Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 23 min ago
Peer-reviewedCC BY-NCBMJ connections. Surgery

Prospective case series of an articulated laparoscopic camera system in minimally invasive surgery in gynaecology: an IDEAL stage 2a study.

  1. 1Gleneagles Hospital Hong Kong, Hong Kong, Hong Kong.
  2. 2Department of Obstetrics and Gynaecology, The University of Hong Kong, Hong Kong, Hong Kong.
  3. 3Precision Robotics (Hong Kong) Limited, Hong Kong, Hong Kong.

Abstract

Objectives

Precision Robotics' Sirius Robotic Flexible Endoscopic System is a new fully integrated compact laparoscopic camera system with a disposable single-use flexible tip that can change its viewing direction. The aim of this Idea, Development, Exploration, Assessment, Long-term follow-up stage 2a study was to assess its clinical performance and safety.Design

Prospective multi-institution, multisurgeon study.Setting

The study was conducted in two multispecialty hospitals.Participants

Women aged 18-70 years scheduled for gynaecological laparoscopic surgery were invited to participate. An information sheet and consent form were available for the women and an informed consent was obtained. Twenty-five participants completed this study.Interventions

The laparoscopic procedures were done in the usual manner. The only difference was the Sirius system was used in place of the usual conventional laparoscope. All other procedures and instruments including the number of ports used remained the same.Main outcome measures

Primary outcome was camera users and surgeon's view and experience; iterations and modifications to the system. Secondary outcomes were the incidence of intraoperative and postoperative complications during the first 6 weeks following surgery and duration of surgery.Results

100% (25/25) of women had their procedure completed successfully using the Sirius System. There were no intraoperative complications. The median operating time was 68 min (range: 32-257 min). Users agreed that the improved field of view was beneficial for laparoscopic surgery. Iterative improvements were made in the user interface and manufacturing quality.Conclusions

The study demonstrated stability and safety of the Sirius System across different institutions and teams for intermediate and major minimally invasive laparoscopic procedures in gynaecology. Further studies are needed to confirm it can replace a conventional laparoscope in the surgical workflow.Trial registration

NCT05048407.

Related

  1. Postoperative C-Reactive Protein as a Marker of the Early Inflammatory Response in Robotic Versus Laparoscopic Minimally Invasive Surgery for Endometrial Cancer: A Propensity Score-Matched Analysis
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Minimally invasive management of pediatric hereditary spherocytosis: severity-stratified biliary risk and indications for simultaneous cholecystectomy and biliary intervention at laparoscopic splenectomy – a single-center retrospective study
    Radek Ambrož, Petr Birke, Jiří Kysučan +7
    BMC PediatricsPeer-reviewedCC BYFull textHuman geneticsDOAJ
  3. Prospective validation of multimodal risk stratification using clinical and quantitative imaging features for 12-month outcomes after minimally invasive surgery for lumbar disc herniation
    Jichong Zhu, Hao Li, Chunxian Lu +8
    Frontiers in artificial intelligencePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  4. Bench Testing of an 8 N Slip Resistance Specification for the Handle Shaft Locking Interface of an Articulated Laparoscopic Instrument
    H. Ma
    medRxivPreprintCC BY-NC-NDFull textSurgery & anaesthesiamedRxiv
  5. Transaxillary valve surgery: innovation through simplicity in minimally invasive cardiac surgery
    Annals of Cardiothoracic SurgeryPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{ng2026prospective,
  title = {{Prospective case series of an articulated laparoscopic camera system in minimally invasive surgery in gynaecology: an IDEAL stage 2a study.}},
  author = {Tong Yow Ng and Siew Fei Ngu and Sai Yan Ng and Ping Lai Benny Lo},
  journal = {BMJ connections. Surgery},
  year = {2026},
  month = jul,
  doi = {10.1136/bmjcsurg-2026-000024},
  url = {https://europepmc.org/article/MED/42968910},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Prospective case series of an articulated laparoscopic camera system in minimally invasive surgery in gynaecology: an IDEAL stage 2a study.
AU  - Tong Yow Ng
AU  - Siew Fei Ngu
AU  - Sai Yan Ng
AU  - Ping Lai Benny Lo
PY  - 2026
DA  - 2026/07/01
JO  - BMJ connections. Surgery
DO  - 10.1136/bmjcsurg-2026-000024
UR  - https://europepmc.org/article/MED/42968910
AB  - Objectives  Precision Robotics' Sirius Robotic Flexible Endoscopic System is a new fully integrated compact laparoscopic camera system with a disposable single-use flexible tip that can change its viewing direction. The aim of this Idea, Development, Exploration, Assessment, Long-term follow-up stage 2a study was to assess its clinical performance and safety.Design  Prospective multi-institution, multisurgeon study.Setting  The study was conducted in two multispecialty hospitals.Participants  Women aged 18-70 years scheduled for gynaecological laparoscopic surgery were invited to participate. An information sheet and consent form were available for the women and an informed consent was obtained. Twenty-five participants completed this study.Interventions  The laparoscopic procedures were done in the usual manner. The only difference was the Sirius system was used in place of the usual conventional laparoscope. All other procedures and instruments including the number of ports used remained the same.Main outcome measures  Primary outcome was camera users and surgeon's view and experience; iterations and modifications to the system. Secondary outcomes were the incidence of intraoperative and postoperative complications during the first 6 weeks following surgery and duration of surgery.Results  100% (25/25) of women had their procedure completed successfully using the Sirius System. There were no intraoperative complications. The median operating time was 68 min (range: 32-257 min). Users agreed that the improved field of view was beneficial for laparoscopic surgery. Iterative improvements were made in the user interface and manufacturing quality.Conclusions  The study demonstrated stability and safety of the Sirius System across different institutions and teams for intermediate and major minimally invasive laparoscopic procedures in gynaecology. Further studies are needed to confirm it can replace a conventional laparoscope in the surgical workflow.Trial registration  NCT05048407.
SN  - 2978-1809
ER  -