Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 55 min ago
PreprintarXiv licencearXiv

Multi-contrast wide-field mid-infrared photothermal imaging

Abstract

Wide-field mid-infrared photothermal (MIP) imaging enables high-speed, chemically specific imaging at sub-micrometer spatial resolution through several possible contrast mechanisms, including scattering change, fluorescence modulation, and phase change. Each mechanism offers distinct advantages, yet existing wide-field MIP instruments have typically been limited to a single contrast mechanism so far, requiring a dedicated instrument for each. Here, we introduce a switchable multi-contrast wide-field MIP microscope that allows the photothermal readout mechanism (based on scattering-, fluorescence-, or quantitative phase imaging (QPI)) to be matched to the sample and imaging conditions. We characterize the spectral fidelity and signal-to-noise (SNR) ratio of each mechanism using 5 μm polystyrene (PS) beads, and the effective spatial resolution using 300 nm PS beads. Scattering- and fluorescence-based detection achieved a sub-500 nm measured point spread function full width at half maximum, while QPI-based detection reached approximately 900 nm but provided up to 26-fold higher SNR than scattering. We further demonstrate imaging across a range of samples, including A549 cells in buffer, mouse lung tissue section, bacteria, and SU8 polymer at 1.4 and 5 μm thickness, with a field of view exceeding 200 μm. Comparison across these samples shows that each contrast mechanism offers distinct trade-offs in resolution, sensitivity, and applicability, guiding readout-strategy selection by sample type. These results establish a flexible, switchable multi-contrast platform for wide-field MIP imaging, with broad applicability across polymer and biological samples.

Related

  1. Infrared Photothermal Heterodyne Imaging in Thermally Thick Medium for Thermo-optic Property Characterizations
    Jordan Letessier, Abel Netter, Jérémie Maire +1
    Journal of Physical Chemistry LettersPeer-reviewedPublisher termsFull textMaterials & polymersApplied physics & instrumentationHAL
  2. Electrically switchable liquid crystal lens for bright-field and spiral phase contrast imaging
    Weiping Ding, Mingyuan Tang, Yubo Liu +3
    Optics ExpressPeer-reviewedPublisher termsMaterials & polymersCrossref
  3. Photochromic Donor–Acceptor Naphthalenediimides Enabling Near‐Infrared Photothermal Conversion for Seawater Desalination
    Sotaro Kusumoto, Soushi Kurihara, Masaya Shimabukuro +5
    Chemistry (Weinheim an Der Bergstrasse, Germany)Peer-reviewedCC BY 4.0Full text1 citedOrganic chemistryPMC
  4. Hybrid Nanocrystalline Theranostic Agents Designed for Magnetic Resonance Imaging, Photothermal, and Photodynamic Therapies Against Cancer
    Yiqian Wang, Pierre Begon de Larouziere, Joana Pereira +13
    Nano SelectPeer-reviewedCC BY 4.0Full text1 citedGeneral chemistryHALHALHAL
  5. Imaging Contrast of Diamond Nanoparticle Structures on Different Supporting Films
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
BibTeX
@misc{raveendran2026multicontrast,
  title = {{Multi-contrast wide-field mid-infrared photothermal imaging}},
  author = {Anooj Thayyil Raveendran and Cornelia Reuter and Samir F. El-Mashtoly and Jürgen Popp and Christoph Kraft},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.18376},
  eprint = {2609.18376},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.18376},
}
RIS
TY  - UNPB
TI  - Multi-contrast wide-field mid-infrared photothermal imaging
AU  - Anooj Thayyil Raveendran
AU  - Cornelia Reuter
AU  - Samir F. El-Mashtoly
AU  - Jürgen Popp
AU  - Christoph Kraft
PY  - 2026
DA  - 2026/09/16
PB  - arXiv
DO  - 10.48550/arxiv.2609.18376
UR  - https://arxiv.org/abs/2609.18376
AB  - Wide-field mid-infrared photothermal (MIP) imaging enables high-speed, chemically specific imaging at sub-micrometer spatial resolution through several possible contrast mechanisms, including scattering change, fluorescence modulation, and phase change. Each mechanism offers distinct advantages, yet existing wide-field MIP instruments have typically been limited to a single contrast mechanism so far, requiring a dedicated instrument for each. Here, we introduce a switchable multi-contrast wide-field MIP microscope that allows the photothermal readout mechanism (based on scattering-, fluorescence-, or quantitative phase imaging (QPI)) to be matched to the sample and imaging conditions. We characterize the spectral fidelity and signal-to-noise (SNR) ratio of each mechanism using 5 μm polystyrene (PS) beads, and the effective spatial resolution using 300 nm PS beads. Scattering- and fluorescence-based detection achieved a sub-500 nm measured point spread function full width at half maximum, while QPI-based detection reached approximately 900 nm but provided up to 26-fold higher SNR than scattering. We further demonstrate imaging across a range of samples, including A549 cells in buffer, mouse lung tissue section, bacteria, and SU8 polymer at 1.4 and 5 μm thickness, with a field of view exceeding 200 μm. Comparison across these samples shows that each contrast mechanism offers distinct trade-offs in resolution, sensitivity, and applicability, guiding readout-strategy selection by sample type. These results establish a flexible, switchable multi-contrast platform for wide-field MIP imaging, with broad applicability across polymer and biological samples.
ER  -