/23120541.00062-2026},
  url = {https://europepmc.org/article/MED/42899109},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Low end-tidal carbon dioxide identifies high-severity pulmonary embolism and shock-level haemodynamics.
AU  - Lee W Greenspon
AU  - Patrick Ho
AU  - Jason George
AU  - Spencer Whealon
AU  - Margarita Gianniosis
AU  - Betsy Develin
AU  - Jonathan Fischer
AU  - Stephanie Kjelstrom
AU  - Mara Caroline
AU  - Eric Gnall
PY  - 2026
DA  - 2026/09/01
JO  - ERJ open research
DO  - 10.1183/23120541.00062-2026
UR  - https://europepmc.org/article/MED/42899109
AB  - Background  End-tidal carbon dioxide tension (P ETCO₂ ) may be reduced when lung units are ventilated but under-perfused, as occurs in pulmonary embolism (PE). We sought to determine whether early P ETCO₂ measurement reflects PE severity according to European Society of Cardiology (ESC) risk categories and identifies shock-level haemodynamics among patients undergoing catheter-directed therapy (CDT).Methods  Patients admitted with acute PE confirmed by computed tomography pulmonary angiography were enrolled in this prospective observational study. P ETCO₂ was measured using nasal capnography within 24 h of presentation or immediately prior to urgent CDT. P ETCO₂ was compared between lower and higher severity PE groups and between patients referred for CDT or not. In patients undergoing mechanical thrombectomy (CDT) with invasive haemodynamic assessment, pulmonary arterial pressures and cardiac indices were recorded. A subgroup analysis evaluated patients with cardiogenic shock defined as cardiac index ≤1.8 L·min⁻¹·m⁻².Results  62 patients were analysed. P ETCO₂ was significantly lower in the combined higher risk group compared to the combined lower risk group (mean 21.7 (95% CI 20.2-23.3) versus 30.2 (95% CI 27.8-32.6) mmHg; p<0.001). P ETCO₂ was also lower in patients referred for CDT compared to those not referred (mean 20.4 (95% CI 18.7-22.0) versus 28.2 (95% CI 26.2-30.1) mmHg; p<0.001). Among patients who underwent CDT and met haemodynamic criteria for cardiogenic shock (n=16), P ETCO₂ was the lowest (mean 18.6 (95% CI 16.1-21.1) mmHg).Conclusions  P ETCO₂ can be rapidly obtained early in PE evaluation and reflects ESC-defined severity. A P ETCO₂ level <20 mmHg was associated with shock-level haemodynamics among normotensive intermediate-high-risk patients undergoing CDT. P ETCO₂ may serve as a non-invasive marker of physiological severity.
SN  - 2312-0541
ER  -