Human-organ-scale x-ray fluorescence ghost imaging for radioisotope-free diagnostics
- 1Physics Department, Institute of Nanotechnology and Advanced Materials, Bar-Ilan University
- 2Université Grenoble Alpes, CEA, IRIG-MEM
Abstract
A wide range of diagnostic information in medicine is currently obtained using radioactive tracers. While central to nuclear medicine, these methods face inherent limitations: radiation dose restricts repeat examinations, short tracer half-lives and complex logistics limit accessibility and increase costs, and relatively low spatial resolution often necessitates complementary CT or MRI. Here we present a first proof-of-concept demonstration of an alternative imaging modality based on x-ray fluorescence (XRF) computational ghost imaging (CGI) at the human-organ scale. Using a thyroid phantom filled with iodine solution as a model system, we show that structured illuminations combined with fluorescence detection reconstruct the iodine distribution with high fidelity. This approach avoids the use of radioactive tracers while preserving key aspects of the image structure and contrast. We report a spatial resolution of ~ 4.5 mm in the current implementation, with potential for further improvement through system optimization. Beyond this demonstration, XRF-CGI establishes a generalizable framework for tracer imaging without radionuclides, opening a route toward safer, repeatable, and more accessible diagnostics.
Related
- Optimizing x-ray based multimodal imaging: investigating dose dependency and modulation of fluorescence emission from GdF ₃ nanoparticles doped with terbium using spectral photon counting CT
- Rapid and high-sensitive NV-based microwave field imaging via digital lock-in amplification for on-chip microstrip diagnostics
- Scattering-force-driven light-sheet fluorescence microscopy for scan-free three-dimensional imaging
- PyFLI: A Python Library for Simulation, Parameter Estimation, and Benchmarking in Fluorescence Lifetime Imaging
- Dual deconvolution multifocal fluorescence response matrix microscopy for aberration-free high-throughput super-resolution imaging
BibTeX
@article{levinson2026humanorganscale,
title = {{Human-organ-scale x-ray fluorescence ghost imaging for radioisotope-free diagnostics}},
author = {Eli Levinson and Rachel H. Shukrun and Nicola Viganò and Sharon Shwartz},
journal = {Scientific Reports},
year = {2026},
month = jul,
doi = {10.1038/s41598-026-62593-1},
url = {https://doi.org/10.1038/s41598-026-62593-1},
note = {CC BY},
}
RIS
TY - JOUR
TI - Human-organ-scale x-ray fluorescence ghost imaging for radioisotope-free diagnostics
AU - Eli Levinson
AU - Rachel H. Shukrun
AU - Nicola Viganò
AU - Sharon Shwartz
PY - 2026
DA - 2026/07/01
JO - Scientific Reports
DO - 10.1038/s41598-026-62593-1
UR - https://doi.org/10.1038/s41598-026-62593-1
AB - A wide range of diagnostic information in medicine is currently obtained using radioactive tracers. While central to nuclear medicine, these methods face inherent limitations: radiation dose restricts repeat examinations, short tracer half-lives and complex logistics limit accessibility and increase costs, and relatively low spatial resolution often necessitates complementary CT or MRI. Here we present a first proof-of-concept demonstration of an alternative imaging modality based on x-ray fluorescence (XRF) computational ghost imaging (CGI) at the human-organ scale. Using a thyroid phantom filled with iodine solution as a model system, we show that structured illuminations combined with fluorescence detection reconstruct the iodine distribution with high fidelity. This approach avoids the use of radioactive tracers while preserving key aspects of the image structure and contrast. We report a spatial resolution of ~ 4.5 mm in the current implementation, with potential for further improvement through system optimization. Beyond this demonstration, XRF-CGI establishes a generalizable framework for tracer imaging without radionuclides, opening a route toward safer, repeatable, and more accessible diagnostics.
SN - 2045-2322
ER -