Stable but Not Always Correct: Large Language Model Judgments of Nurse-Assessed Symptoms and Care Problems in Rewritten Discharge Summaries.
4 affiliations
- 1School of Science, Engineering and Digital Technologies, University of Southern Queensland, 487-535 West Street, Toowoomba, QLD 4350, Australia.
- 2Yuhang Second People's Hospital, Hangzhou 311100, China.
- 3School of Business, Law, Humanities and Pathways, University of Southern Queensland, 37 Sinnathamby Boulevard, Springfield Central, QLD 4300, Australia.
- 4Faculty of Science and Technology, Danala Campus, Charles Darwin University, Darwin, NT 0909, Australia.
Abstract
Background/Objectives: Answers of large language models (LLMs) about patient records that survive rewording are often assumed reliable. We tested whether stability indicates correctness. Methods: Two open-weight LLMs released in 2024 (Llama 3.3 70B and Qwen2.5 72B, 4-bit) judged whether eight nurse-assessed symptoms and care problems were documented in 60 physician-written MIMIC-IV discharge summaries and in 522 rewrites of them intended to preserve meaning (180 rule-based, 342 LLM-generated; omissions in the LLM-generated rewrites were not checked directly). Two nurse annotations made under different versions of the definitions (κ = 0.93) formed the reference standard; the first author adjudicated disagreements. The analysis plan was not registered. Results: Both models found most documented problems (sensitivity 0.97 and 0.93) but also reported many undocumented ones (positive predictive value 0.66 and 0.76), and agreed with the nurses less than the nurses did with each other. Replacing commas with semicolons changed 2.9% and 4.4% of judgments (all rewrite types, 1.6-7.2%; rerunning identical input, 0.8%). On 442 confidently labeled items, accuracy was 84% and 89% overall, 90% and 94% for judgments that no rewrite changed, and 55% and 58% for those that changed. Yet 43-53% of wrong judgments never changed (57-63% on length-verified rewrites); the pre-specified test of whether most errors are stable was inconclusive (confidence intervals included one half). Post hoc, reviewing every positive judgment caught 84-93% of these models' errors but only 39% for a newer model (gpt-oss 120B) that mostly missed problems; no automated signal caught every error. Conclusions: In this single-site study, a judgment that changed under rewording warranted review, but a stable judgment was not necessarily correct; nurse verification remains necessary.
Related
- Large Language Models' Simulation of Patient Comprehension of Discharge Summaries: Multimodel Evaluation Study.
- Clinician Acceptance of Large Language Model–Generated Discharge Summaries
- AI-Generated Discharge Summaries—The Verification Paradox
- Gold-standard-guided direct preference optimisation for ICD-10-AM and ACHI code assignment from discharge summaries.
- Structured extraction from Russian/Kazakh discharge summaries: three model families at the human-agreement ceiling
BibTeX
@article{sun2026stable,
title = {{Stable but Not Always Correct: Large Language Model Judgments of Nurse-Assessed Symptoms and Care Problems in Rewritten Discharge Summaries.}},
author = {Yanjie Sun and Chunyan Fan and Xiaohui Tao and Xujuan Zhou and Raj Gururajan and Md Rafiqul Islam and Ji Zhang},
journal = {Nursing reports (Pavia, Italy)},
year = {2026},
month = nov,
doi = {10.3390/nursrep16110424},
url = {https://europepmc.org/article/MED/43083501},
note = {CC BY},
}
RIS
TY - JOUR
TI - Stable but Not Always Correct: Large Language Model Judgments of Nurse-Assessed Symptoms and Care Problems in Rewritten Discharge Summaries.
AU - Yanjie Sun
AU - Chunyan Fan
AU - Xiaohui Tao
AU - Xujuan Zhou
AU - Raj Gururajan
AU - Md Rafiqul Islam
AU - Ji Zhang
PY - 2026
DA - 2026/11/20
JO - Nursing reports (Pavia, Italy)
DO - 10.3390/nursrep16110424
UR - https://europepmc.org/article/MED/43083501
AB - Background/Objectives: Answers of large language models (LLMs) about patient records that survive rewording are often assumed reliable. We tested whether stability indicates correctness. Methods: Two open-weight LLMs released in 2024 (Llama 3.3 70B and Qwen2.5 72B, 4-bit) judged whether eight nurse-assessed symptoms and care problems were documented in 60 physician-written MIMIC-IV discharge summaries and in 522 rewrites of them intended to preserve meaning (180 rule-based, 342 LLM-generated; omissions in the LLM-generated rewrites were not checked directly). Two nurse annotations made under different versions of the definitions (κ = 0.93) formed the reference standard; the first author adjudicated disagreements. The analysis plan was not registered. Results: Both models found most documented problems (sensitivity 0.97 and 0.93) but also reported many undocumented ones (positive predictive value 0.66 and 0.76), and agreed with the nurses less than the nurses did with each other. Replacing commas with semicolons changed 2.9% and 4.4% of judgments (all rewrite types, 1.6-7.2%; rerunning identical input, 0.8%). On 442 confidently labeled items, accuracy was 84% and 89% overall, 90% and 94% for judgments that no rewrite changed, and 55% and 58% for those that changed. Yet 43-53% of wrong judgments never changed (57-63% on length-verified rewrites); the pre-specified test of whether most errors are stable was inconclusive (confidence intervals included one half). Post hoc, reviewing every positive judgment caught 84-93% of these models' errors but only 39% for a newer model (gpt-oss 120B) that mostly missed problems; no automated signal caught every error. Conclusions: In this single-site study, a judgment that changed under rewording warranted review, but a stable judgment was not necessarily correct; nurse verification remains necessary.
SN - 2039-439X
SN - 2039-4403
ER -