NTL amplification in a SuperCDMS-style detector fabricated from a University of South Dakota-grown germanium crystal

Abstract

Neganov-Trofimov-Luke (NTL) amplification enables eV-sub-keV detection thresholds for low-mass dark-matter and coherent elastic neutrino-nucleus scattering experiments. We evaluated two University of South Dakota (USD)-grown germanium crystals fabricated as SuperCDMS-style four-channel athermal-phonon detectors and operated near 10 mK. The crystals had electrically active impurity concentrations near 1010 ^−3 and etch-pit densities of $300−7000~\mathrm^-2$. Contact-free biasing produced no resolvable amplification. However, after depositing a 600 nm aluminum bias contact, Detector~2 exhibited clear voltage-dependent NTL gain. The reconstructed channel-B energy increased from approximately 3.9 keV at 0 V to 34.9 keV at 40 V, corresponding to an 8.9-fold enhancement. Statistical centroid uncertainties were below 0.3%, while low-bias fits yielded effective prompt- and NTL-phonon response coefficients of (6.77±0.82)% and (4.77±0.20)%, respectively, excluding systematic uncertainties. These results demonstrate the feasibility of USD-grown germanium for SuperCDMS-style high-voltage phonon detectors and highlight the importance of both crystal quality and contact fabrication in achieving NTL amplification.

Related

  1. Calibration and Performance of Germanium High Voltage Detectors for SuperCDMS SNOLAB
    M. F. Albakry, I. Alkhatib, D. Alonso-González +141
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  2. Low Frequency Noise Identification for the SuperCDMS Experiment using Convolutional Neural Networks
    SuperCDMS collaboration, M. F. Albakry, I. Alkhatib +124
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  3. Heavy-Hole--Light-Hole Mixing and Spin--Photon Coupling in Germanium Flopping-Mode Qubits
    Jose Reina-Gálvez, Guido Burkard
    arXivPreprintCC BY 4.0Full textCondensed matterQuantum physics & quantum informationarXiv
  4. Super-Lindhard Ionization from 254 eVnr Nuclear Recoils in Germanium
    A. R. L. Kavner, E. Todd, M. Babicz +11
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
  5. High significance measurement of reactor coherent elastic neutrino-nucleus scattering on germanium by CONUS+
    N. Ackermann, H. Bonet, C. Buck +16
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
BibTeX
@misc{mei2026amplification,
  title = {{NTL amplification in a SuperCDMS-style detector fabricated from a University of South Dakota-grown germanium crystal}},
  author = {Dongming Mei and Gerardo Gonzalez and William Baker and Mark Platt and Nader Mirabolfathi},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.29973},
  eprint = {2610.29973},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.29973},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - NTL amplification in a SuperCDMS-style detector fabricated from a University of South Dakota-grown germanium crystal
AU  - Dongming Mei
AU  - Gerardo Gonzalez
AU  - William Baker
AU  - Mark Platt
AU  - Nader Mirabolfathi
PY  - 2026
DA  - 2026/10/21
PB  - arXiv
DO  - 10.48550/arxiv.2610.29973
UR  - https://arxiv.org/abs/2610.29973
AB  - Neganov-Trofimov-Luke (NTL) amplification enables eV-sub-keV detection thresholds for low-mass dark-matter and coherent elastic neutrino-nucleus scattering experiments. We evaluated two University of South Dakota (USD)-grown germanium crystals fabricated as SuperCDMS-style four-channel athermal-phonon detectors and operated near 10 mK. The crystals had electrically active impurity concentrations near 10^10 ^−3 and etch-pit densities of $300−7000~\mathrm^-2$. Contact-free biasing produced no resolvable amplification. However, after depositing a 600 nm aluminum bias contact, Detector~2 exhibited clear voltage-dependent NTL gain. The reconstructed channel-B energy increased from approximately 3.9 keV at 0 V to 34.9 keV at 40 V, corresponding to an 8.9-fold enhancement. Statistical centroid uncertainties were below 0.3%, while low-bias fits yielded effective prompt- and NTL-phonon response coefficients of (6.77±0.82)% and (4.77±0.20)%, respectively, excluding systematic uncertainties. These results demonstrate the feasibility of USD-grown germanium for SuperCDMS-style high-voltage phonon detectors and highlight the importance of both crystal quality and contact fabrication in achieving NTL amplification.
ER  -