Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated just now
Peer-reviewedCC BYJournal of Cachexia, Sarcopenia and Muscle

First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction

Abstract

Background Diaphragm dysfunction is an important and often unrecognized cause of dyspnea. The current gold standard, transdiaphragmatic twitch pressure (Pdi,tw), requires oesophageal and gastric balloon catheters and is infrequently used in routine care. We evaluated whether ultrafast ultrasound descriptors of costal diaphragm during bilateral phrenic magnetic stimulation can provide a noninvasive alternative for assessing diaphragm contractility. Methods Thirty patients (19 men and 11 women) referred for suspected diaphragm dysfunction (median age 57 [42–63] years) underwent bilateral anterolateral magnetic stimulation with simultaneous ultrafast ultrasound and oesophageal/gastric pressure recordings. Peak diaphragm tissue velocity, acceleration and jerk were extracted. Associations with Pdi,tw were assessed using ridge regression. Diagnostic performance for detecting abnormal Pdi,tw (< 20 cmH 2 O) was evaluated using Bayesian receiver operating characteristic (ROC) analysis, including posterior mean AUC and 95% credible intervals. Agreement between predicted and measured Pdi,tw was assessed using Lin's concordance correlation coefficient and Passing–Bablok regression. Results Twenty four of 30 patients (80%) had abnormal Pdi,tw. Ultrafast ultrasound descriptors correlated with Pdi,tw (Spearman's ρ : velocity 0.77 [95% CI, 0.57–0.89], acceleration 0.70 [95% CI, 0.41–0.87], jerk 0.67 [95% CI, 0.43–0.85]; all p < 0.0001). The multivariable ridge model explained 66% of the variance in Pdi,tw and showed high agreement with measured values (Lin's concordance correlation coefficient = 0.87 [95% CI, 0.75–0.93]). Bayesian ROC analysis demonstrated strong discrimination of diaphragm dysfunction (AUC = 0.91; 95% credible interval [CrI], 0.76–0.98). Using the clinical threshold of 20 cmH 2 O, model‐predicted Pdi,tw yielded a sensitivity of 75% and specificity of 100%. The optimal velocity threshold for discriminating abnormal Pdi,tw was 10.25 mm·ms −1 (95% CrI, 6.12–18.58 mm·ms −1 ). The corresponding thresholds for acceleration and jerk were 408.6 mm·ms −2 (95% CrI, 122.6–952.4) and 3073 mm·ms −3 (95% CrI, 1038.8–11541.4), respectively. Conclusions Ultrafast ultrasound coupled with magnetic phrenic stimulation provides a feasible, noninvasive, nonvolitional assessment of diaphragm contractility. Diaphragm motion descriptors reliably predicted Pdi,tw and enabled accurate identification of diaphragm dysfunction. These findings support further clinical evaluation and warrant larger multicentre validation studies.

Related

  1. Real-time ultrafast holography of focused ultrasound wave fields using an ultrasound scanner
    K. Matsui, F. Chavrier, T. Azuma +3
    bioRxivPreprintCC BYFull textSystems & synthetic biologybioRxiv
  2. Uncertainty Quantification in Cardiac Model Personalisation from Ultrafast Ultrasound
    Camilla Ferrario, Maelys Venet, Olivier Villemain +1
    arXivPreprintarXiv licenceFull textBioinformatics & computational biologyBiological & medical physicsarXiv
  3. Noninvasive Focal Gene Delivery of Functional Neural Actuators to the Primate Spinal Cord using Focused Ultrasound
    M. R. Corigliano, S. S. Guretse, N. T. Nosenchuck +11
    bioRxivPreprintCC BY-NCFull textNeurosciencebioRxiv
  4. Low intensity pulsed ultrasound stimulation: in-vitro experiments to study bone mechanotransduction
    Mia Brely, Lou Olive, Carine Guivier-Curien +4
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textCell biologyHAL
  5. Low intensity pulsed ultrasound stimulation of cancer cells : experimental set-up and digital twin to study mechanotransduction
    Mia Piris Patricia Brely, Youmna Guibert, Manon Carré +3
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textCell biologyHAL
BibTeX
@article{nierding2026first,
  title = {{First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction}},
  author = {Axel Nierding and Annelyse Nardi and Thomas Similowski and Christian Straus and Jean‐luc Gennisson and Damien Bachasson},
  journal = {Journal of Cachexia, Sarcopenia and Muscle},
  year = {2026},
  month = jun,
  doi = {10.1002/jcsm.70323},
  url = {https://hal.science/hal-05792961v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - First Evaluation of Ultrafast Ultrasound Coupled With Phrenic Stimulation for Noninvasive Diagnosis of Diaphragm Dysfunction
AU  - Axel Nierding
AU  - Annelyse Nardi
AU  - Thomas Similowski
AU  - Christian Straus
AU  - Jean‐luc Gennisson
AU  - Damien Bachasson
PY  - 2026
DA  - 2026/06/17
JO  - Journal of Cachexia, Sarcopenia and Muscle
DO  - 10.1002/jcsm.70323
UR  - https://hal.science/hal-05792961v1
AB  - Background Diaphragm dysfunction is an important and often unrecognized cause of dyspnea. The current gold standard, transdiaphragmatic twitch pressure (Pdi,tw), requires oesophageal and gastric balloon catheters and is infrequently used in routine care. We evaluated whether ultrafast ultrasound descriptors of costal diaphragm during bilateral phrenic magnetic stimulation can provide a noninvasive alternative for assessing diaphragm contractility. Methods Thirty patients (19 men and 11 women) referred for suspected diaphragm dysfunction (median age 57 [42–63] years) underwent bilateral anterolateral magnetic stimulation with simultaneous ultrafast ultrasound and oesophageal/gastric pressure recordings. Peak diaphragm tissue velocity, acceleration and jerk were extracted. Associations with Pdi,tw were assessed using ridge regression. Diagnostic performance for detecting abnormal Pdi,tw (< 20 cmH 2 O) was evaluated using Bayesian receiver operating characteristic (ROC) analysis, including posterior mean AUC and 95% credible intervals. Agreement between predicted and measured Pdi,tw was assessed using Lin's concordance correlation coefficient and Passing–Bablok regression. Results Twenty four of 30 patients (80%) had abnormal Pdi,tw. Ultrafast ultrasound descriptors correlated with Pdi,tw (Spearman's ρ : velocity 0.77 [95% CI, 0.57–0.89], acceleration 0.70 [95% CI, 0.41–0.87], jerk 0.67 [95% CI, 0.43–0.85]; all p < 0.0001). The multivariable ridge model explained 66% of the variance in Pdi,tw and showed high agreement with measured values (Lin's concordance correlation coefficient = 0.87 [95% CI, 0.75–0.93]). Bayesian ROC analysis demonstrated strong discrimination of diaphragm dysfunction (AUC = 0.91; 95% credible interval [CrI], 0.76–0.98). Using the clinical threshold of 20 cmH 2 O, model‐predicted Pdi,tw yielded a sensitivity of 75% and specificity of 100%. The optimal velocity threshold for discriminating abnormal Pdi,tw was 10.25 mm·ms −1 (95% CrI, 6.12–18.58 mm·ms −1 ). The corresponding thresholds for acceleration and jerk were 408.6 mm·ms −2 (95% CrI, 122.6–952.4) and 3073 mm·ms −3 (95% CrI, 1038.8–11541.4), respectively. Conclusions Ultrafast ultrasound coupled with magnetic phrenic stimulation provides a feasible, noninvasive, nonvolitional assessment of diaphragm contractility. Diaphragm motion descriptors reliably predicted Pdi,tw and enabled accurate identification of diaphragm dysfunction. These findings support further clinical evaluation and warrant larger multicentre validation studies.
SN  - 2190-5991
SN  - 2190-6009
ER  -