Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 43 min ago
PreprintCC BY 4.0arXiv

PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping

5 more authors

Abstract

Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.

Related

  1. INI-VPINN: A Variational Physics-Informed Neural Network with Implicit Neumann and Interface Handling for Multi-Material Domains with Geometric Singularities
    Shayan Dodge, Alessandro Formisano, Sami Barmada
    arXivPreprintarXiv licenceFull textNumerical analysis & scientific computingComputational physicsarXiv
  2. Physics-informed, boundary-constrained Gaussian process regression for the reconstruction of fluid flow fields
    Adrian Padilla-Segarra, Pascal Noble, Olivier Roustant +1
    International Journal for Uncertainty QuantificationPeer-reviewedLicence not statedFull text2 citedStatistical & nonlinear physicsHAL
  3. Reconstruction and Synthesis of Arbitrary Optical Intensity Patterns in Extremely Multimode Waveguide Cavities via Physics-Informed Optimized Modal Superposition
    Javad Babaki, Hadi Ahmadi, Sanchita Sarker +2
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. A Physics-Informed, PIV-Based Method for Surface Pressure Reconstruction
    Abbas Daliri, Fulvio Scarano
    arXivPreprintCC BY-SA 4.0Full textFluid dynamicsarXiv
  5. Reconstruction of Magnetic Fields with a Physics-Informed Neural Network
    P. Adhikari, R. Bhattarai, J. Brewington +9
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
BibTeX
@misc{bulut2026primesvr,
  title = {{PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping}},
  author = {Busra Bulut and Maik Dannecker and Thomas Sanchez and Sara Neves Silva and Steven Jia and Jean-Baptiste Ledoux and Leo Pomar and Joanna Sichitiu and Yvan Gomez and Meriam Koob and Vincent Dunet and Maria Deprez and Guillaume Auzias and Francois Rousseau and Jana Hutter and Daniel Rueckert and Meritxell Bach Cuadra},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2607.20136},
  eprint = {2607.20136},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2607.20136},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - PRIME-SVR: Physics-infoRmed Implicit Multi-Echo Slice-to-Volume Reconstruction for Fetal T2 mapping
AU  - Busra Bulut
AU  - Maik Dannecker
AU  - Thomas Sanchez
AU  - Sara Neves Silva
AU  - Steven Jia
AU  - Jean-Baptiste Ledoux
AU  - Leo Pomar
AU  - Joanna Sichitiu
AU  - Yvan Gomez
AU  - Meriam Koob
AU  - Vincent Dunet
AU  - Maria Deprez
AU  - Guillaume Auzias
AU  - Francois Rousseau
AU  - Jana Hutter
AU  - Daniel Rueckert
AU  - Meritxell Bach Cuadra
PY  - 2026
DA  - 2026/09/09
PB  - arXiv
DO  - 10.48550/arxiv.2607.20136
UR  - https://arxiv.org/abs/2607.20136
AB  - Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations. Existing SVR methods are optimized and validated only for clinical-range echo times (TEs), limiting their use at non-clinical TEs and making them incompatible with quantitative T2 mapping, a protocol- and center-independent biomarker of fetal brain maturation requiring HR reconstructions across multiple TEs. We present PRIME-SVR, the first implicit neural representation (INR) framework for joint HR reconstruction from multi-echo MRI. A single fully connected network models a continuous function from spatial coordinates to signal intensities across TEs, while a second network estimates slice-specific acquisition degradations. Cross-TE coherence is enforced via a Bloch equation-derived regularization penalizing deviations from expected T2 decay, with adaptive weighting that strengthens coupling for degraded stacks. The method is fully self-supervised. We validate PRIME-SVR on 39 in vivo fetal acquisitions (13 subjects x 3 TEs) from two centers, two vendors, and two field strengths (1.5 T and 0.55 T). Compared to state-of-the-art SVR, PRIME-SVR improves reconstruction sharpness by 47%, anatomical accuracy by 30%, and cross-TE structural consistency by 14%. It enables reconstruction at late TEs previously inaccessible to SVR, yielding the first 0.8 mm isotropic T2 maps at 0.55 T and the first T2 maps derived from INR-based SVR. PRIME-SVR also accelerates quantitative imaging by reducing the data needed for multi-TE reconstruction, cutting acquisition from 15 to 10 minutes while keeping T2 accuracy within 1.7% in white and deep gray matter, or to 5 minutes with a mean T2 error of 2.3% for high-quality acquisitions.
ER  -