Skip to content
DraconiticResearch
Search Sources API
201,818 studies31 sourcesUpdated 20 min ago
PreprintCC BY 4.0arXiv

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

Abstract

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 μm-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 μs transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

Related

  1. High-resolution in situ analysis of biomass pyrolysis by combining quantitative synchrotron μCT and 3D particle-resolved simulations
    Emeric Boigné, Mohamed M. Ahmed, Collin Foster +7
    arXivPreprintCC BY-NC-ND 4.0Full textPhysical chemistryApplied physics & instrumentationarXiv
  2. Beamstop-free small-angle X-ray scattering for multiscale structure measurement of high-energy-density plasma
    Masato Ota, Ryutaro Matsui, Melanie Rodel +44
    Communications PhysicsPeer-reviewedCC BY-NC-ND 4.0Full textHigh-energy & particle physicsCrossref
  3. Momentum-resolved thermodynamics and barrier-free order-parameter collapse in spin-orbit-coupled superconductors under a Zeeman field
    Xusheng Wang, Gaomin Tang, Lianyi He +1
    arXivPreprintarXiv licenceFull textCondensed matterarXiv
  4. Lattice spin systems coupled to a compact U(1) gauge field with negative gauge coupling favoring frustration
    Claudio Bonati, Ettore Vicari
    arXivPreprintarXiv licenceFull textHigh-energy & particle physicsStatistical & nonlinear physicsarXiv
  5. Unconstrained compact lattice QED2+1 coupled to phonons: Gauss sectors, orthogonal semimetal, and deconfined criticality
    João C. Inácio, Fakher F. Assaad
    arXivPreprintarXiv licenceFull textCondensed matterHigh-energy & particle physicsarXiv
BibTeX
@misc{tellkamp2026compact,
  title = {{A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams}},
  author = {Friedjof Tellkamp and David von Stetten and Martin Kollewe},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.21618},
  eprint = {2609.21618},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.21618},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams
AU  - Friedjof Tellkamp
AU  - David von Stetten
AU  - Martin Kollewe
PY  - 2026
DA  - 2026/09/18
PB  - arXiv
DO  - 10.48550/arxiv.2609.21618
UR  - https://arxiv.org/abs/2609.21618
AB  - We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 μm-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 μs transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.
ER  -