Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 48 min ago
Peer-reviewedCC BY 4.0Nanophotonics

A Ranging System Integrating Time‐of‐Flight Approach With Optical‐Frequency‐Comb Interferometry for Ultra‐Precise Long‐Distance Measurements

5 affiliations
  1. 1Shanghai Key Laboratory of Modern Optical System, Engineering Research Center of Optical Instrument and System (Ministry of Education) School of Optical‐Electrical and Computer Engineering University of Shanghai for Science and Technology Shanghai China
  2. 2Institute of Advanced Precision Spectroscopy of East China Normal University Shanghai China
  3. 3National Key Laboratory of Electromagnetic Space Security Tianjin China
  4. 4National Key Laboratory of Science and Technology on Space Microwave China Academy of Space Technology Xi’An China
  5. 5School of Computer Science and Information Engineering Shanghai Institute of Technology Shanghai China

Abstract

Time‐of‐flight (TOF) ranging and pulse interference have been widely applied in high‐precision absolute ranging due to high robustness and low ambient noises. However, TOF is typically limited by low resolutions, whereas the absolute lengths determined using the pulse interference method are discrete. In this study, an absolute ranging system integrating TOF with OFC‐based interferometric modules was developed. In this system, the TOF module provides a rapid yet rough distance measurement, whereas the Michelson interferometry module significantly improves the ranging accuracy using interference techniques. First, the approximate distance was estimated using the TOF laser rangefinder. Then, the spatial position information of femtosecond pulse interference signals was determined through OFC‐based interferometric measurement. Finally, the exact distance was determined based on the rough measurement and the fine measurement. Sub‐meter simulations and practical measurements revealed that the t‐distribution‐based limit error were ± 1.3 and ± 2 μm within 50 m, respectively, demonstrating that the proposed ranging system integrating pulse coarse with OFC achieved a micron‐level absolute distance accuracy for 10‐m‐scale measurement tasks. The proposed system can be further optimized in terms of active frequency stabilization, extended TOF range, and full‐wave sampling and processing. This study paves the way for effective long‐distance ranging with ultra‐high precision requirements.

Related

  1. Multi-synthetic-wavelength fusion-enhanced multi-heterodyne interferometry for high-precision absolute distance measurement
    Jiandong Xie, Xinyang Zhao, Jian Wang +2
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  2. Vibration-resistant temporal phase-shifting interferometry with enhanced amplitude–frequency product tolerance
    Fengrui Li, Zhigang Han, Jiarui Xu +1
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  3. Two-Tone Tomography: Phase sensitive characterization of a coherent frequency conversion device by spectral interferometry
    Mateusz Olszewski, Kasper Alexander, Michael Woodley +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Unlimited-Range Absolute Distance Interferometry Outdoors via Tunable Synthetic and Pseudo-Supersynthetic Wavelengths: The TeleYAG-II Interferometer
    Florian Pollinger, Tobias Meyer, Frank Pilarski +6
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationOptics & photonicsarXiv
  5. Sensitivity Comparison of Microwave-Frequency and Optical Fibre Interferometry Based on State-of-the-Art Components
    Georgios Aias Karydis, Marco Fasano, Paola Parolari +3
    arXivPreprintCC BY 4.0Full textOptics & photonicsarXiv
BibTeX
@article{yang2026ranging,
  title = {{A Ranging System Integrating Time‐of‐Flight Approach With Optical‐Frequency‐Comb Interferometry for Ultra‐Precise Long‐Distance Measurements}},
  author = {Cunliang Yang and Xiao Wang and Zihao Zhang and Junhao Li and Jingjing Wang and Jinman Ge and Lizhong Xiao and Jijun Feng},
  journal = {Nanophotonics},
  year = {2026},
  month = nov,
  doi = {10.1002/nap2.70343},
  url = {https://doi.org/10.1002/nap2.70343},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - A Ranging System Integrating Time‐of‐Flight Approach With Optical‐Frequency‐Comb Interferometry for Ultra‐Precise Long‐Distance Measurements
AU  - Cunliang Yang
AU  - Xiao Wang
AU  - Zihao Zhang
AU  - Junhao Li
AU  - Jingjing Wang
AU  - Jinman Ge
AU  - Lizhong Xiao
AU  - Jijun Feng
PY  - 2026
DA  - 2026/11/11
JO  - Nanophotonics
DO  - 10.1002/nap2.70343
UR  - https://doi.org/10.1002/nap2.70343
AB  - Time‐of‐flight (TOF) ranging and pulse interference have been widely applied in high‐precision absolute ranging due to high robustness and low ambient noises. However, TOF is typically limited by low resolutions, whereas the absolute lengths determined using the pulse interference method are discrete. In this study, an absolute ranging system integrating TOF with OFC‐based interferometric modules was developed. In this system, the TOF module provides a rapid yet rough distance measurement, whereas the Michelson interferometry module significantly improves the ranging accuracy using interference techniques. First, the approximate distance was estimated using the TOF laser rangefinder. Then, the spatial position information of femtosecond pulse interference signals was determined through OFC‐based interferometric measurement. Finally, the exact distance was determined based on the rough measurement and the fine measurement. Sub‐meter simulations and practical measurements revealed that the t‐distribution‐based limit error were ± 1.3 and ± 2 μm within 50 m, respectively, demonstrating that the proposed ranging system integrating pulse coarse with OFC achieved a micron‐level absolute distance accuracy for 10‐m‐scale measurement tasks. The proposed system can be further optimized in terms of active frequency stabilization, extended TOF range, and full‐wave sampling and processing. This study paves the way for effective long‐distance ranging with ultra‐high precision requirements.
SN  - 2192-8614
ER  -