Peer-reviewedCC BY 4.0Frontiers in Cardiovascular Medicine
Case Report: Steerable catheter- and balloon-assisted recapture of a self-expanding pulmonary valve: a novel technical solution
- 1Pediatric Cardiology, Bambino Gesù Children's Hospital, IRCCS
- 2Pediatric Cardiology Department, Onassis Hospital
Abstract
A 24-year-old female patient, with tetralogy of Fallot corrected with a transannular patch as an infant, presented with severe pulmonary valve regurgitation and right ventricle dilatation. A transcatheter pulmonary valve replacement was decided upon with a self-expanding Harmony valve. During the implantation, the valve jumped lower than expected in the main pulmonary artery and recapture was therefore attempted. A steerable catheter and a balloon were used to realign the valve and recapture it in the DrySeal sheath.
Related
- Epidural Adhesiolysis and Dorsal Root Ganglion Pulsed Radiofrequency Through a Single Multifunctional Catheter: A Narrative Review and Illustrated Technical Report
- Lumbar Access Catheter-Assisted Epidural Blood Patch for Extensive Cerebrospinal Fluid Leakage in Spontaneous Intracranial Hypotension: A Technical Note with Postprocedural CT Evaluation.
- A case of unintentional superior vena cava isolation during pulmonary vein isolation using a lattice-tip catheter.
- Transition From Continuous Intravenous to Inhaled Treprostinil: A Case of Refractory Pulmonary Arterial Hypertension With Catheter-related Infection
- Grid annotation vs ablation tags in predicting lesion area coverage for pulmonary vein isolation using a variable-loop circular catheter.
BibTeX
@article{chatziantoniou2026case,
title = {{Case Report: Steerable catheter- and balloon-assisted recapture of a self-expanding pulmonary valve: a novel technical solution}},
author = {Anastasios Chatziantoniou and Enrico Piccinelli and Micol Rebonato and Mara Pilati and Gianfranco Butera},
journal = {Frontiers in Cardiovascular Medicine},
year = {2026},
month = nov,
doi = {10.3389/fcvm.2026.1993353},
url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.1993353/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Case Report: Steerable catheter- and balloon-assisted recapture of a self-expanding pulmonary valve: a novel technical solution
AU - Anastasios Chatziantoniou
AU - Enrico Piccinelli
AU - Micol Rebonato
AU - Mara Pilati
AU - Gianfranco Butera
PY - 2026
DA - 2026/11/26
JO - Frontiers in Cardiovascular Medicine
DO - 10.3389/fcvm.2026.1993353
UR - https://www.frontiersin.org/articles/10.3389/fcvm.2026.1993353/full
AB - A 24-year-old female patient, with tetralogy of Fallot corrected with a transannular patch as an infant, presented with severe pulmonary valve regurgitation and right ventricle dilatation. A transcatheter pulmonary valve replacement was decided upon with a self-expanding Harmony valve. During the implantation, the valve jumped lower than expected in the main pulmonary artery and recapture was therefore attempted. A steerable catheter and a balloon were used to realign the valve and recapture it in the DrySeal sheath.
SN - 2297-055X
ER -