Peer-reviewedCC BY-NC-ND 4.0Journal of the Society for Cardiovascular Angiography & Interventions
Mitral Transcatheter Edge-to-Edge Repair in a Challenging Anatomy With Deeply Implanted Self-Expanding Valve and Severe Mitral Annular Calcification: A Case Report
- 1The Carl and Edyth Lindner Research Center at The Christ Hospital, Cincinnati, Ohio
Abstract
Mitral transcatheter edge-to-edge repair (M-TEER) in the setting of prior transcatheter aortic valve replacement (TAVR) and severe mitral annular calcification (MAC) can pose procedural challenges. We describe the case of an 82-year-old woman with prior TAVR (29 mm EVOLUT FX+; Medtronic), P2 flail, and heavy circumferential MAC underwent M-TEER with the PASCAL Ace device (Edwards Lifesciences). This case illustrates that M-TEER can be performed safely and effectively in anatomies complicated by severe MAC and prior TAVR with careful preprocedural planning, intraprocedural imaging, and operator experience.
Related
- Feasibility of steerable sheath-guided left atrial appendage closure in challenging anatomy
- Transcatheter Aortic Valve Implantation in Complex Anatomy: An Anatomy-Driven Framework for Bicuspid Stenosis, Pure Aortic Regurgitation, and the Small Annulus in the Era of Lifetime Management
- Asymmetry of Transcatheter Aortic Valves: Is Anatomy Destiny?
- Modified balloon-assisted shoehorn technique for transcatheter aortic valve implantation in functionally horizontal anatomy: a case report
- Surgical aortic valve replacement-level aortotomy for self-expanding transcatheter aortic valve explantation
BibTeX
@article{saad2026mitral,
title = {{Mitral Transcatheter Edge-to-Edge Repair in a Challenging Anatomy With Deeply Implanted Self-Expanding Valve and Severe Mitral Annular Calcification: A Case Report}},
author = {Muhammad Saad and Raviteja Guddeti and Nadia El-Hangouche and Santiago Garcia},
journal = {Journal of the Society for Cardiovascular Angiography \& Interventions},
year = {2026},
month = aug,
doi = {10.1016/j.jscai.2026.105571},
url = {https://doi.org/10.1016/j.jscai.2026.105571},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Mitral Transcatheter Edge-to-Edge Repair in a Challenging Anatomy With Deeply Implanted Self-Expanding Valve and Severe Mitral Annular Calcification: A Case Report
AU - Muhammad Saad
AU - Raviteja Guddeti
AU - Nadia El-Hangouche
AU - Santiago Garcia
PY - 2026
DA - 2026/08/13
JO - Journal of the Society for Cardiovascular Angiography & Interventions
DO - 10.1016/j.jscai.2026.105571
UR - https://doi.org/10.1016/j.jscai.2026.105571
AB - Mitral transcatheter edge-to-edge repair (M-TEER) in the setting of prior transcatheter aortic valve replacement (TAVR) and severe mitral annular calcification (MAC) can pose procedural challenges. We describe the case of an 82-year-old woman with prior TAVR (29 mm EVOLUT FX+; Medtronic), P2 flail, and heavy circumferential MAC underwent M-TEER with the PASCAL Ace device (Edwards Lifesciences). This case illustrates that M-TEER can be performed safely and effectively in anatomies complicated by severe MAC and prior TAVR with careful preprocedural planning, intraprocedural imaging, and operator experience.
SN - 2772-9303
ER -