Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BY 4.0Frontiers in Neurology

SAMSeeK: nervous centralis lesion diagnostic report generation via SAM 2 and vision-language models

5 affiliations
  1. 1Medical School, Tianjin University
  2. 2The First Affiliated Hospital of Hebei North University
  3. 3Graduate School of Tianjin Medical University
  4. 4College of Computer Science and Artificial Intelligence, Fudan University
  5. 5Department of Hepatobiliary and Pancreatic Surgery I, General Surgery Center, The First Hospital of Jilin University

Abstract

Objective: This study investigates the capability of visual language models (VLMs) in generating accurate diagnostic reports for neurological disorders of the central nervous system. To address the critical challenge of background-induced misclassification, we propose a novel framework that enables joint lesion segmentation, quantitative analysis, and report generation—thereby improving the reliability and clinical relevance of automated brain lesion diagnosis.

Methods: We present SAMSeeK , a unified model that integrates a geometry-aware vision encoder with a large VLM. To overcome the limitations of conventional sequential modeling in capturing spatially heterogeneous brain lesions, we incorporate Hilbert curve-guided scanning into the Mamba architecture and redesign both the encoder and decoder of SAM 2 to enhance local-global contextual awareness of lesion regions. Furthermore, we introduce a structured prompt enhancement mechanism that injects quantitative lesion attributes—such as volume, spatial coordinates, and pixel-level extent—into Qwen 2.5-VL to ground report generation in anatomically precise information. The model is trained and evaluated on a curated dataset of 4,800 2D brain MRI slices spanning three major pathologies: glioma, epilepsy (including focal cortical dysplasia), and cerebral infarction, and validated across three public benchmarks (BraTS2021, FCD2023, ISLES2022).

Results: SAMSeeK achieves state-of-the-art performance in both segmentation and classification. It attains an average Dice coefficient of 82.4% and IoU of 73.5% on BraTS2021, outperforming existing methods by a significant margin. In lesion-type classification, it reaches 81.2% accuracy , 83.6% precision , 83.9% recall , and an F1-score of 0.852 . Leveraging these capabilities, SAMSeeK successfully generated 4,800 clinically plausible diagnostic reports, each enriched with quantitative lesion descriptors.

Conclusion: By synergizing Hilbert-enhanced spatial modeling with VLM-driven semantic reasoning, SAMSeeK effectively mitigates background interference and significantly improves lesion localization and classification accuracy. The framework demonstrates strong potential as a reliable tool for automated, interpretable, and quantitative brain lesion report generation in clinical neuroimaging workflows.

Related

  1. Central nervous system efficacy of third generation vs. first generation EGFR-TKIs in the first line treatment for EGFR-mutated non-small cell lung cancer with central nervous system metastases: a systematic review and meta-analysis of phase 3 randomized controlled trials
    Jiongli Gan, Shaofeng Zhu, Yan Fang +3
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. 1023 Next-Generation Sequencing in Pediatric Central Nervous System Tumors: Molecular Yield and Clinical Impact from a National Precision Oncology Program in Uruguay
    Neuro-oncology advancesPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  3. EP10.37 Pediatric nervous system tumors in Armenia : diagnostic discrepancies and time to diagnosis in an institutional cohort
    A Asminian, J Hoveyan, S Bardakhchyan +2
    Neuro-OncologyPeer-reviewedPublisher termsFull textOncologyPMC
  4. Cerebrospinal fluid lipidome in central nervous system infections: a study of diagnostic accuracy
    Steven L. Staal, Sabine E. Olie, Jan-Bert van Klinken +19
    eBioMedicinePeer-reviewedCC BY 4.0General medicineCrossref
  5. Copy‐Number Alterations in Central Nervous System Tumours: Diagnostic and Prognostic Implications
    Christian Thomas
    Neuropathology and Applied NeurobiologyPeer-reviewedCC BY 4.0Full textOncologyPMC
BibTeX
@article{tian2026samseek,
  title = {{SAMSeeK: nervous centralis lesion diagnostic report generation via SAM 2 and vision-language models}},
  author = {Ye Tian and Lu Wang and Yahui Kang and Xinming Yang and Chaowei Yang and Xingzhu Xu and Bi Xue and Shuxuan Li},
  journal = {Frontiers in Neurology},
  year = {2026},
  month = nov,
  doi = {10.3389/fneur.2026.1979682},
  url = {https://www.frontiersin.org/articles/10.3389/fneur.2026.1979682/full},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - SAMSeeK: nervous centralis lesion diagnostic report generation via SAM 2 and vision-language models
AU  - Ye Tian
AU  - Lu Wang
AU  - Yahui Kang
AU  - Xinming Yang
AU  - Chaowei Yang
AU  - Xingzhu Xu
AU  - Bi Xue
AU  - Shuxuan Li
PY  - 2026
DA  - 2026/11/26
JO  - Frontiers in Neurology
DO  - 10.3389/fneur.2026.1979682
UR  - https://www.frontiersin.org/articles/10.3389/fneur.2026.1979682/full
AB  - Objective: This study investigates the capability of visual language models (VLMs) in generating accurate diagnostic reports for neurological disorders of the central nervous system. To address the critical challenge of background-induced misclassification, we propose a novel framework that enables joint lesion segmentation, quantitative analysis, and report generation—thereby improving the reliability and clinical relevance of automated brain lesion diagnosis.  Methods: We present SAMSeeK , a unified model that integrates a geometry-aware vision encoder with a large VLM. To overcome the limitations of conventional sequential modeling in capturing spatially heterogeneous brain lesions, we incorporate Hilbert curve-guided scanning into the Mamba architecture and redesign both the encoder and decoder of SAM 2 to enhance local-global contextual awareness of lesion regions. Furthermore, we introduce a structured prompt enhancement mechanism that injects quantitative lesion attributes—such as volume, spatial coordinates, and pixel-level extent—into Qwen 2.5-VL to ground report generation in anatomically precise information. The model is trained and evaluated on a curated dataset of 4,800 2D brain MRI slices spanning three major pathologies: glioma, epilepsy (including focal cortical dysplasia), and cerebral infarction, and validated across three public benchmarks (BraTS2021, FCD2023, ISLES2022).  Results: SAMSeeK achieves state-of-the-art performance in both segmentation and classification. It attains an average Dice coefficient of 82.4% and IoU of 73.5% on BraTS2021, outperforming existing methods by a significant margin. In lesion-type classification, it reaches 81.2% accuracy , 83.6% precision , 83.9% recall , and an F1-score of 0.852 . Leveraging these capabilities, SAMSeeK successfully generated 4,800 clinically plausible diagnostic reports, each enriched with quantitative lesion descriptors.  Conclusion: By synergizing Hilbert-enhanced spatial modeling with VLM-driven semantic reasoning, SAMSeeK effectively mitigates background interference and significantly improves lesion localization and classification accuracy. The framework demonstrates strong potential as a reliable tool for automated, interpretable, and quantitative brain lesion report generation in clinical neuroimaging workflows.
SN  - 1664-2295
ER  -