Unintentional Intra-Implant Fat Injection During Breast Fat Grafting
- 1Department of Surgery, Division of Plastic and Reconstructive Surgery, Emory University School of Medicine, Atlanta, GA
- 2Morehouse School of Medicine, Atlanta, GA
Abstract
Background:: Fat grafting is commonly used in implant-based breast reconstruction to improve contour and soft-tissue quality. Cannula-related implant injury during fat grafting is considered rare and is infrequently discussed in the literature.
Methods:: A focused review of PubMed and Embase identified reports describing implant puncture or rupture associated with fat grafting. In addition, we present an institutional case of delayed implant infection following fat grafting, with intraoperative identification of intraprosthetic fat.
Results:: Four published case reports and a case discussion within a retrospective review of fat grafting patients describe cannula-induced implant puncture with intraprosthetic fat deposition, presenting variably with pain, capsular contracture, shape change, or infection. Larger series report low but non-zero rates of implant injury following fat grafting. Our case involved a radiated breast with delayed infection 18 months after fat grafting; explantation revealed multiple implant punctures and intraprosthetic fat without free silicone extrusion.
Conclusions:: Cannula-related implant injury during fat grafting is an uncommon but likely underrecognized complication with heterogeneous presentation and limited detectability on imaging. Awareness and adherence to protective techniques are essential to minimize risk.
Related
- Early recognition and safe management of unintentional intrathecal placement of an epidural catheter during combined spinal-epidural labor analgesia: a case report in the context of the 2024 OAA guidelines.
- Does parathyroid autofluorescence reduces unintentional parathyroidectomy during total thyroidectomy with central lymph node compartment dissection?
- Bilateral breast implant-associated anaplastic large cell lymphoma presenting as late peri-implant effusion: a case report
- Long-term oncological outcomes after nipple-sparing mastectomy and implant-based immediate breast reconstruction in a population-based cohort of breast cancer patients
- Breast implant-associated late hematoma: a narrative review of case reports and case series
BibTeX
@article{smearman2026unintentional,
title = {{Unintentional Intra-Implant Fat Injection During Breast Fat Grafting}},
author = {Erica Smearman and Melissa Issa-Boube and Grant W. Carlson},
journal = {Annals of Plastic Surgery},
year = {2026},
month = aug,
doi = {10.1097/sap.0000000000004845},
url = {https://doi.org/10.1097/sap.0000000000004845},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Unintentional Intra-Implant Fat Injection During Breast Fat Grafting
AU - Erica Smearman
AU - Melissa Issa-Boube
AU - Grant W. Carlson
PY - 2026
DA - 2026/08/05
JO - Annals of Plastic Surgery
DO - 10.1097/sap.0000000000004845
UR - https://doi.org/10.1097/sap.0000000000004845
AB - Background:: Fat grafting is commonly used in implant-based breast reconstruction to improve contour and soft-tissue quality. Cannula-related implant injury during fat grafting is considered rare and is infrequently discussed in the literature. Methods:: A focused review of PubMed and Embase identified reports describing implant puncture or rupture associated with fat grafting. In addition, we present an institutional case of delayed implant infection following fat grafting, with intraoperative identification of intraprosthetic fat. Results:: Four published case reports and a case discussion within a retrospective review of fat grafting patients describe cannula-induced implant puncture with intraprosthetic fat deposition, presenting variably with pain, capsular contracture, shape change, or infection. Larger series report low but non-zero rates of implant injury following fat grafting. Our case involved a radiated breast with delayed infection 18 months after fat grafting; explantation revealed multiple implant punctures and intraprosthetic fat without free silicone extrusion. Conclusions:: Cannula-related implant injury during fat grafting is an uncommon but likely underrecognized complication with heterogeneous presentation and limited detectability on imaging. Awareness and adherence to protective techniques are essential to minimize risk.
SN - 0148-7043
SN - 1536-3708
ER -