Skip to content
DraconiticResearch
Search Sources API
226,742 studies31 sourcesUpdated 52 min ago
Peer-reviewedCC BYFrontiers in medicine

A study on the diagnostic value of ultrasound combined with serum MK and TSP-1 in diagnosing placental abruption.

  1. 1Affiliated Hospital of Shandong Academy of Traditional Chinese Medicine, Jinan, Shandong, China.
  2. 2Shandong Provincial Maternal and Child Health Care Hospital Affiliated to Qingdao University, Jinan, Shandong, China.

Abstract

Objective

To explore the clinical value of combined detection of Midkine (MK) and thrombospondin-1 (TSP-1) in serum with ultrasound in the diagnosis of placental abruption.Methods

A total of 138 pregnant women with suspected placental abruption during antenatal check-ups at Shandong Provincial Maternal and Child Health Care Hospital Affiliated to Qingdao University from July 2022 to July 2025 were enrolled. They were divided into a placental abruption group (n = 88) and a non-placental abruption group (n = 50) based on whether placental abruption occurred. Both groups underwent ultrasound examination and serum MK and TSP-1 level testing. The serum MK and TSP-1 levels, ultrasound findings, and pregnancy outcomes were compared between the two groups. A combined diagnostic model was constructed using binary logistic regression in R software, and internal validation was performed using bootstrap optimism correction with 500 resamples. The combined diagnostic model performance was evaluated by ROC curve analysis, calibration curves, and decision curve analysis.Results

Serum MK and TSP-1 levels were significantly higher in the placental abruption group than in the non-abruption group (P < 0.05). Ultrasound findings in the placental abruption group were significantly more prevalent than in the non-abruption group (P < 0.05). The combined diagnostic method showed higher sensitivity, accuracy, and Youden's index than ultrasound or serum MK/TSP-1 alone, and its AUC was significantly higher than that of each individual marker (P < 0.05). After bootstrap internal validation, the optimism-corrected AUC was 0.809, and the calibration error (mean absolute error) was 0.09 indicating good model performance. Pregnancy outcomes were significantly poorer in the placental abruption group.Conclusion

Ultrasound combined with serum MK and TSP-1 testing may offer potential as an adjunctive diagnostic tool to aid in the evaluation of clinically suspected placental abruption compared to single-marker approaches in this exploratory retrospective cohort.

Related

  1. Diagnostic accuracy of computed tomography alone versus computed tomography combined with ultrasound for diagnosing lymph node metastasis in thyroid cancer
    Hussain A. Alharbi, MBBS, Laila Z. Alzamil, MBBS, Sumaiya H. Muathen, SBORL, FACS +4
    Journal of Taibah University Medical SciencesPeer-reviewedCC BYFull textEndocrinology & metabolismDOAJ
  2. Extensive Placental Abruption With Fetal Demise and Couvelaire Uterus in an Adolescent in a Low-Resource Setting: A Case Report
    Myung S Choi, Charlotte R Laidler, Katherine H Gonzalez Valladares +2
    CureusPeer-reviewedCC BY 4.0Full textEpidemiology & public healthObstetrics, gynaecology & paediatricsPMC
  3. Acute-on-chronic placental abruption complicated by prolonged oligohydramnios and life-threatening hemorrhagic shock: a case report
    Zain Eddin Alhawari, Dema Adwan
    International Journal of Surgery Case ReportsPeer-reviewedCC BY 4.0Full textObstetrics, gynaecology & paediatricsPMCEurope PMC
  4. Diagnostic value of C-reactive protein-to-lymphocyte ratio combined with ultrasound features for complicated appendicitis: a retrospective cohort study
    Bixia Lin, Junfan Chen, Weide Lin +1
    BMC GastroenterologyPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  5. Incremental diagnostic value of serum progesterone combined with transvaginal ultrasound in differentiating early ectopic pregnancy: a single-center real-world study
    Leilei Liu, Yao Cai, Tingting Wang
    Frontiers in medicinePeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
BibTeX
@article{cui2026study,
  title = {{A study on the diagnostic value of ultrasound combined with serum MK and TSP-1 in diagnosing placental abruption.}},
  author = {Yanfei Cui and Houmei Han},
  journal = {Frontiers in medicine},
  year = {2026},
  month = oct,
  doi = {10.3389/fmed.2026.1906391},
  url = {https://europepmc.org/article/MED/43011103},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - A study on the diagnostic value of ultrasound combined with serum MK and TSP-1 in diagnosing placental abruption.
AU  - Yanfei Cui
AU  - Houmei Han
PY  - 2026
DA  - 2026/10/27
JO  - Frontiers in medicine
DO  - 10.3389/fmed.2026.1906391
UR  - https://europepmc.org/article/MED/43011103
AB  - Objective  To explore the clinical value of combined detection of Midkine (MK) and thrombospondin-1 (TSP-1) in serum with ultrasound in the diagnosis of placental abruption.Methods  A total of 138 pregnant women with suspected placental abruption during antenatal check-ups at Shandong Provincial Maternal and Child Health Care Hospital Affiliated to Qingdao University from July 2022 to July 2025 were enrolled. They were divided into a placental abruption group (n = 88) and a non-placental abruption group (n = 50) based on whether placental abruption occurred. Both groups underwent ultrasound examination and serum MK and TSP-1 level testing. The serum MK and TSP-1 levels, ultrasound findings, and pregnancy outcomes were compared between the two groups. A combined diagnostic model was constructed using binary logistic regression in R software, and internal validation was performed using bootstrap optimism correction with 500 resamples. The combined diagnostic model performance was evaluated by ROC curve analysis, calibration curves, and decision curve analysis.Results  Serum MK and TSP-1 levels were significantly higher in the placental abruption group than in the non-abruption group (P < 0.05). Ultrasound findings in the placental abruption group were significantly more prevalent than in the non-abruption group (P < 0.05). The combined diagnostic method showed higher sensitivity, accuracy, and Youden's index than ultrasound or serum MK/TSP-1 alone, and its AUC was significantly higher than that of each individual marker (P < 0.05). After bootstrap internal validation, the optimism-corrected AUC was 0.809, and the calibration error (mean absolute error) was 0.09 indicating good model performance. Pregnancy outcomes were significantly poorer in the placental abruption group.Conclusion  Ultrasound combined with serum MK and TSP-1 testing may offer potential as an adjunctive diagnostic tool to aid in the evaluation of clinically suspected placental abruption compared to single-marker approaches in this exploratory retrospective cohort.
SN  - 2296-858X
ER  -