Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 17 min ago
Peer-reviewedCC BYApplied Sciences

Parametric Influence and Mechanical Performance Analysis of Large-Span Composite Floor System with a Bidirectional Dense-Rib Steel Beam-Lightweight Concrete Slab

  1. 1School of Civil Engineering and Architecture, Hainan University, Haikou 570228, China

Abstract

Based on the SI (Skeleton-Infill) concept, which separates the load-bearing structure from the infill system, achieving large open spaces and flexible partition layouts is essential for green buildings to adapt to varying household sizes and to reduce the construction costs associated with industrialized building systems. Therefore, this paper proposes a novel large-span composite floor system intended for steel-framed residential buildings. The system consists of bidirectional dense-rib steel beams, a lightweight concrete slab, and an OSB (Oriented Strand Board) ceiling panel, which serves as both the ceiling finish and a structural tension component, and features low self-weight and flexible interior space layouts. Using the finite element method, the influence of key parameters on the vertical stiffness, fundamental frequency, and stress distribution of the floor is systematically analyzed. The results show that the components of the floor system can work compositely, and the optimal design parameters are as follows: dense-rib steel beam spacing of 1.5 m, secondary column spacing of 2 m, and stud spacing of less than or equal to 200 mm. Under serviceability conditions, the mid-span deflection of the floor meets the specification limit, the first-order vertical natural frequency is greater than 4 Hz, and the OSB panel can provide a certain bearing capacity reserve and improve the overall stiffness. The floor system not only meets the national standard requirements for deflection and vibration comfort but also has good load-bearing performance, which can meet the adaptability requirements and provide a reference for the design.

Related

  1. Design and Mechanical Performance of Cylindrical-Coordinate Ti-6Al-4V Octet Lattices: Influence of Outer-Shell Hybridization and Strut Diameter on Compressive Strength
    Constantin Romică Stoica, Alexandru Paraschiv, Vladimir-Ioan Petrescu +1
    Applied SciencesPeer-reviewedCC BYFull textGeneral biologyGeneral chemistryDOAJ
  2. DTL-YOLO: a lightweight model for real-time tobacco leaf damage detection and mechanical harvesting quality assessment
    Yue Luo, Jun Yang, Chenhui Zhu +3
    Frontiers in Plant SciencePeer-reviewedCC BY 4.0Full textPlant biologyCrossrefEurope PMCPMC
  3. Influence of 3D-Printing system on the mechanical and surface properties of a 3D-Printed denture base resin
    Raghdah M. Alshaibani, Yuwei Fan, Russell Giordano II +2
    Journal of Applied Biomaterials & Functional MaterialsPeer-reviewedCC BYFull textSystems & synthetic biologyDOAJ
  4. Influence of water content and organic matter on the mechanical strength characteristics of municipal sewage sludge
    Ruimin Yang, Jiadong Ma, Zhenning Zhang +1
    PLOS OnePeer-reviewedCC BYFull textGeneral biologyMaterials & polymersPLOSEurope PMCPMC
  5. The Influence of Microbial Fermentation on Growth Performance, Protein Solubility, and Lipid Modulation in the Black Soldier Fly (Hermetia illucens) Larvae
    Hafiza Mehwish Malik, Khurshied Ahmed Khan, Khurram Yousaf +4
    InsectsPeer-reviewedCC BYFull textGeneral biologyEurope PMC
BibTeX
@article{fan2026parametric,
  title = {{Parametric Influence and Mechanical Performance Analysis of Large-Span Composite Floor System with a Bidirectional Dense-Rib Steel Beam-Lightweight Concrete Slab}},
  author = {Yongquan Fan and Baoshi Jiang},
  journal = {Applied Sciences},
  year = {2026},
  month = nov,
  doi = {10.3390/app162211480},
  url = {https://doi.org/10.3390/app162211480},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Parametric Influence and Mechanical Performance Analysis of Large-Span Composite Floor System with a Bidirectional Dense-Rib Steel Beam-Lightweight Concrete Slab
AU  - Yongquan Fan
AU  - Baoshi Jiang
PY  - 2026
DA  - 2026/11/25
JO  - Applied Sciences
DO  - 10.3390/app162211480
UR  - https://doi.org/10.3390/app162211480
AB  - Based on the SI (Skeleton-Infill) concept, which separates the load-bearing structure from the infill system, achieving large open spaces and flexible partition layouts is essential for green buildings to adapt to varying household sizes and to reduce the construction costs associated with industrialized building systems. Therefore, this paper proposes a novel large-span composite floor system intended for steel-framed residential buildings. The system consists of bidirectional dense-rib steel beams, a lightweight concrete slab, and an OSB (Oriented Strand Board) ceiling panel, which serves as both the ceiling finish and a structural tension component, and features low self-weight and flexible interior space layouts. Using the finite element method, the influence of key parameters on the vertical stiffness, fundamental frequency, and stress distribution of the floor is systematically analyzed. The results show that the components of the floor system can work compositely, and the optimal design parameters are as follows: dense-rib steel beam spacing of 1.5 m, secondary column spacing of 2 m, and stud spacing of less than or equal to 200 mm. Under serviceability conditions, the mid-span deflection of the floor meets the specification limit, the first-order vertical natural frequency is greater than 4 Hz, and the OSB panel can provide a certain bearing capacity reserve and improve the overall stiffness. The floor system not only meets the national standard requirements for deflection and vibration comfort but also has good load-bearing performance, which can meet the adaptability requirements and provide a reference for the design.
SN  - 2076-3417
ER  -