Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 52 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Medicine

Sustaining High-Dose Hemodiafiltration in Routine Clinical Practice: A Retrospective Evaluation of a Quality Improvement Intervention

  1. 1Department of Nephrology, Ziv Medical Center, Safed P.O. Box 1008, Israel
  2. 2Department of Otolaryngology, Ziv Medical Center, Safed P.O. Box 1008, Israel
  3. 3The Azrieli Faculty of Medicine, Bar-Ilan University, Safed P.O. Box 1589, Israel

Abstract

Background: High-volume post-dilution online hemodiafiltration (HDF) may improve clinical outcomes, but consistent delivery of the required convective dose remains difficult in routine practice. We evaluated whether a structured, multistep quality improvement intervention could increase and sustain the proportion of treatments achieving a convection volume of at least 23 L per session. Methods: This single-center retrospective study included 54 adults receiving maintenance post-dilution online HDF between January 2021 and December 2024. Three periods were examined: pre-intervention (T0; January 2021–June 2023), implementation (T1; July–December 2023), and maintenance (T2; January–December 2024). The intervention addressed blood flow, vascular access practices, access recirculation, anticoagulation, access dysfunction, and staff education. Repeated measures were compared using the Friedman test. Multivariable linear regression and linear mixed-effects models assessed factors associated with target achievement. Results: Median target achievement of high-volume HDF was 39.7% (17.9–66.2) during the pre-intervention period (T0), 41.4% (16.1–72.2) during implementation (T1), and 81.9% (70.4–95.0) during maintenance (T2) (p < 0.001). Prescribed blood flow increased from 291 mL/min at T0 to 307 mL/min at T1 and 373 mL/min at T2 (p < 0.001), while effective Kt/V increased from 1.2 at T0 and T1 to 1.4 at T2 (p < 0.001). Median interdialytic weight gain remained stable. At the treatment-session level, target achievement among AVF/AVG sessions was 44.6% at T0, 44.8% at T1, and 82.5% at T2; corresponding values among tunneled-catheter sessions were 38.2%, 45.2%, and 75.5%, respectively. Treatment duration showed a statistically significant but clinically small difference across periods, without sustained prolongation. In the mixed-effects models, higher blood flow was independently associated with target achievement (B = 0.342 per mL/min; 95% CI 0.268–0.415; p < 0.001). Conclusions: A structured quality improvement program was associated with a large and sustained increase in high-volume HDF delivery. The improvement coincided principally with higher blood flow and better dialysis adequacy rather than longer treatment time. These findings support a standardized, multistep intervention for sustaining high-volume HDF in a real-world environment without increasing the time burden of treatments. Controlled multicenter studies are needed to confirm generalizability, safety, and sustainability over time.

Related

  1. Impact of a Continuous Quality Improvement Committee on Outcomes for Patients Undergoing Percutaneous Coronary Intervention: A Single-Center Retrospective Cohort Study
    Arnav Kumar Singla, Basmah Fayaz, Christopher Heinrich +9
    Journal of the Society for Cardiovascular Angiography & InterventionsPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMCEurope PMC
  2. Virtual reality as a non-pharmacological intervention for pediatric preoperative anxiety: A quality improvement initiative and retrospective analysis
    Walaa S. Abu Rukbah, Narendra Vadlamudi, Siri Garrett +2
    PLOS Digital HealthPeer-reviewedCC BY 4.0Full textCardiovascular medicineObstetrics, gynaecology & paediatricsPLOS
  3. Comparative Evaluation of Hemodiafiltration, Hemoperfusion, and Standard Hemodialysis on Efficacy, Inflammatory Control, Dialysis Adequacy, and Safety in End‐Stage Renal Disease: A Prospective Observational Study
    Hongwei Zuo, Weisi Dai, Jie Mao +3
    Therapeutic Apheresis and DialysisPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  4. Pre-Existing Mood Disorder is Associated with Higher Odds of Withdrawal of Life-Sustaining Treatment (WOLST) After Severe Stroke: A Retrospective Cohort Study
    C. McHugh, C. M. Kabongo, M. Siegel +1
    medRxivPreprintAll rights reservedFull textNeurologymedRxiv
  5. The Impact of a Neurocollaborative Theraplay®-Informed Intervention on the Presentations of Developmental Trauma and Attachment Difficulties in a Sub-Group of Autistic Looked after Children: a Retrospective Service Evaluation
    Jack Purrington, Gemma Hartley, Alan Price +4
    Journal of Child & Adolescent TraumaPeer-reviewedCC BY 4.0Full textPsychiatry & mental healthPMC
BibTeX
@article{bathish2026sustaining,
  title = {{Sustaining High-Dose Hemodiafiltration in Routine Clinical Practice: A Retrospective Evaluation of a Quality Improvement Intervention}},
  author = {Younes Bathish and Louisa Rostom and Elite Elkobi and Alaa Safia},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = nov,
  doi = {10.3390/jcm15239158},
  url = {https://www.mdpi.com/2077-0383/15/23/9158},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Sustaining High-Dose Hemodiafiltration in Routine Clinical Practice: A Retrospective Evaluation of a Quality Improvement Intervention
AU  - Younes Bathish
AU  - Louisa Rostom
AU  - Elite Elkobi
AU  - Alaa Safia
PY  - 2026
DA  - 2026/11/22
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15239158
UR  - https://www.mdpi.com/2077-0383/15/23/9158
AB  - Background: High-volume post-dilution online hemodiafiltration (HDF) may improve clinical outcomes, but consistent delivery of the required convective dose remains difficult in routine practice. We evaluated whether a structured, multistep quality improvement intervention could increase and sustain the proportion of treatments achieving a convection volume of at least 23 L per session. Methods: This single-center retrospective study included 54 adults receiving maintenance post-dilution online HDF between January 2021 and December 2024. Three periods were examined: pre-intervention (T0; January 2021–June 2023), implementation (T1; July–December 2023), and maintenance (T2; January–December 2024). The intervention addressed blood flow, vascular access practices, access recirculation, anticoagulation, access dysfunction, and staff education. Repeated measures were compared using the Friedman test. Multivariable linear regression and linear mixed-effects models assessed factors associated with target achievement. Results: Median target achievement of high-volume HDF was 39.7% (17.9–66.2) during the pre-intervention period (T0), 41.4% (16.1–72.2) during implementation (T1), and 81.9% (70.4–95.0) during maintenance (T2) (p < 0.001). Prescribed blood flow increased from 291 mL/min at T0 to 307 mL/min at T1 and 373 mL/min at T2 (p < 0.001), while effective Kt/V increased from 1.2 at T0 and T1 to 1.4 at T2 (p < 0.001). Median interdialytic weight gain remained stable. At the treatment-session level, target achievement among AVF/AVG sessions was 44.6% at T0, 44.8% at T1, and 82.5% at T2; corresponding values among tunneled-catheter sessions were 38.2%, 45.2%, and 75.5%, respectively. Treatment duration showed a statistically significant but clinically small difference across periods, without sustained prolongation. In the mixed-effects models, higher blood flow was independently associated with target achievement (B = 0.342 per mL/min; 95% CI 0.268–0.415; p < 0.001). Conclusions: A structured quality improvement program was associated with a large and sustained increase in high-volume HDF delivery. The improvement coincided principally with higher blood flow and better dialysis adequacy rather than longer treatment time. These findings support a standardized, multistep intervention for sustaining high-volume HDF in a real-world environment without increasing the time burden of treatments. Controlled multicenter studies are needed to confirm generalizability, safety, and sustainability over time.
SN  - 2077-0383
ER  -