Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 54 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Medicine

Effects of Pneumoperitoneum on Mean Arterial Pressure and Hypotension Prediction Index Responses During Hemorrhage and Transfusion in a Porcine Model

  1. 1Department of Anesthesiology and Pain Medicine, Asan Medical Center, Brain Korea 21 Project, University of Ulsan College of Medicine, 88, Olympic-Ro 43-Gil, Seoul 05505, Republic of Korea
  2. 2Department of Biomedical Engineering, Asan Institute of Life Sciences, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea
  3. 3Big Data Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul 05505, Republic of Korea

Abstract

Background/Objectives: CO2 pneumoperitoneum (PnP) alters hemodynamics during laparoscopic surgery. We examined whether PnP modifies mean arterial pressure (MAP) and hypotension prediction index (HPI) responses to controlled, stepwise hemorrhage and retransfusion in a porcine model. Methods: This exploratory secondary analysis included recordings from three PnP-only pilot animals and nine animals with analyzable data from a randomized crossover experiment involving both PnP and No-PnP conditions. Blood was withdrawn and retransfused in 100 mL increments up to 600 mL per phase under both PnP (15 mmHg) and No-PnP conditions. MAP and HPI were averaged within protocol windows and analyzed using linear mixed-effects models to assess changes across protocol windows, condition-by-window interactions, and paired within-animal differences. Results: Twenty-one hemorrhage–transfusion sets from 12 animals were analyzed, comprising 12 PnP and nine No-PnP sets. MAP decreased and HPI increased overall during hemorrhage, with the opposite pattern observed during retransfusion in both conditions (all protocol-window effects, p < 0.001). No significant condition-by-window interactions were detected during hemorrhage (MAP, p = 0.407; HPI, p = 0.925) or retransfusion (MAP, p = 0.999; HPI, p = 0.910). Within-animal differences did not vary significantly across protocol windows in either phase. Conclusions: No significant PnP-related differences in the patterns of MAP and HPI change were detected in this porcine model. These findings provide experimental context for interpreting MAP and HPI during blood loss in laparoscopic surgery; clinical studies are needed to determine whether HPI adds predictive information beyond MAP.

Related

  1. Acute Profound Hypotension Following Intraoperative Plasma Transfusion—A Case Series
    Tommy Batz, Johan Nordström, Daniel Hertzberg +5
    Acta Anaesthesiologica ScandinavicaPeer-reviewedCC BY 4.0Full textGeneral medicinePMCEurope PMC
  2. Dynamic machine-learning model for early prediction of intraoperative hypotension using 5-minute perioperative time-series data: a multicenter retrospective study
    Bo Long, Yifeng Ye, Hang Xing +1
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Blood Transfusion Rates and Predictive Factors in Posterior-Based Minimally Invasive Scoliosis Surgery for Idiopathic Scoliosis: A LASSO-Based Prediction Model
    Hong Jin Kim, Dong Yun Kim, Subin Lim +3
    Global Spine JournalPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  4. Blood pressure history improves near-term hypotension prediction and reassessment prioritisation in sepsis
    L. Wang, J. Zhu, R. Zhou +14
    medRxivPreprintCC BYFull textEpidemiology & public healthmedRxiv
  5. Development and Internal Validation of a Preintubation Prediction Model for Postintubation Hypotension in Trauma Patients Undergoing Emergency Endotracheal Intubation: A Retrospective Cohort Study
    Chanatthee Kitsiripant, Komet Thongkhao, Osaree Akaraborworn +1
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossrefEurope PMC
BibTeX
@article{kim2026effects,
  title = {{Effects of Pneumoperitoneum on Mean Arterial Pressure and Hypotension Prediction Index Responses During Hemorrhage and Transfusion in a Porcine Model}},
  author = {Woo-Jin Kim and Dong-Kyu Kim and Yerin Yoon and Hyun-Seok Kim and Woo-Young Seo and Sung-Hoon Kim},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = nov,
  doi = {10.3390/jcm15218509},
  url = {https://www.mdpi.com/2077-0383/15/21/8509},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Effects of Pneumoperitoneum on Mean Arterial Pressure and Hypotension Prediction Index Responses During Hemorrhage and Transfusion in a Porcine Model
AU  - Woo-Jin Kim
AU  - Dong-Kyu Kim
AU  - Yerin Yoon
AU  - Hyun-Seok Kim
AU  - Woo-Young Seo
AU  - Sung-Hoon Kim
PY  - 2026
DA  - 2026/11/02
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15218509
UR  - https://www.mdpi.com/2077-0383/15/21/8509
AB  - Background/Objectives: CO2 pneumoperitoneum (PnP) alters hemodynamics during laparoscopic surgery. We examined whether PnP modifies mean arterial pressure (MAP) and hypotension prediction index (HPI) responses to controlled, stepwise hemorrhage and retransfusion in a porcine model. Methods: This exploratory secondary analysis included recordings from three PnP-only pilot animals and nine animals with analyzable data from a randomized crossover experiment involving both PnP and No-PnP conditions. Blood was withdrawn and retransfused in 100 mL increments up to 600 mL per phase under both PnP (15 mmHg) and No-PnP conditions. MAP and HPI were averaged within protocol windows and analyzed using linear mixed-effects models to assess changes across protocol windows, condition-by-window interactions, and paired within-animal differences. Results: Twenty-one hemorrhage–transfusion sets from 12 animals were analyzed, comprising 12 PnP and nine No-PnP sets. MAP decreased and HPI increased overall during hemorrhage, with the opposite pattern observed during retransfusion in both conditions (all protocol-window effects, p < 0.001). No significant condition-by-window interactions were detected during hemorrhage (MAP, p = 0.407; HPI, p = 0.925) or retransfusion (MAP, p = 0.999; HPI, p = 0.910). Within-animal differences did not vary significantly across protocol windows in either phase. Conclusions: No significant PnP-related differences in the patterns of MAP and HPI change were detected in this porcine model. These findings provide experimental context for interpreting MAP and HPI during blood loss in laparoscopic surgery; clinical studies are needed to determine whether HPI adds predictive information beyond MAP.
SN  - 2077-0383
ER  -