Skip to content
DraconiticResearch
Search Sources API
210,049 studies31 sourcesUpdated 22 min ago
Peer-reviewedCC BY 4.0The British and Irish Orthoptic Journal

Evaluating Slit-Lamp Performance in Diagnosing Anterior Uveitis: A Simulated Model Approach – Are All Slit-Lamps the Same, and Does it Matter?

  1. 1University of Sheffield, UK
  2. 2Sheffield Teaching Hospitals NHS Foundation Trust : Sheffield, South Yorkshire, UK
  3. 3Sheffield Children’s NHS Foundation Trust, UK

Abstract

Background/Objectives:: Anterior uveitis is diagnosed by detecting inflammatory cells in the anterior chamber using slit lamp biomicroscopy. Available slit lamps can vary significantly in illumination quality, potentially affecting diagnostic accuracy. This study evaluates device-to-device variability in slit lamp illumination within a tertiary ophthalmic centre and assesses its impact on anterior uveitis detection.

Subjects/Methods:: 43 Haag-Streit BQ900 slit lamps (21 tungsten, 22 LED) were evaluated. Lux emissions were quantified using a calibrated photometer under standardised conditions. Simulated anterior chambers were developed using particles (~15 μm diameter) suspended in ethanol, targeting cell concentrations according to Standardisation of Uveitis Nomenclature (SUN) criteria grades 0–4+. Thirteen masked observers graded each chamber under standardised settings, comparing the dimmest tungsten and LED lamps. Statistical analyses included coefficient of variation (CV), independent and paired t-tests and Bland-Altman.

Results:: All slit lamps demonstrated variability in lux output, even among identical models. LED slit lamps exhibited a markedly higher maximum brightness (some >200,000 lux) than tungsten models (max 126,400 lux). Under diagnostic conditions (1 × 1 mm beam, 45°), LED slit lamps emitted significantly higher and more consistent lux compared to tungsten lamps (LED mean: 1275 ± 503 lux; tungsten mean: 793 ± 438 lux; p = 0.0017). In anterior chamber simulations, LED illumination improved detection at lower SUN grades (0.5+: LED mean = 2.23 cells, tungsten = 0.77 cells, p = 0.00006; 1+: LED = 5.77, tungsten = 4.15, p = 0.0403).

Conclusions:: Slit lamp illumination varies substantially. In a simulated model, lower illuminance was associated with reduced detection of low-grade inflammation. Routine illumination auditing and equipment standardisation, considering the broader adoption of LED slit lamps, may improve the reliability of uveitis assessment.

Related

  1. Anterior Uveitis in Patients With Methylenetetrahydrofolate Reductase (MTHFR) Gene Polymorphisms: A Case Series
    Nancy Zakaria, Caroline A Tawfik, Samir Shoughy
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  2. P007 Delayed-Onset Acute Anterior Uveitis Associated with Long-Term Zoledronic Acid Therapy in Metastatic Prostate Cancer
    Khin Swe Win, Khaled Mahmoud, Khizer Iqbal +1
    Rheumatology advances in practicePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  3. Performance of ultra-sensitive electrochemiluminescence LAM assay for diagnosing tuberculosis in HIV-negative individuals: a multicentre, prospective diagnostic study
    Yuanyuan Shang, Jiachang Zhang, Wenli Cao +11
    InfectionPeer-reviewedCC BY-NC-ND 4.0Full text1 citedInfectious diseasePMC
  4. Effects of Probiotic Supplementation on Performance Retention During Detraining and Recovery After Simulated Return-to-Training Stress in College Volleyball Players: An Exploratory Randomized, Single-Blind, Placebo-Controlled Trial
    Jin Liu, Kai Zhao, Chenzhe Liu +2
    NutrientsPeer-reviewedCC BYFull textNutritionEurope PMC
  5. Effects of video reinforcement following face-to-face CPR/AED training on knowledge, attitude, and simulated performance among frontline community workers: a quasi-experimental study with post-training randomized allocation
    Farzaneh Mirzaei, Ali Nasiri, Abbas Abbaszadeh +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0General medicineCrossref
BibTeX
@article{ma2026evaluating,
  title = {{Evaluating Slit-Lamp Performance in Diagnosing Anterior Uveitis: A Simulated Model Approach – Are All Slit-Lamps the Same, and Does it Matter?}},
  author = {Kwok Kit Johnny Ma and Martin Rhodes and Joe Baxter and Thomas Evans and Jessy Choi},
  journal = {The British and Irish Orthoptic Journal},
  year = {2026},
  month = nov,
  doi = {10.22599/bioj.577},
  url = {https://doi.org/10.22599/bioj.577},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Evaluating Slit-Lamp Performance in Diagnosing Anterior Uveitis: A Simulated Model Approach – Are All Slit-Lamps the Same, and Does it Matter?
AU  - Kwok Kit Johnny Ma
AU  - Martin Rhodes
AU  - Joe Baxter
AU  - Thomas Evans
AU  - Jessy Choi
PY  - 2026
DA  - 2026/11/04
JO  - The British and Irish Orthoptic Journal
DO  - 10.22599/bioj.577
UR  - https://doi.org/10.22599/bioj.577
AB  - Background/Objectives:: Anterior uveitis is diagnosed by detecting inflammatory cells in the anterior chamber using slit lamp biomicroscopy. Available slit lamps can vary significantly in illumination quality, potentially affecting diagnostic accuracy. This study evaluates device-to-device variability in slit lamp illumination within a tertiary ophthalmic centre and assesses its impact on anterior uveitis detection.  Subjects/Methods:: 43 Haag-Streit BQ900 slit lamps (21 tungsten, 22 LED) were evaluated. Lux emissions were quantified using a calibrated photometer under standardised conditions. Simulated anterior chambers were developed using particles (~15 μm diameter) suspended in ethanol, targeting cell concentrations according to Standardisation of Uveitis Nomenclature (SUN) criteria grades 0–4+. Thirteen masked observers graded each chamber under standardised settings, comparing the dimmest tungsten and LED lamps. Statistical analyses included coefficient of variation (CV), independent and paired t-tests and Bland-Altman.  Results:: All slit lamps demonstrated variability in lux output, even among identical models. LED slit lamps exhibited a markedly higher maximum brightness (some >200,000 lux) than tungsten models (max 126,400 lux). Under diagnostic conditions (1 × 1 mm beam, 45°), LED slit lamps emitted significantly higher and more consistent lux compared to tungsten lamps (LED mean: 1275 ± 503 lux; tungsten mean: 793 ± 438 lux; p = 0.0017). In anterior chamber simulations, LED illumination improved detection at lower SUN grades (0.5+: LED mean = 2.23 cells, tungsten = 0.77 cells, p = 0.00006; 1+: LED = 5.77, tungsten = 4.15, p = 0.0403).  Conclusions:: Slit lamp illumination varies substantially. In a simulated model, lower illuminance was associated with reduced detection of low-grade inflammation. Routine illumination auditing and equipment standardisation, considering the broader adoption of LED slit lamps, may improve the reliability of uveitis assessment.
SN  - 1743-9868
SN  - 2516-3590
ER  -