Skip to content
DraconiticResearch
Search Sources API
197,688 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BY 4.0Frontiers in Cardiovascular Medicine

Balancing innovation and safety in percutaneous treatment of coronary artery calcification: the evolving role of cutting balloon technology

6 affiliations
  1. 1Department of Cardiology, CHU Dupuytren
  2. 2Department of Cardiology, Hôpital de Jolimont, Hélora Network
  3. 3Department of Cardiology, Hôpital d'Arlon
  4. 4Department of Cardiology, Centre Hospitalier de Wallonie picarde (CHwapi)
  5. 5Department of Cardiology, University Hospital Basel
  6. 6Department of Cardiology, CHU Saint-Étienne

Abstract

Background: Cutting balloon (CB) angioplasty is one of several approaches to lesion preparation in calcified coronary artery disease. Its comparative efficacy, safety, and optimal use remain incompletely defined.

Aims: To critically appraise clinical studies and emerging technical concepts concerning CB angioplasty, with particular attention to evidence strength, patient selection, and safety.

Methods: This narrative review discusses selected randomised trials, observational studies, mechanistic investigations, and emerging reports concerning CB-based lesion preparation.

Findings: Randomised studies have reported improvements in selected acute imaging endpoints, but findings differ across populations and treatment strategies. Observational studies suggest progressive lumen gain during sequential CB inflations; however, these observations do not establish an optimal inflation protocol. Evidence for comparative long-term clinical benefit and rare device-related complications remains limited. Reported procedural cost differences should not be equated with generalisable cost-effectiveness. Inflation above the device's rated burst pressure constitutes off-label use and falls outside the manufacturer's recommended pressure limits. The Index of Device Efficiency (IDE) remains an exploratory metric rather than a validated treatment target.

Conclusion: CB may be considered among complementary calcium-modification options in appropriately selected lesions. Device choice should reflect anatomy, crossability, imaging findings, and patient risk. Current evidence does not justify routine high-pressure iterative CB use beyond device labelling or universal IDE-guided treatment targets.

Related

  1. Balancing innovation and safety in percutaneous treatment of coronary artery calcification
    Ayman Helal, Andrew Ladwiniec, Abdul Mozid +10
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossrefDOAJ
  2. Balancing innovation and ethics: responsible governance of artificial intelligence hallucinations in healthcare.
    Meixin Du, Ni Zhan
    Philosophy, ethics, and humanities in medicine : PEHMPeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthEurope PMCPMCDOAJ
  3. Editorial: Comprehensive approaches to multivalvular disease: diagnosis, treatment, and innovation
    Alon Shechter, Anastasios Apostolos
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Full textCardiovascular medicineCrossref
  4. Percutaneous treatment of iatrogenic left main coronary artery aneurysm with a covered stent
    Aleksandra Gąsecka, Martyna Świerkowska, Piotr Arski +2
    Cardiology JournalPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  5. Effects of percutaneous kyphoplasty with concomitant postural reduction in the treatment of acute osteoporotic vertebral compression fractures
    Yulin Chen, Peng Yang, Ankejiang Anniwaer +4
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{chenard2026balancing,
  title = {{Balancing innovation and safety in percutaneous treatment of coronary artery calcification: the evolving role of cutting balloon technology}},
  author = {Pierre Chenard and Claudiu Ungureanu and Giuseppe Colletti and Adrien Jossart and Daciana Popa and Agostino Spano and Gregor Leibundgut and Marouane Boukhris},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  month = nov,
  doi = {10.3389/fcvm.2026.1968355},
  url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.1968355/full},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Balancing innovation and safety in percutaneous treatment of coronary artery calcification: the evolving role of cutting balloon technology
AU  - Pierre Chenard
AU  - Claudiu Ungureanu
AU  - Giuseppe Colletti
AU  - Adrien Jossart
AU  - Daciana Popa
AU  - Agostino Spano
AU  - Gregor Leibundgut
AU  - Marouane Boukhris
PY  - 2026
DA  - 2026/11/05
JO  - Frontiers in Cardiovascular Medicine
DO  - 10.3389/fcvm.2026.1968355
UR  - https://www.frontiersin.org/articles/10.3389/fcvm.2026.1968355/full
AB  - Background: Cutting balloon (CB) angioplasty is one of several approaches to lesion preparation in calcified coronary artery disease. Its comparative efficacy, safety, and optimal use remain incompletely defined.  Aims: To critically appraise clinical studies and emerging technical concepts concerning CB angioplasty, with particular attention to evidence strength, patient selection, and safety.  Methods: This narrative review discusses selected randomised trials, observational studies, mechanistic investigations, and emerging reports concerning CB-based lesion preparation.  Findings: Randomised studies have reported improvements in selected acute imaging endpoints, but findings differ across populations and treatment strategies. Observational studies suggest progressive lumen gain during sequential CB inflations; however, these observations do not establish an optimal inflation protocol. Evidence for comparative long-term clinical benefit and rare device-related complications remains limited. Reported procedural cost differences should not be equated with generalisable cost-effectiveness. Inflation above the device's rated burst pressure constitutes off-label use and falls outside the manufacturer's recommended pressure limits. The Index of Device Efficiency (IDE) remains an exploratory metric rather than a validated treatment target.  Conclusion: CB may be considered among complementary calcium-modification options in appropriately selected lesions. Device choice should reflect anatomy, crossability, imaging findings, and patient risk. Current evidence does not justify routine high-pressure iterative CB use beyond device labelling or universal IDE-guided treatment targets.
SN  - 2297-055X
ER  -