Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 53 min ago
PreprintCC BY 4.0arXiv

PANDA-D: Interface-free determination of two dynamic contact angles

Abstract

Contact angles are central descriptors of wetting and capillary behavior at solid--fluid interfaces. Dynamic contact angles in molecular simulations are commonly extracted from two-dimensional liquid--vapor contours and near-wall tangent fits. We introduce PANDA-D, an extension of Predicting Angle from Nanoscale Density Analysis (PANDA) that determines both contact angles of a driven liquid roll without extracting an interface. The density profile measures occupied layer width but does not identify which meniscus is advancing. The method resolves this ambiguity by jointly fitting density and the layerwise center-of-mass displacement relative to the roll. A circular-meniscus model maps these profiles to receding and advancing angles and an effective near-wall offset. On synthetic rolls with prescribed angles, the reconstruction error is 0.29∘ root-mean-square. We then analyze force-driven Lennard--Jones rolls between crystalline walls. Joint fits reproduce both measured profiles, whereas density-only fits can match density while assigning incorrect asymmetry. The resulting angles agree with independently determined circle-fit angles to 0.84∘ root-mean-square. Across four wall--fluid attractions, the receding angle decreases and the advancing angle increases with force, approximately linearly over the studied ranges. By eliminating contour thresholds and near-wall tangent extrapolation from the primary estimate, the two-profile approach enables reproducible, automated angle analysis across molecular trajectories.

Related

  1. Migrating cell clusters as active droplets with asymmetric shape and contact angles
    Hanno I. Hennighausen, Jaime A. Espina, Elias H. Barriga +1
    arXivPreprintarXiv licenceFull textBiological & medical physicsCondensed matterarXiv
  2. Osseointegration dynamics at bone-implant interface: contact and distant osteogenesis
    Corinne Mahfouz, Elsa Vennat, Sophie Le Cann
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  3. Contact-free charge carrier density determination of doped sub-μm thin cubic GaN layers with terahertz time-domain spectroscopy
    Joshua Hennig, Mario F. Zscherp, Silas A. Jentsch +11
    arXivPreprintCC BY 4.0Full textOptics & photonicsarXiv
  4. Fast analytical models for the non-linear scattering of elastic waves at a contact interface
    Michel Darmon, Zakaria Yajioui
    Acta AcusticaPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  5. Effect of metal/semiconductor interface on the resistance of a nonalloyed p-GaN/Ni–Au contact
    Jules Duraz, Hassen Souissi, Maksym Gromovyi +13
    Journal of Vacuum Science & Technology B Microelectronics and Nanometer StructuresPeer-reviewedCC BY-NC 4.0Full textCondensed matterHAL
BibTeX
@misc{vandyshev2026pandad,
  title = {{PANDA-D: Interface-free determination of two dynamic contact angles}},
  author = {Georgii K. Vandyshev and Grigorii S. Gorkaev and Nikolay D. Kondratyuk and Kirill M. Gerke and Ilia V. Kopanichuk},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.21996},
  eprint = {2610.21996},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.21996},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - PANDA-D: Interface-free determination of two dynamic contact angles
AU  - Georgii K. Vandyshev
AU  - Grigorii S. Gorkaev
AU  - Nikolay D. Kondratyuk
AU  - Kirill M. Gerke
AU  - Ilia V. Kopanichuk
PY  - 2026
DA  - 2026/10/15
PB  - arXiv
DO  - 10.48550/arxiv.2610.21996
UR  - https://arxiv.org/abs/2610.21996
AB  - Contact angles are central descriptors of wetting and capillary behavior at solid--fluid interfaces. Dynamic contact angles in molecular simulations are commonly extracted from two-dimensional liquid--vapor contours and near-wall tangent fits. We introduce PANDA-D, an extension of Predicting Angle from Nanoscale Density Analysis (PANDA) that determines both contact angles of a driven liquid roll without extracting an interface. The density profile measures occupied layer width but does not identify which meniscus is advancing. The method resolves this ambiguity by jointly fitting density and the layerwise center-of-mass displacement relative to the roll. A circular-meniscus model maps these profiles to receding and advancing angles and an effective near-wall offset. On synthetic rolls with prescribed angles, the reconstruction error is 0.29^∘ root-mean-square. We then analyze force-driven Lennard--Jones rolls between crystalline walls. Joint fits reproduce both measured profiles, whereas density-only fits can match density while assigning incorrect asymmetry. The resulting angles agree with independently determined circle-fit angles to 0.84^∘ root-mean-square. Across four wall--fluid attractions, the receding angle decreases and the advancing angle increases with force, approximately linearly over the studied ranges. By eliminating contour thresholds and near-wall tangent extrapolation from the primary estimate, the two-profile approach enables reproducible, automated angle analysis across molecular trajectories.
ER  -