Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 20 min ago
PreprintCC BY-NC-ND 4.0arXiv

Characterization and Mitigation of Boundary Sampling Artifacts in Electron Phase Space Generation for Clinical FLASH-RT Deployment

Abstract

Applicator-specific phase space (PHSP) files recorded at the aperture exit reduce Monte Carlo dose calculation time by 30-50% for electron FLASH radiotherapy. However, positioning PHSP scoring planes coincident with the applicator-air interface introduces boundary sampling artifacts. This study characterizes these artifacts in Geant4-based simulations and demonstrates their mitigation. PHSP files were generated using GAMOS 6.2.0 for a 9 MeV Mobetron UHDR model across twelve clinical aperture configurations (2.5-10 cm diameter). Three scoring plane positions were evaluated relative to the physical aperture exit: coincident with the interface, 0.1 mm downstream, and 1 mm downstream. Scoring at the exact interface produced proximal R50 shifts of up to 2.2 mm and Distance-to-Agreement (DTA) values of 4-6 mm, exceeding clinical acceptance criteria. Artifact severity scaled inversely with aperture diameter, with the smallest configurations most severely affected. A 0.1 mm offset partially restored the primary electron energy spectrum but failed to recover the bremsstrahlung tail. A 1 mm offset fully resolved all artifacts, achieving mean DTA values within 2.0 mm, equivalent to or better than linac-exit references. These artifacts arise from the degenerate behavior of the fUseSafety step-limitation algorithm when safety equals zero at exact material boundaries, producing incomplete secondary electron equilibration and suppressed bremsstrahlung production. Angular distribution analysis revealed a near-forward particle pileup in the 0 mm PHSP and a deficit of large-angle secondaries recovered by the 1 mm offset. A 1 mm downstream offset fully mitigates these artifacts while introducing negligible perturbation to primary beam characteristics. This requirement applies to any Geant4-based framework (including TOPAS and GATE) scoring PHSP files at material exit surfaces.

Related

  1. Foreground Characterization and Mitigation in the Observations of the CD/EoR with the SKA
    Philip Bull, Jacob Burba, Emilio Ceccotti +20
    HALPreprintLicence not statedGeneral astronomyApplied physics & instrumentationHAL
  2. When Error Mitigation Makes Things Worse: Budget-Aware Evaluation, Extrapolation Failure, and the Calibration Trust Boundary
    Guilin Zhang, Kai Zhao, Xiquan Cui +3
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  3. Parasitic Interference in Heterodyne Interferometers: Modeling, Characterization, and Mitigation
    Pengzhuo Wang, Jose Sanjuan, Moritz Mehmet +1
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
  4. Numerical modelling of the poto-poto by coupling of finite elements and boundary elements for acoustic characterization
    E. Kowa Ketchadji, U.J. Pettang Nana, Joël Ducourneau +3
    Results in engineeringPeer-reviewedCC BY-NC-ND 4.0Full text6 citedGeneral physicsHAL
  5. Characterization of YAl₃(BO₃)₄ nonlinear properties for second harmonic generation in the green and UV ranges
    Florent Cassouret, Helinand Robin, Yoichi Sato +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
BibTeX
@misc{carballeira2026characterization,
  title = {{Characterization and Mitigation of Boundary Sampling Artifacts in Electron Phase Space Generation for Clinical FLASH-RT Deployment}},
  author = {Rafael Carballeira and Rongxiao Zhang and Kevin J. Willy and Hayley Cash and David J. Gladstone},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2605.02605},
  eprint = {2605.02605},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2605.02605},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - UNPB
TI  - Characterization and Mitigation of Boundary Sampling Artifacts in Electron Phase Space Generation for Clinical FLASH-RT Deployment
AU  - Rafael Carballeira
AU  - Rongxiao Zhang
AU  - Kevin J. Willy
AU  - Hayley Cash
AU  - David J. Gladstone
PY  - 2026
DA  - 2026/09/24
PB  - arXiv
DO  - 10.48550/arxiv.2605.02605
UR  - https://arxiv.org/abs/2605.02605
AB  - Applicator-specific phase space (PHSP) files recorded at the aperture exit reduce Monte Carlo dose calculation time by 30-50% for electron FLASH radiotherapy. However, positioning PHSP scoring planes coincident with the applicator-air interface introduces boundary sampling artifacts. This study characterizes these artifacts in Geant4-based simulations and demonstrates their mitigation. PHSP files were generated using GAMOS 6.2.0 for a 9 MeV Mobetron UHDR model across twelve clinical aperture configurations (2.5-10 cm diameter). Three scoring plane positions were evaluated relative to the physical aperture exit: coincident with the interface, 0.1 mm downstream, and 1 mm downstream. Scoring at the exact interface produced proximal R50 shifts of up to 2.2 mm and Distance-to-Agreement (DTA) values of 4-6 mm, exceeding clinical acceptance criteria. Artifact severity scaled inversely with aperture diameter, with the smallest configurations most severely affected. A 0.1 mm offset partially restored the primary electron energy spectrum but failed to recover the bremsstrahlung tail. A 1 mm offset fully resolved all artifacts, achieving mean DTA values within 2.0 mm, equivalent to or better than linac-exit references. These artifacts arise from the degenerate behavior of the fUseSafety step-limitation algorithm when safety equals zero at exact material boundaries, producing incomplete secondary electron equilibration and suppressed bremsstrahlung production. Angular distribution analysis revealed a near-forward particle pileup in the 0 mm PHSP and a deficit of large-angle secondaries recovered by the 1 mm offset. A 1 mm downstream offset fully mitigates these artifacts while introducing negligible perturbation to primary beam characteristics. This requirement applies to any Geant4-based framework (including TOPAS and GATE) scoring PHSP files at material exit surfaces.
ER  -