Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 2 min ago
PreprintCC BYmedRxiv

Physical calibration and signal periodic updates to synchronize IMUs for 5-day continuous knee flexion tracking

  1. 1University of Pennsylvania

Abstract

Wearable inertial measurement unit (IMU) sensors provide a promising method to assess real-world human motion kinematics. However, multi-day multi-IMU tracking is difficult due to the desynchronization driven by inaccurate IMU clocks. In this study, 15 volunteers wore IMUs continuously on their thighs and shanks for 5 weekdays (Mon-Fri), which included 3 repeated in-lab motion capture sessions. We synchronized thigh and shank IMUs using two methods. The first was physical calibration, where we maneuvered the IMUs in a rigid holder to produce sync signals pre-donning (Mon) and post-doffing (Fri), then linearly resampled data from one IMU to match the other via cross-correlation. The second was signal-based periodic updates, where we shifted IMU clocks hourly based on the timewise alignment of preprocessed body-worn acceleration signals. After syncing, we used sensor-to-segment alignment and accelerometer-gyroscope fusion to estimate knee flexion and compared results to camera-based motion capture. Physical calibration alone removed clock offset in most cases, where IMU-estimated knee flexion generally matched motion capture (correlation [≥]0.944; root-mean-square difference RMSD [≤]6.9 degrees). But in some participants, residual mid-week desynchronization (~0.2s) resulted in misestimated knee flexion (Wed: RMSD up to ~19 degrees). After applying signal-based updates or combining it with physical calibration, IMU matched motion capture on all 3 days (Mon: r [≥]0.975, RMSD [≤]6.1 degrees; Wed: r [≥]0.971, RMSD [≤]6.2 degrees, Fri: r [≥]0.977; RMSD [≤]5.9 degrees). Our multi-modal synchronization enables week-long knee flexion tracking and lays a foundation for advanced syncing tools, for improving the feasibility of wearable multi-IMU systems to continuously monitor real-world knee kinematics in clinical studies.

Related

  1. Lightweight Calibration-Based Blood Pressure Tracking from Photoplethysmography Features for Smart Devices: Accuracy, Model Size and Recalibration Interval
    Soojeong Lee, Mugahed A. Al-antari, Gangseong Lee
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Objective sleep tracking for fatigue management in cargo pilots: six months of continuous smart-ring monitoring
    N. Dhawale, A. Gade, V. Narasimhan
    medRxivPreprintCC BY-NC-NDFull textEpidemiology & public healthmedRxiv
  3. Severe Hyperglycemia due to Calibration Misuse in an Eversense-365 Implantable Continuous Glucose Monitoring System
    Jennifer Moeller
    AACE Endocrinology and DiabetesPeer-reviewedCC BY-NC-ND 4.0Full textEndocrinology & metabolismPMC
  4. Psychometric Properties and Continuous National Norms of the Parent-Report Concise Health Risk Tracking Assessment: Charting Pediatric Suicide Risk Across Age and Sex
    H. Deericks, E. A. Youngstrom, M. Westlund Schreiner
    medRxivPreprintCC BY-NCFull textPsychiatry & mental healthmedRxiv
  5. Palladium-103 brachytherapy with continuous periodic intravitreal Anti-VEGF bevacizumab for ciliary body medulloepithelioma
    Skylar L. Wingate, Paul T. Finger
    American Journal of Ophthalmology Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineDOAJPMC
BibTeX
@misc{song2026physical,
  title = {{Physical calibration and signal periodic updates to synchronize IMUs for 5-day continuous knee flexion tracking}},
  author = {K. Song and J. R. Baxter},
  howpublished = {medRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.14.26368098},
  url = {https://www.medrxiv.org/content/10.64898/2026.11.14.26368098v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Physical calibration and signal periodic updates to synchronize IMUs for 5-day continuous knee flexion tracking
AU  - K. Song
AU  - J. R. Baxter
PY  - 2026
DA  - 2026/11/14
PB  - medRxiv
DO  - 10.64898/2026.11.14.26368098
UR  - https://www.medrxiv.org/content/10.64898/2026.11.14.26368098v1
AB  - Wearable inertial measurement unit (IMU) sensors provide a promising method to assess real-world human motion kinematics. However, multi-day multi-IMU tracking is difficult due to the desynchronization driven by inaccurate IMU clocks. In this study, 15 volunteers wore IMUs continuously on their thighs and shanks for 5 weekdays (Mon-Fri), which included 3 repeated in-lab motion capture sessions. We synchronized thigh and shank IMUs using two methods. The first was physical calibration, where we maneuvered the IMUs in a rigid holder to produce sync signals pre-donning (Mon) and post-doffing (Fri), then linearly resampled data from one IMU to match the other via cross-correlation. The second was signal-based periodic updates, where we shifted IMU clocks hourly based on the timewise alignment of preprocessed body-worn acceleration signals. After syncing, we used sensor-to-segment alignment and accelerometer-gyroscope fusion to estimate knee flexion and compared results to camera-based motion capture. Physical calibration alone removed clock offset in most cases, where IMU-estimated knee flexion generally matched motion capture (correlation [≥]0.944; root-mean-square difference RMSD [≤]6.9 degrees). But in some participants, residual mid-week desynchronization (~0.2s) resulted in misestimated knee flexion (Wed: RMSD up to ~19 degrees). After applying signal-based updates or combining it with physical calibration, IMU matched motion capture on all 3 days (Mon: r [≥]0.975, RMSD [≤]6.1 degrees; Wed: r [≥]0.971, RMSD [≤]6.2 degrees, Fri: r [≥]0.977; RMSD [≤]5.9 degrees). Our multi-modal synchronization enables week-long knee flexion tracking and lays a foundation for advanced syncing tools, for improving the feasibility of wearable multi-IMU systems to continuously monitor real-world knee kinematics in clinical studies.
ER  -