Advanced Membrane Processes for the Removal of Anthelmintics, Neonicotinoids and Their Mixtures: Retention Mechanisms and Effects on Ecotoxicity.
- 1Department of Analytical Chemistry, University of Zagreb Faculty of Chemical Engineering and Technology, Marulićev trg 19, 10000 Zagreb, Croatia.
- 2Department of Physical Chemistry, University of Zagreb Faculty of Chemical Engineering and Technology, Marulićev trg 19, 10000 Zagreb, Croatia.
Abstract
Veterinary anthelmintics and neonicotinoid insecticides in aquatic environments pose challenges for conventional wastewater treatment. Six commercial ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO) membranes were evaluated for the rejection of three veterinary anthelmintics (albendazole, febantel, and mebendazole) and three neonicotinoid insecticides (acetamiprid, clothianidin, and thiacloprid). The compounds were tested individually and as a six-component mixture in demineralized and model water. After 3 h, rejection of the individual compounds was at least 92.9% with the tight NF membrane ESNA1-LF-LD and 94.1% with the RO membrane ESPA4. Neonicotinoid rejection by the UF membrane did not exceed 9.2%. In the six-component mixture, ESNA1-LF-LD rejected 87.9-94.9% of neonicotinoids and 90.1% to >99.9% of anthelmintics. The RO membranes (XLE and ESPA4) rejected 89.8-94.8% of neonicotinoids and 92.5% to >99.9% of anthelmintics. Fourier transform infrared (FTIR) spectroscopy indicated possible interactions between anthelmintics and the membranes. At the highest sample volume fraction tested, the untreated mixture caused 63.6% inhibition of Vibrio fischeri bioluminescence in demineralized water and 86.8% in model water. No inhibition was detected in the XLE or ESPA4 permeates. Rejection depended on membrane selectivity, compound properties, and water matrix. Combining chemical measurements with ecotoxicity assays provided a broader assessment of membrane treatment performance.
Related
- Effects of typical emerging pollutants on biological treatment systems: processes, mechanisms, and recovery strategies
- Degradation pathways and in silico ecotoxicity assessment of meropenem by-products generated by electrochemical oxidation
- Ecotoxicity and interactions of micro- and nano-plastics in aquatic environments: advancing towards standardized mitigation approaches
- Microplastics as evolving particle–chemical–microbial interfaces: plastisphere ecology, ecotoxicity, and safety-informed remediation
- Transport, retention and degradation of the urban biocides terbutryn, diuron and octylisothiazolinone and the herbicide acetochlor in urban surface-soil interfaces
BibTeX
@article{viskovic2026advanced,
title = {{Advanced Membrane Processes for the Removal of Anthelmintics, Neonicotinoids and Their Mixtures: Retention Mechanisms and Effects on Ecotoxicity.}},
author = {Bruna Babić Visković and Petra Mustapić and Veronika Stepan and Danijela Ašperger and Davor Dolar},
journal = {Membranes},
year = {2026},
month = nov,
doi = {10.3390/membranes16110395},
url = {https://europepmc.org/article/MED/43083218},
note = {CC BY},
}
RIS
TY - JOUR
TI - Advanced Membrane Processes for the Removal of Anthelmintics, Neonicotinoids and Their Mixtures: Retention Mechanisms and Effects on Ecotoxicity.
AU - Bruna Babić Visković
AU - Petra Mustapić
AU - Veronika Stepan
AU - Danijela Ašperger
AU - Davor Dolar
PY - 2026
DA - 2026/11/20
JO - Membranes
DO - 10.3390/membranes16110395
UR - https://europepmc.org/article/MED/43083218
AB - Veterinary anthelmintics and neonicotinoid insecticides in aquatic environments pose challenges for conventional wastewater treatment. Six commercial ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO) membranes were evaluated for the rejection of three veterinary anthelmintics (albendazole, febantel, and mebendazole) and three neonicotinoid insecticides (acetamiprid, clothianidin, and thiacloprid). The compounds were tested individually and as a six-component mixture in demineralized and model water. After 3 h, rejection of the individual compounds was at least 92.9% with the tight NF membrane ESNA1-LF-LD and 94.1% with the RO membrane ESPA4. Neonicotinoid rejection by the UF membrane did not exceed 9.2%. In the six-component mixture, ESNA1-LF-LD rejected 87.9-94.9% of neonicotinoids and 90.1% to >99.9% of anthelmintics. The RO membranes (XLE and ESPA4) rejected 89.8-94.8% of neonicotinoids and 92.5% to >99.9% of anthelmintics. Fourier transform infrared (FTIR) spectroscopy indicated possible interactions between anthelmintics and the membranes. At the highest sample volume fraction tested, the untreated mixture caused 63.6% inhibition of Vibrio fischeri bioluminescence in demineralized water and 86.8% in model water. No inhibition was detected in the XLE or ESPA4 permeates. Rejection depended on membrane selectivity, compound properties, and water matrix. Combining chemical measurements with ecotoxicity assays provided a broader assessment of membrane treatment performance.
SN - 2077-0375
ER -