Automated Trimodal Deep Learning Fusion of MRI, CT, and Endoscopy for Preoperative Differentiation of Sinonasal Inverted Papilloma and Malignant Transformation.
- 1Department of Otolaryngology, Research Units of New Technologies of Endoscopic Surgery in Skull Base Tumor (2018RU003), Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China.
- 2ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China.
Abstract
Purpose: To develop and validate an automated trimodal deep learning fusion framework integrating magnetic resonance imaging (MRI), computed tomography (CT), and nasal endoscopy for preoperative differentiation between sinonasal inverted papilloma (SIP) and SIP-transformed squamous cell carcinoma (SIP-SCC). Materials and Methods: This retrospective study included 849 patients with pathological diagnoses of SIP (n = 614) or SIP-SCC (n = 235) between October 2014 and August 2025. Three unimodal ResNet-based deep learning models were trained and validated using data from 743 patients with only one or two modalities. The trained networks then generated MRI, CT, and endoscopy probability scores for each of 106 separate patients with complete trimodal data. These scores were combined using logistic regression, with fusion performance assessed by five-fold cross-validation in the 106-patient cohort. In the reader study, its performance was compared with six physicians (three junior, three senior). Results: The trimodal fusion model achieved an out-of-fold AUC of 0.910. Its AUC was higher than that of CT (0.634; unadjusted p < 0.001; Holm-adjusted p < 0.001) and endoscopy (0.813; unadjusted p = 0.023; Holm-adjusted p = 0.045), but the difference from MRI (0.859; unadjusted and adjusted p = 0.142) was not statistically significant. At the fixed threshold of 0.5, the fusion model achieved an accuracy of 83.0%. Accuracy differed significantly between the fusion model and the junior-reader group majority vote (64.2%; unadjusted p = 0.004; adjusted p = 0.022), but not the senior-reader group majority vote (81.1%; unadjusted p = 0.860; adjusted p = 1.000). Conclusions: By integrating MRI, CT, and endoscopy images, the trimodal fusion model achieved the highest AUC among the evaluated models for differentiating SIP from SIP-SCC, suggesting its potential value as a clinical decision support tool.
Related
- Multiphase dynamic contrast-enhanced magnetic resonance imaging radiomics nomogram for preoperative differentiation of sinonasal inverted papilloma-associated squamous cell carcinoma from benign inverted papilloma
- Vascular Patterns in Healthy and Diseased Sinonasal Mucosa: A Prospective i-Scan Image-Enhanced Endoscopy Study
- Artificial Intelligence‐Optimized Image Biomarker Identification for Sinonasal Inverted Papilloma Diagnosis Using Image‐Enhanced Versus White‐Light Endoscopy
- Surgical Success in Obstructive Sleep Apnea Patients Using Preoperative Drug‐Induced Sleep Endoscopy and Awake Endoscopy Considering Disease Severity
- Histopathological findings in laparoscopic sleeve gastrectomy specimens and their relation to preoperative endoscopy : A retrospective cross-sectional study of 954 patients
BibTeX
@article{zhao2026automated,
title = {{Automated Trimodal Deep Learning Fusion of MRI, CT, and Endoscopy for Preoperative Differentiation of Sinonasal Inverted Papilloma and Malignant Transformation.}},
author = {Xuanyu Zhao and Wentao Gong and Zhen Li and Xueli Liu and Ziqiang Chen and Yuxuan Shi and Li Wang and Wei Lv and Hongmeng Yu},
journal = {Current oncology (Toronto, Ont.)},
year = {2026},
month = nov,
doi = {10.3390/curroncol33110679},
url = {https://europepmc.org/article/MED/43082442},
note = {CC BY},
}
RIS
TY - JOUR
TI - Automated Trimodal Deep Learning Fusion of MRI, CT, and Endoscopy for Preoperative Differentiation of Sinonasal Inverted Papilloma and Malignant Transformation.
AU - Xuanyu Zhao
AU - Wentao Gong
AU - Zhen Li
AU - Xueli Liu
AU - Ziqiang Chen
AU - Yuxuan Shi
AU - Li Wang
AU - Wei Lv
AU - Hongmeng Yu
PY - 2026
DA - 2026/11/04
JO - Current oncology (Toronto, Ont.)
DO - 10.3390/curroncol33110679
UR - https://europepmc.org/article/MED/43082442
AB - Purpose: To develop and validate an automated trimodal deep learning fusion framework integrating magnetic resonance imaging (MRI), computed tomography (CT), and nasal endoscopy for preoperative differentiation between sinonasal inverted papilloma (SIP) and SIP-transformed squamous cell carcinoma (SIP-SCC). Materials and Methods: This retrospective study included 849 patients with pathological diagnoses of SIP (n = 614) or SIP-SCC (n = 235) between October 2014 and August 2025. Three unimodal ResNet-based deep learning models were trained and validated using data from 743 patients with only one or two modalities. The trained networks then generated MRI, CT, and endoscopy probability scores for each of 106 separate patients with complete trimodal data. These scores were combined using logistic regression, with fusion performance assessed by five-fold cross-validation in the 106-patient cohort. In the reader study, its performance was compared with six physicians (three junior, three senior). Results: The trimodal fusion model achieved an out-of-fold AUC of 0.910. Its AUC was higher than that of CT (0.634; unadjusted p < 0.001; Holm-adjusted p < 0.001) and endoscopy (0.813; unadjusted p = 0.023; Holm-adjusted p = 0.045), but the difference from MRI (0.859; unadjusted and adjusted p = 0.142) was not statistically significant. At the fixed threshold of 0.5, the fusion model achieved an accuracy of 83.0%. Accuracy differed significantly between the fusion model and the junior-reader group majority vote (64.2%; unadjusted p = 0.004; adjusted p = 0.022), but not the senior-reader group majority vote (81.1%; unadjusted p = 0.860; adjusted p = 1.000). Conclusions: By integrating MRI, CT, and endoscopy images, the trimodal fusion model achieved the highest AUC among the evaluated models for differentiating SIP from SIP-SCC, suggesting its potential value as a clinical decision support tool.
SN - 1198-0052
SN - 1718-7729
ER -