Novel endovascular management of a displaced aortic endograft component during transcatheter aortic valve replacement
7 affiliations
- 1Vanderbilt University Medical Center, Nashville, TN
- 2Vanderbilt University School of Medicine, Nashville, TN
- 3Division of Cardiovascular Medicine, Vanderbilt University Medical Center, Nashville, TN
- 4Department of Cardiothoracic Surgery, Vanderbilt University Medical Center, Nashville, TN
- 5Tennessee Valley VA Health System, Nashville, TN
- 6Meharry Medical College, Nashville, TN
- 7Department of Vascular Surgery, Vanderbilt University Medical Center, Nashville, TN
Abstract
We report the case of a 73-year-old man with prior endovascular aneurysm repair (EVAR) of the abdominal aorta complicated by type Ia endoleak requiring two proximal aortic cuffs. Ten years later, he underwent transfemoral transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. During the delivery of the transcatheter aortic valve replacement device, one of the aortic cuffs was displaced into the distal thoracic aorta. This case report describes a rare complication of delayed device displacement during TAVR and demonstrates a novel strategy for endovascular salvage. It highlights the opportunity for endovascular repair during TAVR planning in patients with prior aortic stent grafts. In addition, close multidisciplinary collaboration is valuable for managing unexpected device interactions.
Related
- Staged open ascending aortic replacement and endovascular total arch repair using a three-inner-branch physician-modified endograft for chronic postdissection aneurysms.
- Six-Year Survival without Open Conversion after Repeat Endovascular Repair for Rupture Associated with Endograft Infection following EVAR: A Case Report.
- Case Report: Multiorgan arterial and venous thrombosis after ischemic stroke: endovascular management and subsequent transcatheter patent foramen ovale closure
- Staged Management with Transcatheter Aortic Valve Replacement in a Patient with ST-Segment Elevation Myocardial Infarction, Low-Gradient Aortic Stenosis, and Recurrent Cardiogenic Shock: A Case Report
- Hybrid approach with thoracic endovascular treatment and abdominal aortic replacement for acute type B aortic dissection complicated by ruptured abdominal aortic aneurysm
BibTeX
@article{vyas2026novel,
title = {{Novel endovascular management of a displaced aortic endograft component during transcatheter aortic valve replacement}},
author = {Punit Vyas and Grant Woodruff and Andre Hall and Kashish Goel and Brian Lima and John Curci},
journal = {Journal of Vascular Surgery Cases, Innovations and Techniques},
year = {2026},
month = sep,
doi = {10.1016/j.jvscit.2026.102534},
url = {https://doi.org/10.1016/j.jvscit.2026.102534},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Novel endovascular management of a displaced aortic endograft component during transcatheter aortic valve replacement
AU - Punit Vyas
AU - Grant Woodruff
AU - Andre Hall
AU - Kashish Goel
AU - Brian Lima
AU - John Curci
PY - 2026
DA - 2026/09/28
JO - Journal of Vascular Surgery Cases, Innovations and Techniques
DO - 10.1016/j.jvscit.2026.102534
UR - https://doi.org/10.1016/j.jvscit.2026.102534
AB - We report the case of a 73-year-old man with prior endovascular aneurysm repair (EVAR) of the abdominal aorta complicated by type Ia endoleak requiring two proximal aortic cuffs. Ten years later, he underwent transfemoral transcatheter aortic valve replacement (TAVR) for severe aortic stenosis. During the delivery of the transcatheter aortic valve replacement device, one of the aortic cuffs was displaced into the distal thoracic aorta. This case report describes a rare complication of delayed device displacement during TAVR and demonstrates a novel strategy for endovascular salvage. It highlights the opportunity for endovascular repair during TAVR planning in patients with prior aortic stent grafts. In addition, close multidisciplinary collaboration is valuable for managing unexpected device interactions.
SN - 2468-4287
ER -